Hafler 9270, 9180 manual Installation

Page 6
IEC Type 320, 3-wire,with an identical cord.

INSTALLATION

RACK-

MOUNTING

VENTILATION/ PLACEMENT

LINE

VOLTAGE

The 9180/9270 Amplifier is supplied in either a 17” Black Version, or a 19” Silver Version. The 19” model has rackmounting holes provided for installation in equipment racks. The holes are on standard EIA spacings. Due to conflict with adjacent equipment, it may be advisable to remove the four rubber feet from the bottom of the unit. The feet may be removed from the outside, with no dis-assembly of the chassis necessary.

The 9180/9270 Amplifier can produce considerable heat during normal operation. The amplifier should be placed on a hard, smooth surface to allow air to circulate beneath the unit. Additionally, allow at least one inch of free space on either side, and several inches above and behind the amplifier to allow air circulation around the heatsinks. This is particularly important when the unit is installed in a closed cabinet.

In applications where the amplifier is driving low impedance and/or low efficiency loudspeakers at high levels, thermal shutdown may occur if inadequate ventilation is provided. If this occurs, it may be necessary to move the amplifier to a location with better free air circulation.

The amplifier should be located at least several inches away from sensitive components, (such as preamplifiers, tuners, CD players, turntables, etc.) due to the possibility of audible hum or buzz from magnetic radiation.

The 9180/9270 Amplifier is configurable for either 100, 120, 220 or 240 volt operation. This is accomplished by moving the Voltage Selector on the printed circuit board. The procedure is detailed in the section “CHANGING LINE VOLTAGE RATING”.

Make sure that the unit is configured for your local AC line voltage before attempted use. The configuration is labelled directly above the power cord connector.

OPERATION/CONNECTIONS

POWER CORD CONNECTION/ POWER SWITCH

INPUTS

Units wired for 100, 220 and 240 VAC are supplied without power cords. Local agents will supply cords with male connectors appropriate to the local standard.

Units wired for 120 VAC are supplied with a detachable AC power cord. The female connector plugs into the receptacle provided on the rear panel. This power cord is a standard

16 gauge assembly. Should replacement ever be necessary, be sure to replace it

Never remove the grounding pin from the male end of the cord. In applications where a grounded outlet is not available, a ground adaptor should be employed, with the ground tab or wire of the adaptor connected to a suitable earth ground.

The AC power cord of the amplifier must be connected to a receptacle capable of delivering a minimum of 1200 watts. The convenience outlets of some preamplifiers are not rated for this power level. Before connecting the amplifier, be sure to check the rating of such outlets, and take into account the power consumption of any other connected components to determine the total maximum power consumption.

If the amplifier is connected to a component with a switched convenience outlet, then the amplifier’s Power Switch may be left ON at all times, and the power controlled by the switched outlet. If the amplifier is connected to an unswitched outlet, then the amplifier’s power should be controlled by the front panel Power Switch.

All input connections to the amplifier must be performed with the amplifier off!

The left and right audio inputs to the amplifier are via standard RCA jacks. In addition to the printed labelling above the jacks, the channels are identified by RED for right channel, and WHITE for left channel. Connect these jacks to the output of the preamplifier or other signal source.

When operating the amplifier in the Mono Mode, only the left channel input should be used.

-5-

Image 6
Contents Series 9180/ 9270 Power Amplifier Read Instructions Power Cord ProtectionPower Cord Grounding Heed WarningsCleaning Table of Contents Performance Specifications Installation 9180 / 9270 Amplifier Front Panel View 9180 / 9270 Amplifier Rear Panel View Outputs Circuit Highlights Additional Information O U N D Loops Parts List CLEANING/ MaintenanceALL Capacitors in Microfarads 9180 / 9270 Functional Block Diagram SystemNOIlVtl Page ZiRCUIT Schematic Diagram 9180/9270 CiRCUIT Schematic Diagram Service Policy and Limited Warranty