5.Type ip address and the new address. The following screen appears:

Switch> enable

Switch# configure

Switch(config)# ip address 192.168.123.254/24

Switch(config)# end

 

Switch# show ip

: No

Dhcp Client Enabled

IP Address

: 192.108.250.51

Subnet Mask

: 255.255.255.0

Default Gateway

: 192.108.250.5

HTTP Server

: Enabled

HTTP Port

: 80

Switch# write file

 

Writing current-config to startup-config. Please wait.

Configuration saved to startup-config file

It is also acceptable to enter the subnet mask by typing ip address 192.168.123.254/24. Use the show interface veth1 command from privileged mode to see the new IP address. The new IP address automatically writes over the default IP address.

See Chapter 6 for more information on assigning IP addresses to interfaces.

3.5.1 Setting a Default IP Gateway Address

To define the default IP gateway for the switch, insert a static route:

Switch(config)# ip default-gateway 192.168.0.254

3.6 Restoring Factory Defaults

To restore the switch to its factory default settings, follow the commands shown in the following screen.

Switch> enable

 

Switch# reload ?

Reset ALL system parameters except IP parameters to factory

fac-dflt-except-IP

factory-default

default

Reset ALL system parameters to factory default

<cr>

 

The switch is ready for configuration. Refer to the following chapters for management and configuration information.

3.7 System Boot Parameters

The IntraCore IC36240 has two boot banks to store its runtime code. You can select which bank to use for the next boot with the following command:

Switch(config)# boot system flash {bank1bank2}

21

Asante IntraCore IC36240

Setup Guide

Image 21
Contents IntraCore IC36240 Series IntraCore IC36240 Layer 2+ Gigabit Ethernet Switch Setup GuideTable of Contents Connecting to a PC Asante IntraCore IC36240 Introduction FeaturesFront and Back Panel Descriptions Package ContentsLED LEDsConsole Interface Management and ConfigurationHardware Installation and Setup Installation OverviewSafety Overview Recommended Installation Tools Installing into an Equipment RackPower Requirements Environmental RequirementsInstalling the Optional External Power Supply SFP Mini Gbic PortsEquipment Rack Guidelines Connecting Power Connecting to the Network1 10/100/1000BaseT Ports Cabling Procedures Pin Number Pair Number & Wire Colors Gigabit Ethernet Ports Cabling ProceduresAsante IntraCore IC36240 Connecting to a Console Initial Software SetupUser Access Verification Password Connecting to a PCPasswords and Privileges Commands Privileges CommandsEnable Password Service Password-Encryption PasswordConfiguring an IP Address Login SecurityUsername Command Password and login CommandsSystem Boot Parameters Restoring Factory DefaultsSetting a Default IP Gateway Address Switchconfig# ip default-gatewayUser Top User Exec Mode Understanding the Command Line Interface CLIAccess Each Command Mode Document ConventionsCommand Show ? Purpose Privileged Top Privileged Exec ModeGlobal Configuration Mode Switch# configure Command Exit End Ctrl-Z PurposeSpanning-Tree Configuration Mode Interface Configuration ModeAdvanced Features Supported within the Command Mode Vlan Configuration ModeSpanning-tree mst configuration Example of Context Sensitive Help Command Help PurposeSwitch# configure ? Checking Command SyntaxUsing the No and Default Forms of Commands Using CLI Command HistoryUsing Command-Line Editing Features and Shortcuts Keystrokes/Command PurposeMoving Around on the Command Line Completing a Partial Command NameKeystrokes Purpose Editing Command Lines That Wrap Redisplaying the Current Command Line Deleting EntriesScrolling Down a Line or a Screen Transposing Mistyped Characters Controlling CapitalizationKeystrokes Problem Possible Solutions Appendix a Basic TroubleshootingPhysical Characteristics Appendix B SpecificationsEnvironmental Range PerformanceStandards Compliance Technical Support and WarrantyFCC Compliance Statement Important Safety Instructions Appendix C FCC Compliance and Warranty StatementsIntraCare Warranty Statement Appendix D Online Warranty Registration CLI IndexLED