Moen T555, T473 installation instructions Installation Instructions, Measurements, MT662C, Clip

Models: L2600 MODEL SERIES T471 TL473 L2700 TL471 TL470

1 4
Download 4 pages 15.44 Kb
Page 1
Image 1
MT662C

MODELS 2600, 2700, 5401, 62600, 62700, 72615, 72700 and MODEL SERIES T471,

MT662C

T473, T555, T666, T777, T888, TL470, TL471, TL473, L2600, L2700

 

®

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE

LEFT WITH HOMEOWNER

TUB AND SHOWER VALVES

Available with three or four port castings, with and without stops.

Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.

If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.

Measurements

These are shown in the drawings. The depth measurement is critical.

Use the front face of the plaster ground as a reference point for the fin- ished wall position, including tile (2-1/16" [52mm]). The center line of the supply and discharge piping should be a maximum of 2-3/16" (56mm) and a minimum of 1-7/16" (37mm) behind the finished wall surface.

IMPORTANT: SEE FLUSHING INSTRUCTIONS PAGE 2

A

B

 

TUB/SHOWER

 

FLANGE

FINISHED WALL

 

COMBINATION

 

 

LINE

 

 

 

SHOWERHEAD

 

 

 

 

 

 

SHOWER

 

 

 

 

 

ARM

2-1/16"

 

HANDLE

HANDLE

 

 

 

 

 

(52mm)

 

COVER

KNOB

WASHER

PLASTER

 

6' 6"

 

 

 

GROUND

1-1/4"

 

 

 

 

(1981mm)

 

 

 

ESCUTCHEON

(32mm)

 

 

 

 

 

 

HANDLE

HANDLE

SUPPLY

SCREW

LEVER

TUB FILLER OR SHOWER

2-1/16" (52mm)

SUPPLY

INSTALLATION INSTRUCTIONS 15/16"

C

 

STOP TUBE

 

HANDLE LEVER HANDLE SCREW HEXAGONAL

 

 

WRENCH

 

 

WASHER

 

SET SCREW

STOP TUBE

 

HANDLE ADAPTER &

FLOOR

BRAKE ASSEMBLY

 

32"

(813mm)

CAUTION

USE 1/2"

IRON PIPE

SIZE

MINIMUM

OR 1/2"

TUBING.

(24mm)

45"

(1143mm)

48"

(1219mm)

Always turn water off before installing or disassembling the valve. Open

CAUTION: valve handle to relieve water pressure and to insure that complete water shut-off has been accomplished.

Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place. The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the premises could result.

CLIP

EAR

Page 1
Image 1
Moen T555, T473 installation instructions Installation Instructions, Measurements, MT662C, Clip, Tub And Shower Valves