PRODUCT SPECIFICATIONS
Shock and Vibration
PARAMETER | OPERATING |
|
|
|
|
Mechanical Shock | 20 Gs, 2.0 ms, no errors | 200 Gs, 2.0 ms, no damage |
Random Vibration | 10 - 300 Hz at 0.004 G2/Hz | 10 Hz at 0.015 G2/Hz |
| 301 - 500 Hz at 0.0006 G2/Hz | 40 Hz at 0.015 G2/Hz |
|
| 500 Hz at 0.00015 G2/Hz |
Swept Sine Vibration |
|
|
5 - 20 Hz | 0.049 inches double amplitude |
|
21 - 300 Hz | 1.0 G peak amplitude (0 - peak) |
|
Reliability Specifications
AFR |
|
< 1.7% | The annualized average failure rate (AFR) applies to the period prior |
| to the expiration of component design life, and is based on failures |
| chargeable to Maxtor. |
MTBF |
|
> 500,000 hours | Maxtor does not differentiate between various usage profiles (e.g., |
| |
| operating temperatures within the published specification.) |
Quality Acceptance Rate |
|
TBD (< 1,500 DPPM) | The quality acceptance rate indicates the percentage of Maxtor |
| products successfully installed by our customers, and/or the number |
| of defective parts per million (DPPM) encountered during the entire |
| installation process. |
Start/Stop Cycles |
|
50,000 (minimum) | This indicates the minimum cycles for reliable start/stop function at a |
| ≥ 60% confidence level. |
Data Reliability |
|
< 1 per 1014 bits read | Data errors |
| error recovery features activated. |
Component Design Life |
|
5 years (minimum) | Component design life is defined as a.) the time period before |
| identified |
| period up to the |
3 – 10