BTU Specifications

Specification

Value

 

 

Power Supply Voltage Range

200V - 240 Vac

 

 

Power Supply

Four

 

 

Power Supply BTU

14334.6 BTU/hr

 

 

Power Supply: Power (W)

4200

 

 

PCI Slots

16

 

 

Drives

16 GPGPU

 

 

Drives Type

NVIDIA GPGPU

 

 

Processor: Sockets

N/A

 

 

Processor Cores

N/A

 

 

Weight (kg): Empty

30 kg (only chassis)

 

 

Weight (kg): Typical

45 kg (L6 system)

 

 

Weight (kg): Loaded

56 kg (full system)

 

 

Weight (Ibs): Empty

66 lbs (only chassis)

 

 

Weight (Ibs): Typical

99 lbs (L6 system)

 

 

Weight (Ibs): Loaded

123 lbs (full system)

 

 

Environmental Specifications

Specification

Value

 

 

 

Operating: 10°C to 35°C

Temperature range

 

 

Non-Operating: -40°C to -60°C

 

 

 

Operating: 20–80% RH

 

Humidity (non-condensing)

 

 

 

 

Non-Operating: 20–95% RH

 

 

11

Image 13
Contents Dell PowerEdge C410x Page Dell PowerEdge C410x Getting Started With Your System NF0DD Page Unpack your system Installation and ConfigurationInstalling the Rails and System in a Rack Page Install the system into the rack Connecting iPass Cables Page Chassis Other Information You May Need Technical SpecificationsFront I/O Board Power SupplyFAN Module BTU Specifications Page Dell PowerEdge C410x Guide de mise en route du système Remarques, précautions et avertissements Page Déballage de votre système Installation et configurationInstallation des rails et du système dans un rack Page Installez le système dans le rack Connexion des câbles iPass Page Caractéristiques techniques Autres informations utilesChâssis Module du Ventilateur Panneau dE-S avantBloc dalimentation Caractéristiques des modules BTU Page Dell PowerEdge C410x Primeiros passos Com o sistema Notas, Avisos e Advertências Page Desembale o sistema Instalação e configuraçãoComo instalar os trilhos e o sistema no rack Page Instale o sistema no rack Como conectar cabos iPass Page Especificações técnicas Outras informações úteisChassi Módulo FAN Ventilador Painel frontal de E/SFonte de alimentação Especificações de BTU Page Dell PowerEdge C410x Procedimientos iniciales con el sistema Notas, precauciones y avisos Page Desembalaje del sistema Instalación y configuraciónInstalación de los rieles y del sistema en un rack Page Instale el sistema en el rack Conexión de los cables iPass Page Información de la NOM sólo para México Otra información útil que puede necesitarChasis Especificaciones técnicasPlaca frontal de E/S Fuente de alimentación Módulo de ventiladorEspecificaciones ambientales