FieldServer FS-8700-64 instruction manual Revision Control, Pmc

Page 21

FS-8700-64 ATMI ACM

Page 20 of 22

7. Revision Control

Date

Rev

Resp

Description

 

 

 

1.01a Rev1

PMC

This revision and all previous revisions did not have a

 

 

 

revision control section.

 

1.01a Rev

PMC

This issue of the manual corresponds to the release of

 

2

 

driver version 1.01a in which functionality was added to

 

 

 

store the current port sample’s data separately.

 

 

 

The following sections of this manual have been

 

 

 

amended.

 

 

 

 

 

Section 1.

 

Driver previously described as

 

 

 

 

client /server.

 

 

 

 

Section 4.4.2

New keyword

 

 

 

Section 4.4.4

Title Changed

 

 

 

Section 4.4.5

New example

 

 

 

Section 6.1

 

Amended

 

 

 

Section 6.4 Error messages 9,10,11 added.

 

 

 

 

 

 

 

1.01b Rev

 

Section 4.4.2

New keyword

 

0

 

Section 4.4.6

New example

 

 

 

Section 6.1

 

Amended

 

 

 

Section 6.3

 

New stats 20-22

 

 

 

Section 6.4 Amended notes for msg #9.

 

 

 

Section 6.7

 

New Section

 

101c Rev0

 

Section 4.4.5

Corrections and additional notes to

 

 

 

 

 

describe storage of gas values

 

 

 

 

 

based on sample number.

 

 

 

Section 6.8 New notes on scaling. Prior to revision

 

 

 

1.01c of the driver this feature did not operate and all

 

 

 

values were stored 100 times too large.

 

102a Rev0

 

Section 4.4.2

New valid keywords for ATMI_Data

 

 

 

 

 

parameter. “port-combo” and “slot-

 

 

 

 

 

combo”

 

 

 

Section 4.4.4

Modified example to illustrate use

 

 

 

 

 

of “…-combo” keywords.

 

 

 

Section 6.9 New section on ATMI_Data parameter.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 21
Contents Effective for all systems manufactured after May 1 FS-8700-64 Atmi ACMTable of Contents Provided by user Atmi ACM DescriptionFS-8700-64 Atmi ACM FieldServerAtmi ACM Panel Hardware ConnectionsData Arrays Configuring the FieldServer as a Atmi ACM ClientSection Title Column Title Function Legal ValuesClient Side Connections Default 1 secondFS-8700-64 Atmi ACM Example AtmiClient Side Nodes Client Side Map DescriptorsPassive Gas-value, == Port-values MAP1 Page Page Page Driver Notes Data position in the Data Arrays Configuring the FieldServer as a Atmi ACM ServerExposing Driver Stats Driver StatsContents Driver Error Messages FS-8700-64 Atmi ACM Timeouts Demand & Lock ScanMalfunctions Malfunction Major Type Mafunction Minor Type Alarms and/or WarningsGas Values & Scaling TemplowComposite Validation Scan vs Normal Slot Scan Current SlotPMC Revision ControlTOC DNCJDM

FS-8700-64 specifications

The FieldServer FS-8700-64 is a powerful and versatile communication gateway designed to facilitate the integration of various building automation and industrial control networks. It serves as a bridge between disparate systems, enabling seamless interoperability and enhanced data exchange among multiple protocols. This makes the FS-8700-64 an essential tool for modern facilities seeking to optimize operations and improve efficiency.

One of the standout features of the FS-8700-64 is its support for a wide array of communication protocols. This includes popular standards such as BACnet, Modbus, LonWorks, and more. Such compatibility allows users to connect legacy systems with modern technology seamlessly. The device can convert data formats, ensuring that information flows smoothly between systems that otherwise would have been isolated.

The FS-8700-64 is equipped with a robust processing unit that guarantees high performance and reliability. This allows it to handle large volumes of data in real-time, making it suitable for complex environments where fast and accurate information exchange is critical. Furthermore, it features extensive memory capacity, enabling users to store significant amounts of data for both immediate analysis and historical reference.

In addition to its hardware capabilities, the FS-8700-64 leverages advanced software technologies to enhance functionality. The device’s configuration can be managed through an intuitive web interface, simplifying setup and ongoing maintenance. Users can easily customize settings, monitor system performance, and troubleshoot issues without requiring specialized expertise.

The FS-8700-64 also emphasizes security, a vital consideration in today’s interconnected landscape. The device is designed with features to safeguard communications against unauthorized access and cyber threats, ensuring a secure operating environment for sensitive data.

Another significant advantage of the FS-8700-64 is its scalability. The modularity of the device allows for easy upgrades and expansions to meet growing operational demands. As businesses evolve, the FS-8700-64 can adapt, ensuring continued performance and functionality well into the future.

In summary, the FieldServer FS-8700-64 is an indispensable communication gateway for organizations looking to streamline their building automation and industrial control systems. With its extensive protocol support, robust performance, user-friendly software, and strong security features, it stands as a leading choice for achieving efficient and integrated operations across various environments.