Silvercrest KH 2430 manual Malfunction causes and remedies, Two plugs are not touching

Page 26

 

 

 

 

 

Troubleshooting

 

 

 

Malfunction causes and remedies

 

GB

 

 

 

The following chart will assist with the localizing and remedy of minor malfunctions:

 

 

 

 

 

 

Defect

Possible cause

Solution

 

 

 

 

 

 

 

The device is not

Switch the device on.

 

 

 

 

switched on.

 

 

 

 

 

 

 

 

The turntable 5 does

The mains plug is not

Insert the mains plug into the wall

 

 

 

inserted.

socket.

 

 

 

not turn, in spite of the

 

 

 

 

 

 

 

 

fact that the pick-up

The wall socket is not

Check the house fuse.

 

 

 

arm 13 is located in

supplying power.

 

 

 

 

 

 

 

the playback position.

The button "Stop play-

Press the button "Continue

 

 

 

 

 

 

 

 

back" 2 is pressed

 

 

 

 

playback" 4

 

 

 

 

down.

 

 

 

 

 

 

 

 

USB Audio CODEC

The USB cable 8 is not

 

 

 

 

can not be set as

Check the USB cable connection.

 

 

 

connected correctly.

 

 

 

recording source.

 

 

 

 

 

 

 

 

 

No sound can be

Recording source is

Set USB Audio CODEC as

 

 

 

received with the

 

 

 

incorrectly set.

recording source.

 

 

 

Audacity programme.

 

 

 

 

 

 

 

 

Poor sound quality,

Needle 14 is worn out.

Replace the needle.

 

 

 

 

Make sure that the Line-out cable 16

 

 

 

strong noise, sound

Interaction between

 

 

 

blackout

is connected correctly and/or that the

 

 

 

Line-out and USB cable.

 

 

 

 

two plugs are not touching.

 

 

 

 

 

28

USB Record Player KH 2430

Image 26
Contents USB Record Player GB Operating instructions Programme Audacity Operating components Maintenance Removing the cartridgeIndex Preface IntroductionIntroduction Information for these operating instructionsInstructions Limited liabilityEnce and know-how Operator alone bears liability Proper useDamage Safety SafetyBasic Safety Instructions Safety instructions Setting up and connectingSetting up and connecting To the power supply Package contents and transportation inspectionDisposal technology and are therefore recyclable Requirements for the setup locationDisposal of packaging According to the regionally established regulationsConnection to an external amplifier Before initial useElectrical connection ‹ Click on the button Next Installation and configuration of the Programme AudacityConnection to a computer Window License Agreement is shown Installation options is shown On the button NextInstallation directory Device USB Audio Codec Channels 2 StereoLibrary Operating components Operating components see fold out sidesAudacity programme Switching the device on and off Service and operationService and operation Starting the Audacity programmeSetting recording level Operation during playback‹ Start the Audacity programme ‹ Select this menu option again to switch playback offRecording with the Audacity programme Exporting recordings ‹ Click on the button OK. The MP3 file is savedService and operation Installing a new needle MaintenanceMaintenance Removing the cartridge and needleTroubleshooting TroubleshootingCleaning CleaningMalfunction causes and remedies Two plugs are not touchingStorage AppendixStorage/Disposal Disposing of the deviceTechnical data AppendixWarranty ImporterPage USB Record Player KH Mail support.ie@kompernass.com