PS - PRO - POWER CONDITIONER/SEQUENCER
The connection of the REM terminal to the +12V terminal initiates an OFF sequence. Disconnecting initiates an ON sequence. If the cable run is long, it is recommended that the REM wire be tied to the
REM to +12V = ON (jumper plug installed on JMP3,
MAINT OFF)
The connection of the REM terminal to the +12V terminal initiates an ON sequence. Disconnecting initiates an OFF sequence. If the cable run is long, it is recommended that the REM wire be tied to the
REM to GND = ON (jumper plugs installed on JMP1 and JMP4)
The connection of the REM terminal to the GND terminal initiates an ON sequence. Disconnecting initiates an OFF sequence.
NOTE: In Maintained Mode DO NOT USE the“START
REM to +12V = OFF
7
MOMENTARY MODE
In Momentary Mode (jumper plug installed on JMP2)
The
momentary signal from the remote switch to change its state from ON to OFF. When first plugged in (or after power is lost and reapplied for any reason) the stored state is OFF, and the DELAY 1 LED will flash. The unit will stay off until sequenced ON by a momentary connection of the REM IN terminal to +12V (the key switch must be in the REM position). The sequence starts on the rising edge of the signal.
The front panel START
The “memory” is independent of the key switch. This means that even if the unit is sequenced off by turning the key lock switch to OFF, when the key lock switch is turned back to REM, the unit will sequence back on — it will not be necessary to push the START
MOMENTARY MODE
The
having several