NOTICE - IMPORTANT SAFETY INFORMATION

Ap!!!J!A

WARNING: TO PREVENT FIRE OR

SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

1 . READ INSTRUCTIONS

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and mainte- nance (servicing) instructions in the literature accompanying the appliance .

All the safety and operating instructions of your Hafler equipment should be read before power is applied to the equipment.

2.

3.

4.

5.

RETAIN OWNERS MANUAL

These safety and operating instructions should be retained for future reference.

HEED WARNINGS

All warnings on the equipment and in the operating instructions are important and should be followed.

FOLLOW INSTRUCTIONS

All operating and use instructions are important and should be followed.

HEAT

The equipment should be kept away from areas of high temperature, such as heater vents, radiators, stoves/ovens, fireplaces, etc.

6 . VENTILATION

The equipment should be used in an area suitable for proper ventilation. Care should be taken not to impede airflow in and around the cabinet. Do not mount on a carpeted shelf or in a sealed enclosure. Allow for proper clearance above the equipment.

7 . WATER AND MOISTURE

The equipment should not be used in or around water, such as a bathtub, sink, or swimming area. Also, the equipment should not be used in areas prone to flooding, such as a basement.

8 . POWER SOURCES

The equipment should be connected only to a power source of the same voltage and frequency as that listed on the rear panel above the power cord entry point.

9 . POWER CORD PROTECTION

Power cords should be arranged so that they do not interfere with the movement of objects in the room: people, fan blades, utility carts, etc. Also, care should be taken that the cord is not pinched or cut, and placed so that it is not in danger of being pinched or cut, as in under a rug, around a tight corner, etc.

10.POWER CORD GROUNDING

The power supply cord is of a three wire grounded type, designed to reduce the risk of electric shock sustained from a live cabinet. It is assumed to be of suitable length for most uses of the equipment. The use of extension cords and power strips is discouraged unless they are of suitable rating to deliver the required total current for safe operation of all connected equipment. Furthermore, extension cords or power strips must provide the same three wire grounded connection. It is important that the blades of the equipment’s plug be able to fully insert into the mating receptacle.

Never remove the round grounding pin on the plug in an attempt to mate to a two wire ungrounded receptacle: use a grounding adaptor with the grounding tab or wire suitably connected to earth ground.

-l-

Image 2
Contents Series Power Cord Grounding Power SourcesPower Cord Protection Read InstructionsNON-USE Periods CleaningDamage Requiring Service Object and Liquid EntryTable of Contents Performance Specifications General InformationInstallation OPERATION/CONNECTIONSAmplifier Front Panel View Page Outputs Circuit Highlights Additional InformationAdjusting Bias Ground O P S CLEANING/ Maintenance Functional Block Diagram Parts List ’L wc4 Replage only with Same Type and Rating Fuses F4 AMP Circuit Schematic Diagram YIT Service Policy and Limited Warranty

9130 specifications

The Hafler 9130 is a powerful and versatile two-channel power amplifier, designed to deliver exceptional audio performance for both professional and home audio applications. Known for its robust build quality and high-efficiency design, the Hafler 9130 is ideal for audiophiles and sound engineers who demand the best in sound reproduction.

One of the key features of the Hafler 9130 is its unique MOSFET output stage. This technology benefits sound reproduction by minimizing distortion while providing a smooth, natural tonal balance. The amplifier can produce a significant amount of power, offering up to 130 watts per channel into an 8-ohm load, and even more into 4 ohms. This capability ensures that the Hafler 9130 can drive a wide range of speakers, making it suitable for various audio setups.

In addition to its powerful performance, the Hafler 9130 integrates sophisticated circuit design, such as a high-quality balanced input stage. This feature allows for reduced noise and interference, resulting in a cleaner audio signal. The amplifier also incorporates a sophisticated thermal protection circuit, which automatically disconnects the output if the unit overheats, preventing damage and enhancing longevity.

Another prominent characteristic of the Hafler 9130 is its efficient heat dissipation system. Featuring large heat sinks and a well-ventilated chassis, the amplifier remains cool even during demanding playback situations. This design not only preserves the integrity of the components but also enhances the overall performance.

The Hafler 9130 is designed with an intuitive user interface, featuring recessed volume controls and a power switch that make operation straightforward. Additionally, the amplifier's versatile connectivity options include RCA and XLR inputs, allowing it to pair seamlessly with various audio sources.

Overall, the Hafler 9130 stands out as a reliable and high-performance amplifier. Its combination of advanced technologies, robust design, and user-friendly features make it a popular choice among enthusiasts and professionals alike. Whether used in a studio setting or a home theater, the Hafler 9130 delivers a powerful and dynamic audio experience that truly brings music and sound to life.