Fostex X-24 service manual Playback Frequency Response Calibration, Erase Current Adjustment

Page 11

X-24

3)Playback the TCW-231 test tape and check the output level if it is -10 dBV (0.3 V) ± 1 dB reading.

4)If the reading is not within the above range, adjust R106 ~ R406 on the R/P AMP PCB assy.

3-9. Playback Frequency Response Calibration

1) Set the controls as follows.

Record track select switch: OFF

Dolby B noise reduction on/off switch: OFF

2)Connect an AC volt meter to the TAPE OUT 1 through 4 pin jacks respectively.

3)Playback the TCW-284F test tape and adjust R103 ~ R403 so that the output level at 6.3 kHz is 0.5 dB lower than the 400 Hz output level.

4)Confirm that the output level at 12.5 kHz is within ± 1 dB of the 400 Hz output level.

3-10. Erase Current Adjustment

At adjusting the erase current, put a blank cassette tape to the transport and the track to be adjusted is put in REC mode. Assuming the track 1 to be adjusted, the oscilloscope probe is connected to the test point TP106 on the R/P PCB assy and rotate and fix the core T101 for minimum voltage point. Then, confirm that the voltage at TP105 is more than 55 mV.

NOTE: If the voltage at TP106 is adjusted at minimum, the erase current flowing the erase head is set to the maximum.

Adjust the remaining tracks in the same way.

Track 2: Adjust T201 for minimum voltage at TP206. Then, confirm that the voltage at TP205 is more than 55 mV.

Track 3: Adjust T301 for minimum voltage at TP306. Then, confirm that the voltage at TP305 is more than 55 mV.

Track 4: Adjust T401 for minimum voltage at TP406. Then, confirm that the voltage at TP405 is more than 55 mV.

3-11. Coarse Bias Adjustment

At coarsely adjusting the bias current, put a blank cassette tape to the transport and the track to be adjusted is put in REC mode. Assuming the track 1 to be adjusted, the oscilloscope probe is connected to the test point TP104 on the R/P PCB assy and rotate and fix the pot R133 (220 kΩ) at 60 mV.

Adjust the remaining tracks in the same way.

Track 2: Adjust R233 so that the voltage at TP204 is 60 mV.

Track 3: Adjust R333 so that the voltage at TP304 is 60 mV.

Track 4: Adjust R433 so that the voltage at TP404 is 60 mV.

3-12. Record Level Calibration

*The procedures up to 3-10 must be completed before proceeding to this adjustment.

1)Put a blank cassette tape to the transport and apply a 400 Hz, -10 dBV (0.3 V) sine wave signal to the INPUT 1 and 2 phone jacks. (In the case the signal is input from XLR jack, the terminal No.3 (COLD) and No. 1 (GND) must be shortened.)

2)Set the controls as follows.

Record track select switch: All tracks ON (Confirm that the REC TRK LEDs (1 ~ 4) are blinking.)

Trim knob: At minimum

Dolby B noise reduction on/off switch: OFF

3)Connect an AC volt meter to the TAPE OUT 1 ~ 4 pin jacks.

4)Put the transport into REC PAUSE mode and adjust the Input Fader so that the level at TAPE OUT 1 ~ 4 is -10 dBV (0.3 V).

5)Release the PAUSE button and start recording the signal.

6)After recording a certain length, rewind the tape to the start point of recording section. Then, playback the tape and

check the level at TAPE OUT 1 ~ 4. If the AC volt meter reading is not within -10 dBV (0.3 V) ± 0.5 dB, adjust the pot R121 ~ 421 (22 kΩ) on the R/P PCB assy.

11

Image 11
Contents Model Safety Instructions Table of Contents Mixer Section DefinitionRecorder Section Mixer SectionRecorder Section CONTROLS, Indicators & Connectors Front Panel Routine Maintenance Cleaning HeadDemagnetizing Demagnetizing ProceduresTest Equipment and Adjusting Tools Capstan and pinch rollerTape Speed Check and Adjustment Tape Travel Check and AdjustmentVolume & SW setting Check and Adjusting of Head AzimuthRecord Level Calibration Erase Current AdjustmentCoarse Bias Adjustment Playback Frequency Response CalibrationCross Erasure Measurement Overall Frequency Response Adjustment14. T.H.D. Measurement Erasure MeasurementClick Noise Measurement Sync crosstalk measurement18. S/N Measurement Transport Exploded View & Parts List Table of Adjusting ItemsOverall Exploded View & Parts List Overall Exploded View Transport Exploded View PCB Pattern Drawing Regulator PCBs Mixer PCB Parts ListPCB Jack PCBVT, DSK10C-BT Abbreviation Regulator PCBMixer / Jack PCBs BlockPCB Regulator PCBsREC TRK Block Diagram