ETA’s line of Conditioned Power Distribution units are designed to reduce damage to sensitive electronic equipment
from sudden voltage spikes, damaging power surges, and EMI/RFI noise, which is inherent in utility power lines. The PD11SP is a sequential four step/stage power up/down conditioned power distribution unit. It is designed to
protect electronic equipment that requires a
PD11SP units are shipped with the ability to be linked or daisy chained. All linked units function as slaves; however, slaves can be set to specific time delays. Any number of units can be linked together with a distance of up to 1000 feet between each location (see Fig. 4).
1 thru 4 steps/stages in sequential power up/ | Breaker protected and unswitched |
down 1, 5, 10, 30 second | 15 amp outlet |
|
|
|
|
|
| 20 amp total unit breaker | |
|
|
|
|
| 15 amp front panel outlet breaker | ||
Sequential | Protection "On" |
| |||||
Power switch | |||||||
| On / Off | Indicators | On / Off | ||||
|
|
|
|
|
|
| Input RCA phono jack |
|
|
|
|
|
|
| Output RCA phono jack |
|
|
|
|
|
|
| 3 pin terminal block for remote |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| sequential operation of unit |
|
|
|
|
| Output screw terminal | ||
Stage 1 | Stage 2 | Stage 3 | Stage 4 | Input screw terminal |
PD11SP Features:
•Microprocessor monitored sequential power distribution system
•Four power up/down steps or stages of distributed and conditioned power
•Four
•Optional manual settings for up to 240 seconds between intervals
•One dual 20 amp
•Full 20 amps, 2400 watts capacity per unit
•
•Protected "always on" 15 amp AC power outlet on the front panel
•Total unit 20 amp and 15 amp outlet circuit breakers located on front panel
•
•
•Ground and AC line fault check
•One rack space high
•One year limited warranty
Other Features:
•Remote control operation
•Standard rear panel RCA connectors and 2 screw terminals
Specifications:
Dimensions | 19" L x 10" D x 1 3/4" H |
Weight | 10 lbs. |
Quality | Black powder coated chassis, black anodized aluminum front panel |
Electrical | 120V, 50/60 Hz, single phase |
Max. amps | 20/unit |
Max. watts | 2400/unit |
Max. front outlet | 15 amps |
Spike/surge protection | Line to neutral, neutral to ground, line to ground |
Clamping level | 200V peak |
Response time | 1 nanosecond |
Max. surge voltage | 6000V |
Max. surge current | 26,000 amps |
Max. spike energy | 630 joules total |
Noise attenuation | Transverse greater than 20 dB, 1.5 kHz to 200 MHz |
Certification | ETL listed |