Exergen DT 1001-LT, DT 1001-RS, DT 1001-LN manual Instructions for Applying Disposable Covers

Page 5

Instructions for Applying Disposable Covers

Model 1001 LT Only

Start with film perforation at edge of box tongue. Pinch bottom of white ring, push ring over peg.

1

Stop at Perforation

Release pinch, gently pull box away from probe to release film from box. Pinch just below next ring, before per- foration.

2

Rotate instrument into film until probe faces opposite direction, push ring on peg.

3

Release pinch. Pull box slightly away until next white ring is visible. Pinch ring, break film apart at perforation.

4

Contact vs. Non-Contact Measurements

In using any infrared temperature device, closer is always better, as the field of view increases proportionately to the distance from the surface. Accordingly, for maximum accuracy the probe must contact the sur- face at the point of interest. It does not need to be tightly pressed to the surface; a gentle touch is all that is required.

When contact with the surface is not an option, position the probe within 1/2 inch from the surface of interest. If using a non-contact protocol, the relative temperature indication of the instrument will be accurate.

3

Image 5
Contents Exergen IV. References Product Specifications DT-1001 RS InstrumentsOptional Disposable Covers Instruments FeatureUse With Disposable Cover Use Without Disposable CoverContact vs. Non-Contact Measurements Instructions for Applying Disposable CoversOperation and Controls Using the DermaTempTo Lock Reading To RestartNon-Contact Scanning Operating Modes Model SpecificFahrenheit or Celsius Conversion Changing the BatteryCleaning Care and Maintenance HandlingSelf Diagnostics Continuous Single Beeping CalibrationQuestions Customer Service If repair is requiredContinuous Double Beeping II. Body Surface Temperature History and Introduction Body Surface Temperature Infrared Thermometry Page Method Impedimenta DermaTemp Infrared Thermographic ScannerSolving the Problems Ambient Effect on Body Surface TemperatureBlackbody EmissivityPage Alice’s Quest for Emissivity Is it possible to see a mirror? Detection by Exception Correcting for Emissivity AutomaticallyPage Regional Blocks III. Clinical ApplicationsJoint Inflammation Epidural Catheter Positioning in Labor and DeliveryReconstructive Surgery Digital Perfusion AssessmentDiabetic Foot Screening Lower Back PainCerebrovascular Disorders Peripheral Nerve InjuryWound Management Neonatal Skin TemperatureThermal Assessment of Skin Diseases and Allergy Skin Temperature in Prognosis of the Critically IllRaynaud’s Syndrome Temperature Gradients in Detection of ShockOther Areas or Applications of Interest IV. References Page Astm Product SpecificationsExergen

DT 1001-LN, DT 1001-RS, DT 1001, DT 1001-LT specifications

The Exergen DT 1001 series, consisting of the DT 1001-LN, DT 1001, DT 1001-RS, and DT 1001-LT, represents a cutting-edge advancement in non-invasive infrared thermometry technology. These models are designed for accurate and reliable temperature measurement across various settings, making them invaluable tools for healthcare professionals, educators, and individuals monitoring their own health.

A standout feature of the Exergen DT 1001 series is its precision in measuring core body temperature. Utilizing patented infrared technology, these devices detect the thermal radiation emitted by the temporal artery, thus providing an accurate representation of internal body temperature. This non-invasive method is not only safe but also quick, as it can yield results within seconds, making it ideal for both clinical environments and home use.

The DT 1001 series emphasizes ease of use. Equipped with a simple one-button operation, even individuals without technical training can operate the device effectively. The easy-to-read digital display provides clear temperature readings, which can often be coupled with visual and auditory alerts for fever detection, enhancing user experience.

Further enhancing user convenience is the memory function of the DT 1001 series. These models can store multiple readings, allowing users to track temperature trends over time. This feature is particularly useful in monitoring patients with fevers or chronic health issues where regular temperature checks are necessary.

The DT 1001-LN and DT 1001-LT are distinguished by their lightweight and portable design, making them suitable for on-the-go temperature checks. Conversely, the DT 1001-RS is optimized for clinical settings, featuring enhanced durability and robust performance under frequent usage.

Each model has been rigorously validated to meet clinical standards, ensuring that healthcare practitioners can rely on their accuracy. With their advanced technology, user-friendly design, and versatility, the Exergen DT 1001 series stands out as a leading choice in the realm of non-contact thermometers, promoting effective health monitoring for a wide range of users. Their continued popularity highlights a significant trend in modern healthcare towards efficient, precise, and non-invasive diagnostic tools.