ENGLISH
Counting Scale 9222
Displaying the sum total
•Press .
Deleting the sum total in the memory
•Press C .
■Saving PLU (Product Look Up)
PLUs are used to store information on parts that are used regularly, so that the data can be retrieved quickly from the memory. The PLU number contains data on the tare weight, name and unit weight. Depending on the model, the scales can store up to 1000 PLUs.
Saving under the PLU shortcut keys | 01 | 12 | |||
13 | 24 | ||||
• Calculate the unit weight |
| ||||
PLU | as described in "Counting". |
| |||
|
| ||||
• | Press | PLU | . |
|
|
|
|
| |||
• Press the required PLU shortcut key, | |||||
| e.g. | 01 |
|
|
|
| 13 . |
|
|
| |
| For the lower value press the PLU | ||||
| shortcut key again. |
|
| ||
• | Press | PLU | . |
|
|
|
|
| |||
PLU is programmed. |
|
|
|
| |
Saving under the numerical keys |
| ||||
• Calculate the unit weight |
| ||||
PLU | as described in "Counting". |
| |||
|
| ||||
• | Press | PLU | . |
|
|
|
|
|
•Enter the required numerical value for the PLU number.
•Press PLU .
PLU is programmed.
■Selecting PLUs
Selecting PLUs stored under
the PLU shortcut keys | 01 | 12 |
13 | 24 |
•Press the required PLU shortcut key. For the lower limit press the key again.
PLU is activated.
Selecting the PLUs stored under
• Press | PLU | until you hear the audible signal. |
|
|
•Enter the PLU number.
•Press PLU .
PLU is activated.
Note: The PLU numbers of the shortcut keys and the numerical keys are shown identically on the right. Note the displayed unit weight (e.g. a different value may be stored under
Editing PLUs
•Call up the PLU to be changed.
• Press | PLU | . The unit weight will flash. |
|
|
•Enter a new unit weight.
•Press PLU .
The new PLU is stored.
■Programming the PLUs
with Tare Weight
•Place the tare weight on the scales.
•Press .
Continue as described in "Saving PLU (Product Look Up)".
10