6.5Timeouts

See section 4.2 for information on how timeouts should be specified.

Occasional timeouts may be expected when there are noisy messages or if the ACM device has been locked. Timeouts do not stop the driver processing the next valid screen of data.

6.6Demand & Lock Scan

The driver can process data from demand and locked scans. Incoming data is processed in the same way as normal scans and stored using the same map descriptors.

6.7Malfunctions

The driver can process malfunctions reported by the ACM unit.

When a malfunction is cleared then the driver sets all (1st 100) of the malfunction data array elements to zero A malfunction is considered cleared when a normal scan is processed.

When a malfunction is recognized the driver stores data in the following locations.

1st Element : Major type of the malfunction ( as a number )

2nd Element : Minor type of the malfunction. (as a number )

And

Element x : Value set to 1.

X = major * 10 + minor

This additional data element is provided so that relays / indicating lamps in a downstream device can be set without additional logic.

The driver uses the keyword ‘MALFUNCTION’ to recognize ACM malfunctions. If the ACM firmware is changed and this keyword is no longer produced then the driver will no longer recognize malfunctions.

If the driver recognizes that there is a malfunction but cannot interpret the malfunction type then the major and/or minor types are set to a value of 99 and element x is not set at all.

The table below shows malfunction’s major and minor types.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 18
Contents FS-8700-64 Atmi ACM Effective for all systems manufactured after May 1Table of Contents FS-8700-64 Atmi ACM Atmi ACM DescriptionProvided by user FieldServerHardware Connections Atmi ACM PanelSection Title Configuring the FieldServer as a Atmi ACM ClientData Arrays Column Title Function Legal ValuesFS-8700-64 Atmi ACM Example Default 1 secondClient Side Connections AtmiClient Side Nodes Client Side Map DescriptorsPassive Gas-value, == Port-values MAP1 Page Page Page Configuring the FieldServer as a Atmi ACM Server Driver Notes Data position in the Data ArraysDriver Stats Exposing Driver StatsContents Driver Error Messages FS-8700-64 Atmi ACM Timeouts Demand & Lock ScanMalfunctions Gas Values & Scaling Alarms and/or WarningsMalfunction Major Type Mafunction Minor Type TemplowCurrent Slot Composite Validation Scan vs Normal Slot ScanRevision Control PMCTOC DNCJDM

FS-8700-64 specifications

The FieldServer FS-8700-64 is a powerful and versatile communication gateway designed to facilitate the integration of various building automation and industrial control networks. It serves as a bridge between disparate systems, enabling seamless interoperability and enhanced data exchange among multiple protocols. This makes the FS-8700-64 an essential tool for modern facilities seeking to optimize operations and improve efficiency.

One of the standout features of the FS-8700-64 is its support for a wide array of communication protocols. This includes popular standards such as BACnet, Modbus, LonWorks, and more. Such compatibility allows users to connect legacy systems with modern technology seamlessly. The device can convert data formats, ensuring that information flows smoothly between systems that otherwise would have been isolated.

The FS-8700-64 is equipped with a robust processing unit that guarantees high performance and reliability. This allows it to handle large volumes of data in real-time, making it suitable for complex environments where fast and accurate information exchange is critical. Furthermore, it features extensive memory capacity, enabling users to store significant amounts of data for both immediate analysis and historical reference.

In addition to its hardware capabilities, the FS-8700-64 leverages advanced software technologies to enhance functionality. The device’s configuration can be managed through an intuitive web interface, simplifying setup and ongoing maintenance. Users can easily customize settings, monitor system performance, and troubleshoot issues without requiring specialized expertise.

The FS-8700-64 also emphasizes security, a vital consideration in today’s interconnected landscape. The device is designed with features to safeguard communications against unauthorized access and cyber threats, ensuring a secure operating environment for sensitive data.

Another significant advantage of the FS-8700-64 is its scalability. The modularity of the device allows for easy upgrades and expansions to meet growing operational demands. As businesses evolve, the FS-8700-64 can adapt, ensuring continued performance and functionality well into the future.

In summary, the FieldServer FS-8700-64 is an indispensable communication gateway for organizations looking to streamline their building automation and industrial control systems. With its extensive protocol support, robust performance, user-friendly software, and strong security features, it stands as a leading choice for achieving efficient and integrated operations across various environments.