SERIES II 16 AMP POWER CONDITIONERS
2.If all of the LED’s on the voltmeter flash, the input voltage is marginally high. The
255 – 260 V).
3.If none of the LED’s on the voltmeter are lit, and the Extreme Voltages LED indicator is illuminated, then the
Digital Voltmeter:
(PL-PRO DE II, PL-PRO PDE II, PM-PRO E II
and PM-PRO PE II)
Furman’s
Digital Current Meter:
NOTE: Your Series II Power Conditioner does not compensate for high or low line voltage. If you frequently move your rack to different locations, derive power from generators, use long extension cords, travel internationally, or are in an area prone to brownouts, you may benefit from the use of one of Furman’s AC Line Voltage Regulators.
On/Off Circuit Breaker:
This 16 amp capacity magnetic circuit breaker switch is specifically designed to stand up to the enormous high inrush current demands of many power amplifiers. Additionally, the switch is shielded from accidental power disconnection with a hinged cover.
Extreme Voltage Shutdown Indicator: This LED is normally off. It monitors a hazard common in the entertainment industry: wiring faults – for example, accidental connection to 380 VAC where 240VAC is expected. The Series II SMP+ circuit senses voltages that are so high that operation would be impossible and shuts the power down before damage can occur. Upon initially applying power to these units, the Extreme Voltage indicator LED will light if the input voltage is above the extreme voltage cutoff, and power will not be applied to the unit’s outlets. If the unit has been operating with an acceptable input voltage and subsequently that voltage exceeds 280V, it will shut off power to the outlet and the Extreme Voltage LED will light.
7