Sony NSP-100 manual Precautions, Alarm Indications

Page 26

Others

Precautions

On operation and storage locations

Avoid operation or storage in any of the following places.

Location subject to extremes of temperature (operating temperature range 5°C to 40°C (41°F to 104°F))

Location subject to direct sunlight for long periods, or close to heating appliances (Note that the interior of a

car left in summer with the windows closed can exceed 50°C (122°F).)

Damp or dusty places

Location subject to severe vibrations

Location near equipment generating strong electromagnetic emissions

Location near transmitting stations generating strong radio waves

Operate the unit in a horizontal position

This unit is designed to be operated in a horizontal position. Do not operate it on its side, or tilted through an excessive angle (exceeding 20°).

Dropping the unit, or otherwise imparting a violent shock to it, is likely to cause it to malfunction.

Avoid violent impacts

Dropping the unit, or otherwise imparting a violent shock to it, is likely to cause it to malfunction.

Do not obstruct ventilation openings

To prevent the unit from overheating, do not obstruct ventilation openings, by for example wrapping the unit in a cloth while it is in operation.

On cleaning

If the casing or panel is dirty, wipe it gently with a soft dry cloth. In the event of extreme dirt, use a cloth steeped in a neutral detergent to remove the dirt, then wipe with a dry cloth. Applying alcohol, thinners, insecticides, or other volatile solvents may result in deforming the casing or damaging the finish.

On repacking and shipping

Save the original shipping carton and packing material; they will come in handy if you ever have to ship your unit.

For maximum protection, repack your unit as it was originally packed at the factory, and take care not to impart violent shocks in transit.

Alarm Indications

The temperature range for guaranteed operation of this unit is from 5°C to 40°C (41°F to 104°F). If operated outside this temperature range, the life of the unit may be reduced, or the internal hard disk drive may fail. The following alarm icons appear at the lower left of the menu screen to indicate an abnormal temperature within the unit or other problems.

Indication Meaning and action to take

High temperature warning

The internal temperature has risen into the range

65°C to 79°C (149°F to 174°F).

g• Check that the ventilation openings in the upper and lower surfaces are not obstructed.

Check the ambient temperature.

High temperature fault

The internal temperature has risen to 80°C (176°F) or above.

g• Check that the ventilation openings in the upper and lower surfaces are not obstructed.

Check the ambient temperature.

Low temperature warning

The internal temperature has fallen into the range

1°C to 5°C (34°F to 41°F).

gCheck the ambient temperature.

Low temperature fault

The internal temperature has fallen to 0°C (32°F) or below.

gCheck the ambient temperature.

Hard disk drive warning

The internal hard disk is failing. Replace it as soon as possible.

gConsult your supplier or Sony service representative.

Hard disk drive fault

The internal hard disk has failed, and must be replaced.

gConsult your supplier or Sony service representative.

Fan stopped

The internal fan has stopped.

If this is not corrected, it may lead to excessive internal temperatures.

gConsult your supplier or Sony service representative.

Remote controller not accepted

The unit cannot be operated from a remote controller.

(For example when under the control of the BZNP-100 Software)

26

Precautions / Alarm Indications

Image 26
Contents Network Player For the customers in the USA For the customers in EuropeTable of Contents Features High Image QualityNames and Functions of Parts Main Unit Front Panel and Left SideMain Unit Rear Panel Remote Controller While playback is paused Pressing this button ENTER/b, B, v, V controlStop button Replacing the Battery Remote Controller PreparationsMain Unit DIP Switch and Remote Controller Settings PreparationsStarting Up and Initial Settings To return to the previous screenTo exit the Menu screen Alarm indicationsDisplaying the Menu Screen Play button playback Automatic playback at power onPlaying a Playlist To stop during playbackTo change Playing a Movie FileDisplaying a Still Image File When a password has been set Deleting an Unwanted PlaylistDeleting Unwanted Movie and Still Image Files To exit the Setup screen Displaying the Setup ScreenSetting the System Date and Time Making the Store Playout Log Setting Making the Delete Confirmation SettingMaking the Display During Break Setting To remove an existing setting Carrying Out Playout Mode Setup PlaylistsCarrying Out Screen Adjustment To cancel the adjustment and exit the menu screen System Administrator SetupAdjustment procedure When a password has been setSettings selected in the System Administrator Setup screen Carrying Out Network SetupCarrying Out RS-232C Setup Setting Menu Language Carrying Out Delete All Data Carrying Out Password SetupActivating Automatic Delete To correct an entryTo cancel the password Connecting the Power Examples of System ConnectionPage Precautions Alarm IndicationsOthers SpecificationsAudio outputs Sony Corporation