Furman Sound manual PS-PRO Specifications

Page 12

PS-PRO SPECIFICATIONS

Current rating:

20 Amps (2400 Watts at 120 VAC)

Input Voltage:

85 to 264 VAC without damage

Mains Wiring analyzer: Detects one normal mode and five fault modes

Delay Intervals:

Total elapsed ON or OFF delay time adjustable

 

from 1-60 seconds, with a single trimpot:

ON sequence:

Delay 1 outlets go on immediately with switch.

 

Delays between outlets 1 and 2, and 2 and 3,

 

adjustable from 1-30 seconds each

OFF sequence:

Delay 3 outlets go off immediately with switch.

 

Delays between outlets 3 and 2, and 2 and 1,

 

same as ON delays

Remote Switch:

Screw terminals, 2 for switch, 2 additional for

 

optional LED (22 ga. minimum)

Spike Protection Modes:Line to neutral, neutral to ground, line to ground

Clamping Voltage, all modes:

200V peak

Response time:

1 nanosecond

Maximum surge current:

11,000 amps (8 x 20mS pulse)

Maximum spike energy: 550 joules total

Noise attenuation:

Differential mode: Greater than 40 dB; Common

 

mode: greater than 60 dB; both 1 to 200 MHz

Dimensions:

1.75” H x 19”W x 10” D.

Weight:

6 lbs (2.7 kg).

Construction:

Steel chassis, zinc chromate plating; .125”

brushed and black anodized aluminum front panel;

glass epoxy printed circuit boards.

Power Consumption:

11 watts

Safety Agency Approvals:

UL, NRTL-C, C-UL, CE listed.

Optional:

220/240V Versions (units with “E” suffix only) are

 

intended for use in countries with nominal 220 to

240 volt AC mains. Their rear panel outlets use internationally accepted IEC-320 connectors.

Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 USA

Phone: 707-763-1010 Fax: 707-763-1310 Web: www.furmansound.com E-mail: info@furmansound.com

0004-090202-D

Image 12
Contents PS PRO Power CONDITIONER/SEQUENCER Features Installation DescriptionPower Sequencing Features RecommendationsPower Conditioning Features Mains Wiring Fault AnalyzerSequencing Local ControlRemote Control Maintained ModeFront Panel Rear Panel Momentary Mode Maint OFFFlashing Delay 1 Indicator Effects of LightningMultiple Units Status TerminalThree Year Limited Warranty SER Vice PS-PRO Specifications