Dynacord DPP 4004, DPP 4012 owner manual Specifications, DPP4004 DPP4012

Page 9

DYNACORD

PROMATRIX SYSTEM

SPECIFICATIONS

 

 

 

DPP4004

 

DPP4012

Mains power supply

 

 

 

Operational voltage

230 VAC ±10 %

 

230 VAC ±10 %

internally selectable through bridging

115 VAC ±10 %

 

115 VAC ±10 %

Mains frequency range

50 … 60 Hz

 

50 … 60 Hz

Power consumption in idling mode

œœ20 VA

œœ

20 VA

Power consumption at nominal load

œœ120 VA

 

œœ360 VA

Battery power supply

 

 

 

Battery voltage

24 V –10 %/+30%

24 V –10 %/+30 %

Current consumption in idling mode

œœ0.17 A

 

œœ0.17 A

Current consumption at nominal load

œ4.1 A

 

œ12.1 A

Current power handling capacity

 

 

 

with MAINS REMOTE ON

1 A

 

1 A

Current power handling capacity

 

 

 

with BATTERY REMOTE ON

1 A

 

1 A

Current power handling capacity

 

 

 

with DELAY OUT

0.1 A

 

0.1 A

Input current ON/OFF (TOGGLE)

> 2.2 mA = ACTIVE

< 1mA = inactive

Input current ON/OFF (MODULES)

> 2.2 mA = ON

 

< 1mA = OFF

Output data

 

 

 

Nominal output voltage

24 V

 

24 V

Nominal output current with forced ventilation

4 A

 

12 A

Residual voltage standing wave d mV pp

< 100mV pp

 

< 100mV pp

Mains stabilization

±1 %

 

±1 %

Safety

EN 60065

 

EN 60065

Radio interference

EN 55022 (B)

 

EN 55022 (B)

 

EN 50082 - 1

 

EN 50082 - 1

 

EN 61000 4-2....4-6

EN 61000 4-2....4-6

 

ENV 50204

 

ENV 50204

 

 

 

EN 61000-3-2

 

 

 

EN 61000-3-3

Environmental temperature

+5 °C … +40 °C

 

+5 °C … +40 °C

Dimensions (W x H x D)

19" x 2 HU = 483 x 88 x 330 mm

Depth incl. connections

400 mm

 

400 mm

Weight

7 kg

 

7 kg

19

Image 9
Contents Performance Features 24V Power Supply Rack UnitContents For US and Canada only Important Safety InstructionsDynacord Utilization First OperationFunctions of the DPP4004/4012 Dynacord DPP Following only applies to the DPP4012ON/OFF Toggle Input Remote Control ConnectorDPP4004 DPP4012 Specifications