CAUTION: To reduce the risk of electric shock, this system should only be serviced by qualified service personnel.
Restricted Access Location
The Dell PowerEdge C410X system is intended for installation only in restricted access locations as defined in Cl. 1.2.7.3 of IEC
1.2.7.3RESTRICTED ACCESS LOCATION: A location for equipment where both of the following paragraphs apply:
•Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken.
•Access is through the use of a TOOL or lock and key, or other means of security, and is controlled by the authority responsible for the location.
CAUTION: To prevent the system PSUs from overloading and to ensure the optimum system performance and stability, always follow the table below for PSU and GPGPU configuration.
Minimum PSU Quantity | Maximum GPGPU Quantity |
|
|
1 | 4 |
|
|
2 | 8 |
|
|
3 | 16 |
|
|
The fourth PSU is redundant.