Digi m10 Technical Overview
4.3Temperature Query Response
The Temperature Query Response packet (see Table 4) is sent from the Digi m10 to the host controller, indicating the satellite modem’s temperature in degrees Celsius.
Table 4: Temperature Query Response Packet
0 | 0x05/0x06 | Packet Header | |
|
|
| |
1 | 0x1A | Packet Type | |
|
|
| |
2 | Length0 | Length of the packet | |
|
| ||
|
|
| |
3 | Length1 |
| |
|
|
| |
4 | Retry_count/ Pkt Sequence Number |
| |
|
|
| |
5 | Temp0 | Temperature value in | |
|
| little endian | |
|
| format.(This is a 32 | |
6 | Temp1 | ||
bit floating point | |||
|
| ||
|
| number) | |
7 | Temp2 |
| |
|
|
| |
8 | Temp3 |
| |
|
|
| |
9 | Fletch0 | Fletcher Checksum | |
|
|
| |
10 | Fletch1 |
| |
|
|
|
NOTE: This packet is sent from the Digi m10 to DTE and it contains the current temperature of the Digi m10 in degrees Celsius.
Digi International, Inc. © 2009 | Page 20 of 26 |