Maxtor 90840D7, 90910D8, 90875D7, 91000D8, 90500D4 Shock and Vibration, Reliability Specifications

Page 15

PRODUCT SPECIFICATIONS

Shock and Vibration

PARAMETER

OPERATING

NON-OPERATING

 

 

 

Mechanical Shock

20 Gs, 2.0 ms, no errors

200 Gs, 2.0 ms, no damage

Random Vibration

10 - 300 Hz at 0.004 G2/Hz

10 Hz at 0.015 G2/Hz

 

301 - 500 Hz at 0.0006 G2/Hz

40 Hz at 0.015 G2/Hz

 

 

500 Hz at 0.00015 G2/Hz

Swept Sine Vibration

 

 

5 - 20 Hz

0.049 inches double amplitude

 

21 - 300 Hz

1.0 G peak amplitude (0 - peak)

 

Reliability Specifications

AFR

 

< 1.7%

The annualized average failure rate (AFR) applies to the period prior

 

to the expiration of component design life, and is based on failures

 

chargeable to Maxtor.

MTBF

 

> 500,000 hours

Maxtor does not differentiate between various usage profiles (e.g.,

 

power-on hours, power saving modes, non-operating periods or

 

operating temperatures within the published specification.)

Quality Acceptance Rate

 

TBD (< 1,500 DPPM)

The quality acceptance rate indicates the percentage of Maxtor

 

products successfully installed by our customers, and/or the number

 

of defective parts per million (DPPM) encountered during the entire

 

installation process.

Start/Stop Cycles

 

50,000 (minimum)

This indicates the minimum cycles for reliable start/stop function at a

 

≥ 60% confidence level.

Data Reliability

 

< 1 per 1014 bits read

Data errors (non-recoverable). Average data error rate allowed with all

 

error recovery features activated.

Component Design Life

 

5 years (minimum)

Component design life is defined as a.) the time period before

 

identified wear-out mechanisms impact the failure rate, or b.) the time

 

period up to the wear-out point when useful component life expires.

3 – 10

Image 15
Contents DiamondMaxPlus2500 Revisions Manual No U T I O N Before You BeginAbbreviations IntroductionMaxtor Corporation Manual OrganizationNumbering Signal ConventionsConventions Key WordsProduct Description DiamondMax Plus 2500 Key FeaturesFunctional / Interface Product FeaturesSoftware ECC Correction On-the-Fly Hardware Error Correction Code ECCLogical Block Addressing Defect Management Zone DMZAutomatic Write Reallocation AWR Read-Ahead ModeCache Management Buffer SegmentationMajor HDA Components Dual Drive Support Subsystem ConfigurationJumper Location/Configuration Cylinder LimitationModels and Capacities Product SpecificationsDrive Configuration Performance SpecificationsPhysical Dimensions Environmental Limits Power Requirements AveragePower Mode Definitions EPA Energy Star ComplianceShock and Vibration Reliability SpecificationsSafety Regulatory Compliance Radiated Electromagnetic Field Emissions EMC ComplianceCanadian Emissions Statement Important Notice Handling and InstallationHard Drive Handling Precautions Pre-formatted DriveMulti-pack Shipping Container Unpacking and InspectionPhysical Installation Recommended Mounting ConfigurationRepacking Important Please Read Before You BeginHard Drive Identification General RequirementsMounting Drive in System Systems Using Cable SelectAttaching System Cables Attaching Interface and Power CablesSetting the Bios Cmos System SetupHard Drive Preparation How to Obtain MaxBlast Software System Hangs During Boot