Dell
Table 4. | 750W Power Supply Specifications |
|
|
AC Power Supply (per power supply) | |
|
|
Wattage | 750W (optional redundant) |
|
|
Voltage | |
|
|
Maximum inrush current | Under typical line conditions and over the entire system |
| ambient operating range, the inrush current may reach 55A per |
| power supply for 10ms or less |
|
|
The R515 Energy Smart 750W Power Supply is certified Gold (80 Plus) and Climate Savers 3. It is certified UL approved and incorporates PFC logic.
4.3 Heat Dissipation
Redundant power supply (8 hard drive chassis): 2200 BTU/hr maximum
Redundant power supply (12 hard drive chassis): 2450 BTU/hr maximum
4.4 Environmental Specifications
Table 5 details the environmental specifications for operating and storage of the PowerEdge R515.
| Table 5. Environmental Specifications | |
|
|
|
Temperature |
|
|
|
|
|
Operating |
| 10° to 35°C (50° to 95°F) with a maximum temperature |
|
| gradation of 10°C per hour |
|
| Note: For altitudes above 2950 feet, the maximum operating |
|
| temperature is derated 1°F/550 ft. |
|
|
|
Storage |
| |
|
| gradation of 20°C per hour |
|
|
|
Relative Humidity |
|
|
|
|
|
Operating |
| 20% to 80% (noncondensing) with a maximum humidity gradation |
|
| of 10% per hour |
|
|
|
Storage |
| 5% to 95% (noncondensing) with a maximum humidity gradation |
|
| of 10% per hour |
|
|
|
Maximum Vibration |
|
|
|
|
|
Operating |
| 0.26 Grms at |
|
|
|
Storage |
| 1.87 Grms at |
|
|
|
Maximum Shock |
|
|
|
|
|
Operating |
| One shock pulse in the positive z axis (one pulse on each side of |
|
| the system) of 31G for 2.6ms in the operational orientation |
|
|
|
Storage |
| Six |
|
| negative x, y, and z axes (one pulse on each side of the system) |
|
| of 71G for up to 2ms |
|
| Square wave shock of 32G @ 270 in/second |
|
|
|
24
PowerEdge R515 Technical Guide