Temperature

 

Operating

10° to 35°C (50° to 95°F) with a maximum

 

temperature gradation of 10°C per hour

 

NOTE: For altitudes above 2950 feet, the maximum

 

operating temperature is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum

 

temperature gradation of 20°C per hour

Relative humidity

 

Operating

8% to 85% (noncondensing) with a maximum

 

humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

 

Operating

0.25 G at 3–200 Hz for 15 min

Storage

0.5 G at 3–200 Hz for 15 min

Maximum shock

 

Operating

One shock pulse in the positive z axis (one pulse

 

on each side of the system) of 31 G for 2.6 ms in

 

the operational orientation

Storage

Six consecutively executed shock pulses in the

 

positive and negative x, y, and z axes (one pulse on

 

each side of the system) of 71 G for up to 2 ms

Altitude

 

Operating

–16 to 3,048 m (–50 to 10,000 ft)

 

NOTE: For altitudes above 2950 feet, the maximum

 

operating temperature is derated 1ºF/550 ft.

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Airborne Contaminant Level

 

Class

G2 or lower as defined by ISA-S71.04-1985

 

 

Getting Started With Your System

11

Image 13
Contents Getting Started With Your System Dell PowerEdge T710 SystemsGuide de mise en route Primeiros passos com o sistema Procedimientos iniciales con el sistemaPage Model E04S Regulatory type E04S001 Getting Started With Your SystemMarch Notes, Cautions, and WarningsP/N N732H Stabilizing the Tower System Installation and ConfigurationConnecting the Power Cables Optional - Connecting the Keyboard, Mouse, and MonitorTurning On the System Securing the Power CablesSupported Operating Systems Complete the Operating System SetupOther Information You May Need Obtaining Technical Assistance Technical Specifications2x 25W cards and 4x 15W cards may be installed at registered or unbuffered Error Correcting CodeUp to sixteen 2.5-inch, hot-swap SAS/SATA/SSD NOTE 3.5-inch SSD is supported using 2.5-inchinternal drives or up to eight 3.5-inch, hot-swap One optional flash memory card slot on internalUnder typical line conditions and over the entire Matrox G200eW video controller VGA connectorpositive and negative x, y, and z axes one pulse on Getting Started With Your System Guide de mise en route Systèmes Dell PowerEdge T710Modèle E04S Type réglementaire E04S001 Remarques, précautions et avertissements Stabilisation dun système en tour Installation et configurationBranchement du ou des câbles dalimentation Facultatif - Connexion du clavier, de la souris et du moniteurMise sous tension du système Fixation du ou des câbles dalimentationSystèmes dexploitation pris en charge Terminez linstallation du système dexploitationAutres informations utiles Spécifications techniques Obtention dune assistance techniqueBarrettes de mémoire ECC code de correction REMARQUE Possibilité dinstaller un disqueJusquà seize disques internes SAS/SATA/SSD 2,5 pouces, échangeables à chaud ou jusquàConnecteur DTE à 9 broches, compatible de fonctionnement est réduite de 0,55C 1F REMARQUE Pour les altitudes supérieures àgradient thermique maximal de 20 C par heure De 8 % à 85 % sans condensation avec uneEnvironnement suite Primeiros passos com o sistema Dell PowerEdge Sistemas T710Modelo E04S Tipo de regulamentação E04S001 Notas, Avisos e Advertências Estabilização do sistema em torre Instalação e configuraçãoConexão dos cabos de alimentação Opcional - Conexão de teclado, mouse e monitorDobre os cabos de alimentação do sistema em forma de laço conforme apresentado na ilustração e prenda-os com a tira fornecida Ativação do sistemaSistemas operacionais compatíveis Conclua a configuração do sistema operacionalOutras informações úteis Especificações técnicas Como obter assistência técnicaNOTA É possível alocar no máximo 110W para placas de complementos. Todos os slots suportamcorreção de erro Error Correcting Code, ECC Conector DTE de 9 pinos, compatível com Quatro conectores RJ-45 para placas de redeDuas unidades de 4 pinos, compatível com USB Sob condições de linha típicas e dentro da faixa10 C a 35 C com variação máxima de 10 C Bateria do tipo moeda, de íon de lítio, CRa temperatura de operação máxima é avaliada 40 C a 65 C -40 to 149F com variaçãoAmbientais continuação Procedimientos iniciales con el sistema Sistemas Dell PowerEdge T710Modelo E04S Tipo reglamentario E04S001 Notas, precauciones y avisos Estabilización del sistema de torre Instalación y configuraciónConexión de los cables de alimentación Conexión del teclado, el ratón y el monitor opcionalEncendido del sistema Fijación de los cables de alimentaciónSistemas operativos admitidos Finalización de la configuración del sistema operativoOtra información útil Información de la NOM sólo para México Obtención de asistencia técnica100-240 V CA NOTA Las tarjetas adicionales tienen asignado un Especificaciones técnicasmáximo de 110 W. Todas las ranuras admiten hasta 25 W, pero se pueden instalar un máximo de dosHasta 16 unidades SAS, SATA o SSD internas la conexión puede alcanzar 25 A por cada fuente Controladora de vídeo Matrox G200eW conectorun choque en cada lado del sistema de 31 G Un choque en el sentido positivo del eje zdurante 2,6 ms en la orientación de funcionamiento