Cable Routing Procedures for Dell™ PowerEdge™ R415 Systems

Section 2: Cabling a Dell™ PowerEdge™ R415 System Without a CMA

NOTE: The CMA on Dell™ PowerEdge™ R415 systems is optional. Without the CMA installed, the system must be powered down and all cables disconnected before it can be removed from the rack.

2.1 Routing the Cables

1.Connect all applicable cables to the rear of the system and verify that all connections are secure.

2.Using the hook and loop straps supplied with the rail kit, bundle the cables and secure them to either the left or right CMA attachment brackets as described in the Rack Installation Instructions. See Figure 8 for an example of data cables secured to the left CMA bracket and power cables secured to the right CMA bracket.

3.It is recommended that the cables be secured to the outer brackets, but cables may be secured to the inner brackets as well if desired.

Figure 8: Cable Routing Without a CMA

2.2 Removing the CMA Brackets for Shallow Racks

If you are installing the system into a shallow rack (less than 1 meter deep) and you will not be installing a CMA, the outer CMA brackets may be removed if necessary in order to allow the rails to fit properly into the rack. Remove the brackets by using a #2 Phillips screwdriver to remove the screws used to attach them to the rails as shown in Figure 9.

Page 7

Image 9
Contents Cable Routing Procedures for Dell PowerEdge R415 Systems Cable Routing Procedures for Dell PowerEdge R415 Systems Contents Introduction Connecting the CMA Cables to the SystemInstalling the Inner CMA Attachment Bracket Routing the Power Cables Through the Strain ReliefsRouting the Cables Through the CMA Routing the Cables Through the CMA Left-Side Mounting InstructionsAttaching the KVM Dongle to the CMA Basket Right-Side Mounting Instructions Left-Side Mounted CMA Installation PreferredCabling a Dell PowerEdge R415 System Without a CMA Routing the CablesRemoving the CMA Brackets for Shallow Racks CMA Replacing a Power Supply on a PowerEdge R415 System With aDisconnecting the Inner CMA Attachment Bracket Cabling a PowerEdge R415 System Installed in Static RailsCabling a System Installed in Static Rails