Furman Sound PS-PRO manual Momentary Mode, Maint OFF

Page 8

PS - PRO - POWER CONDITIONER/SEQUENCER

The connection of the REM terminal to the +12V terminal initiates an OFF sequence. Disconnecting initiates an ON sequence. If the cable run is long, it is recommended that the REM wire be tied to the PS-PRO’s GND terminal during ON operation rather than leaving it floating. This will require the use of a third conductor and a double-throw switch.

REM to +12V = ON (jumper plug installed on JMP3,

MAINT OFF)

The connection of the REM terminal to the +12V terminal initiates an ON sequence. Disconnecting initiates an OFF sequence. If the cable run is long, it is recommended that the REM wire be tied to the PS-PRO’s GND terminal during OFF operation rather than leaving it floating.

REM to GND = ON (jumper plugs installed on JMP1 and JMP4)

The connection of the REM terminal to the GND terminal initiates an ON sequence. Disconnecting initiates an OFF sequence.

NOTE: In Maintained Mode DO NOT USE the“START ON-OFF SEQUENCE” switch on the front panel. If you do you may activate an unintended sequence. If a Furman RS-1 is the controlling switch contact Furman’s Tech Support department for the proper wiring diagrams.

REM to +12V = OFF

7

MOMENTARY MODE

In Momentary Mode (jumper plug installed on JMP2)

The PS-PRO has “memory” — it only needs a

momentary signal from the remote switch to change its state from ON to OFF. When first plugged in (or after power is lost and reapplied for any reason) the stored state is OFF, and the DELAY 1 LED will flash. The unit will stay off until sequenced ON by a momentary connection of the REM IN terminal to +12V (the key switch must be in the REM position). The sequence starts on the rising edge of the signal.

The front panel START ON-OFF SEQUENCE switch is in parallel with, and functionally equivalent to, one or more remote momentary switches that may be connected to the terminal strip in the rear.

The “memory” is independent of the key switch. This means that even if the unit is sequenced off by turning the key lock switch to OFF, when the key lock switch is turned back to REM, the unit will sequence back on — it will not be necessary to push the START ON-OFF SEQUENCE button again. The unit“remembers”its state until the incoming power is lost, in which case it would default back to OFF.

MOMENTARY MODE

The front-panel key lock switch is not the primary means of control in the momentary mode and should normally be left in REM. It may be a useful secondary means of control in the rare case of

having several PS-PRO’s in parallel if there is some reason to shut down one unit without affecting the others. Because it is a maintained-contact switch, the RS-1 is not an appropriate remote switch for the

Image 8
Contents PS PRO Power CONDITIONER/SEQUENCER Features Installation DescriptionPower Sequencing Features RecommendationsPower Conditioning Features Mains Wiring Fault AnalyzerSequencing Local ControlRemote Control Maintained ModeFront Panel Rear Panel Momentary Mode Maint OFFFlashing Delay 1 Indicator Effects of LightningMultiple Units Status TerminalThree Year Limited Warranty SER Vice PS-PRO Specifications