Eicon Networks DM/V600A-2E1-PCI After Installing the Hardware, Warranty and Return Information

Page 2

5. Using the slot’s board guides, insert the board’s edge

Installing the CT Bus Cable

connector into the bus slot. Press firmly until the

Colored

CT Bus

Dialogic also provides direct support via Dialogic® Pro™

board is securely seated in the slot.

Stripe

Cable

Services agreements. For more details of direct support

Installing a PCI Board

 

Remove

PCI

Cover

Board

Plate

 

Computer

 

Chassis

 

 

32-Bit

 

PCI Slot

 

16-Bit

 

ISA Slot

6.Replace and tighten the slot’s retaining screw to secure the board firmly in the chassis (if applicable).

7.Connect external digital telephone cables to the RJ-48C jacks on the board bracket. The topmost RJ-48C jack is for trunk 1 and the second RJ-48C jack is for trunk 2.

Pinouts for the RJ–48C

Network Interface

Jacks on Bracket

Cable Connector

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

1 RCV_RING

Pin 1

2RCV_TIP

3CHASSIS GROUND

4XMIT_RING

5XMIT_TIP

6CHASSIS GROUND

7CHASSIS GROUND

8CHASSIS GROUND

8.Repeat steps 3-7 for each additional board you are installing.

9.Use the CT Bus cable to connect the board(s) you are installing to other boards in the system. To preserve the electrical integrity of the CT Bus, use a CT Bus cable with the appropriate number of connectors (“drops”). It is recommended that no more than two connectors at either end of the cable be left unused.

10.Your system may include both CT Bus and SCbus boards. To connect both board types, you must install a CT Bus/SCbus Adapter on one of the CT Bus boards in a system. See the CT Bus/SCbus Adapter Quick Install Card for installation details about the Adapter and the bus cables

(Pin 1)

Note:

Your CT Bus cable may have a different number of connectors (drops).

11.Install CT Bus Termination Jumpers only on boards located at each end of the CT Bus cable. See the “Physical Description” section for jumper details.

12.Replace the computer’s cover when finished and reconnect the power cords.

13.Turn the computer’s power ON.

CAUTION: If your BIOS is set to use Plug and Play technology and there are ISA boards in your system, an IRQ conflict can be created if a PCI board is assigned the same IRQ as an ISA board. This could cause the machine to stop responding. You can prevent this by entering the BIOS and reserving the appropriate IRQs (those used by your ISA boards) for ISA use only.

After Installing the Hardware

After installing the hardware, run the Dialogic® Configuration Manager (DCM) as described in the installation instructions included with the Dialogic® System Software to configure your system.

For technical specifications and product information go to: http://www.dialogic.com/products.htm.

Warranty and Return Information

Warranty Period

For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/warranties/.

Contacting Technical Support

Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel. Outside the United States please refer to http://www.dialogic.com/support/contact .

from Dialogic please refer to: http://www.dialogic.com/support/DialogicPro.

Returning a Product

To return a board for warranty or any other returns, please refer to the following: http://www.dialogic.com/support/hwfaults .

Sales Assistance

If you have a sales question, please contact your

local Sales Representative or the Regional Sales Office for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm. To purchase Dialogic® products, please refer to the following website to locate the appropriate supplier:

http://www.dialogic.com/purchase.htm.

All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.

Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.

It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.

Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.

Image 2
Contents Before You Begin Configuring the HardwareInstalling the Hardware Installing the CT Bus Cable After Installing the HardwareWarranty and Return Information Installing a PCI Board

64-0074-02, DM/V600A-2E1-PCI specifications

Eicon Networks' 64-0074-02, also identified as the DM/V600A-2E1-PCI, represents a significant advancement in data communication technology, particularly designed for high-performance networking solutions. This versatile card provides robust functionality that caters to various network demands, making it an essential component in enterprise environments.

One of the standout features of the DM/V600A-2E1-PCI is its dual E1 interface, enabling seamless connection to digital telecommunications networks. With the capability to manage up to 30 voice channels per E1 line, this card is ideal for businesses that require efficient voice and data integration. The card's ability to support both voice and data traffic simultaneously ensures that organizations can optimize their communication infrastructure without compromising performance.

Equipped with a PCI interface, the DM/V600A-2E1-PCI provides easy installation within a range of server configurations. The PCI standard ensures compatibility with a broad spectrum of systems, facilitating straightforward upgrades and integration into existing infrastructure. This compatibility is further enhanced by the card's ability to handle diverse protocols, allowing for flexible deployment in various network settings.

Eicon Networks has incorporated advanced technologies into the DM/V600A-2E1-PCI to ensure high reliability and low latency in data transmission. The card supports error correction mechanisms and includes features such as echo cancellation, enhancing the quality of voice communications. This capability is particularly important for businesses that rely on clear, uninterrupted communication.

The DM/V600A-2E1-PCI is designed with scalability in mind. Its architecture allows for easy expansion, enabling organizations to increase their capacity as needed without overhauling their existing systems. This future-proofing aspect is crucial in today’s rapidly evolving technology landscape, where businesses need to adapt quickly to changing demands.

Additionally, the card comes equipped with comprehensive management and monitoring tools. These features provide network administrators with the ability to track performance metrics, diagnose issues, and facilitate proactive management of network resources. This level of oversight contributes to enhanced service reliability and user satisfaction.

In summary, Eicon Networks' 64-0074-02, DM/V600A-2E1-PCI is a feature-rich, robust solution tailored for modern network communication needs. Its dual E1 capabilities, PCI compatibility, advanced technologies, and management features position it as an invaluable asset for organizations looking to enhance their network infrastructure and optimize their communication workflows.