Maxtor 90625D5, 90910D8, 90840D7, 90875D7, 91000D8 Key Words, Numbering, Signal Conventions

Page 5

DIAMONDMAX PLUS 2500 – INTRODUCTION

Conventions

If there is a conflict between text and tables, the table shall be accepted as being correct.

Key Words

The names of abbreviations, commands, fields and acronyms used as signal names are in all uppercase type (e.g., IDENTIFY DRIVE). Fields containing only one bit are usually referred to as the “name” bit instead of the “name” field.

Names of drive registers begin with a capital letter (e.g., Cylinder High register).

Numbering

Numbers that are not followed by a lowercase “b” or “h” are decimal values. Numbers that are followed by a lowercase “b” (e.g., 01b) are binary values. Numbers that are followed by a lowercase “h” (e.g., 3Ah) are hexadecimal values.

Signal Conventions

Signal names are shown in all uppercase type.

All signals are either high active or low active signals. A dash character (-) at the end of a signal name indicates that the signal is low active. A low active signal is true when it is below ViL and is false when it is above ViH. A signal without a dash at the end indicates that the signal is high active. A high active signal is true when it is above ViH and is false when it is below ViL.

When a signal is asserted, it means the signal is driven by an active circuit to its true state.

When a signal is negated, it means the signal is driven by an active circuit to its false state.

When a signal is released, it means the signal is not actively driven to any state. Some signals have bias circuitry that pull the signal to either a true or false state when no signal driver is actively asserting or negating the signal. These instances are noted under the description of the signal.

1 – 5

Image 5
Contents DiamondMaxPlus2500 Revisions Manual No U T I O N Before You BeginMaxtor Corporation IntroductionManual Organization AbbreviationsConventions Signal ConventionsKey Words NumberingProduct Description DiamondMax Plus 2500 Key FeaturesFunctional / Interface Product FeaturesLogical Block Addressing On-the-Fly Hardware Error Correction Code ECCDefect Management Zone DMZ Software ECC CorrectionCache Management Read-Ahead ModeBuffer Segmentation Automatic Write Reallocation AWRMajor HDA Components Jumper Location/Configuration Subsystem ConfigurationCylinder Limitation Dual Drive SupportDrive Configuration Product SpecificationsPerformance Specifications Models and CapacitiesPhysical Dimensions Power Mode Definitions Power Requirements AverageEPA Energy Star Compliance Environmental LimitsShock and Vibration Reliability SpecificationsCanadian Emissions Statement Safety Regulatory ComplianceRadiated Electromagnetic Field Emissions EMC Compliance Hard Drive Handling Precautions Handling and InstallationPre-formatted Drive Important NoticeMulti-pack Shipping Container Unpacking and InspectionRepacking Physical InstallationRecommended Mounting Configuration Important Please Read Before You BeginHard Drive Identification General RequirementsMounting Drive in System Systems Using Cable SelectAttaching System Cables Attaching Interface and Power CablesSetting the Bios Cmos System SetupHard Drive Preparation How to Obtain MaxBlast Software System Hangs During Boot