Dell MD3620F, MD3600f owner manual Configuring Snmp Alerts

Page 81

9For the selected e-mail address, in Frequency, select:

Every event—Sends an alert e-mail whenever an event occurs. This is the default option.

Every x hours—Sends an alert e-mail after the specified time interval if an event occurred during that time interval. You can select this option only if you have selected either Event + Profile or Event + Support in the Information To Send drop down list.

10Click OK.

An alert icon appears next to each node in the Tree view where an alert is set.

To ensure that the e-mail is sent successfully:

You must provide a SMTP mail server name and an e-mail sender address for the e-mail addresses to work.

The e-mail addresses that you had previously configured appear in the Configured e-mail addresses area.

You must use fully qualified e-mail addresses, for example, name@mycompany.com.

You can configure multiple e-mail addresses before you click OK.

Configuring SNMP Alerts

To add a management console to the list of addresses configured to receive SNMP alerts:

1Open the Configure Alerts dialog by performing one of these actions:

In the Tree view or the Table view on the Devices tab in the EMW, select a node, and select EditConfigure Alerts. Go to step 3.

In the Setup tab in the EMW, select Configure Alerts. Go to step 2.

2Select one of the following radio buttons to specify an alert level:

All storage arrays—Select this option to send an alert notification about events on all storage arrays.

An individual storage array—Select this option to send an alert notification about events that occur in only a specified storage array.

Configuration: About Your Storage Array

81

Image 81
Contents Dell PowerVault MD3600f and MD3620f Storage Arrays Page Contents Planning MD3600f Series Storage Array Terms and Concepts Cache Functions and FeaturesVirtual Disk Operations Limit Configuring Alert Notifications Configuration AboutMoving a Host to a Different Host Group Enabling or Disabling the Event MonitorStarting or Stopping the Host Context Agent Managing Host Port IdentifiersHost-to-Virtual Disk Mapping Configuring Hot Spare Physical Disks133 130134 135153 148Snapshot Repository Capacity 154 157Failed RAID Controller Module 167 167168 169Using Remote Replication Viewing the Properties Pane Viewing Logical Elements 211 Using DM Multipathing Devices 212219 221235 Power Supply/Cooling Fan Module 237239 242Self-Monitoring Analysis and Reporting 256 Media Errors and Unreadable Sectors 257Viewing the Firmware Inventory 259 261275 Recovering From an Unresponsive 276279 281Troubleshooting Expansion 294 Enclosure Management Modules Troubleshooting PowerTroubleshooting a Damaged Array 299 292About This Document IntroductionDell PowerVault Modular Disk Storage Manager Dell PowerVault MD3600f Series Storage ArrayOther Information You May Need Introduction Overview Planning About Your Storage ArrayFront-Panel Features and Indicators Hardware FeaturesPlanning About Your Storage Array Item Indicator, Button, or Icon Description Connector Back Panel Features and Indicators Hard Drive Indicators Hard-Drive Indicator PatternsDrive-Status Indicator Pattern Condition Power Supply and Cooling Fan FeaturesPower Indicator Codes Item LED Type Icon Description Power Indicator CodesRAID Controller Modules Planning RAID Controller ModulesFunction RAID Controller Module Connectors and FeaturesComponent Function RAID Controller Module-Additional Features Battery Backup UnitHost Channel LED Link/Rate Indications System Password Reset Cache Functions and FeaturesStorage Array Thermal Shutdown Cache MirroringSFP Transceivers, Fiber Optic, and SAS Cables Write-Back CacheWrite-Through Cache Fiber Optic Cable Connection Interoperability of 2 Gbps, 4 Gbps, and 8 Gbps Devices Physical Disks, Virtual Disks, and Disk Groups Planning MD3600f Series Storage Array Terms and ConceptsPhysical Disk States Physical DisksVirtual Disks and Disk Groups Self-Monitoring Analysis and Reporting TechnologyRAID Controller Virtual Disk States Description Virtual Disk StatesRAID Level Usage RAID LevelsRAID Segment Size Virtual Disk OperationsVirtual Disk Initialization Foreground Initialization Background InitializationConsistency Check Media VerificationVirtual Disk Operations Limit Cycle TimeDisk Group Operations RAID Level MigrationSegment Size Migration Disk Group Expansion Virtual Disk Capacity ExpansionDisk Group Defragmentation Disk Group Operations LimitRAID Background Operations Priority Disk Migration Virtual Disk Migration and Disk RoamingPlanning MD3600f Series Storage Array Terms and Concepts Advanced Features Disk RoamingHost Server-to-Virtual Disk Mapping Snapshot Virtual Disks Host TypesVirtual Disk Copy Snapshot Repository Virtual DiskVirtual Disk Recovery Source Virtual DiskTarget Virtual Disk Using Snapshot and Disk Copy Together Multi-Path SoftwarePreferred and Alternate Controllers and Paths Virtual Disk Ownership Load BalancingMonitoring MD3600f Series System Performance Planning MD3600f Series Storage Array Terms and Concepts Performance Monitor Table Description Column Headings Planning MD3600f Series Storage Array Terms and Concepts User Interface Configuration OverviewEnterprise Management Window Array Management Window Inheriting the System SettingsConfiguration Overview Out-of-Band Management Out-of-Band and In-Band ManagementStorage Arrays Adding Storage ArraysIn-Band Management Automatic Discovery of Storage Arrays Manual Addition of a Storage ArraySelect Edit→ Add Storage Array Setting Up Your Storage Array Locating Storage Arrays AMW, select Storage Array→ Blink→ Storage ArrayStop All Indications Name/Rename Storage Arrays dialog appears Naming or Renaming Storage ArraysType the New password Setting a PasswordViewing Storage Array Connections Password GuidelinesRemoving Storage Arrays Adding/Editing a Comment to an Existing Storage ArraySelect Edit→ Comment Select Edit→ Remove→ Storage ArrayFailover Alert Display Enabling Premium FeaturesChanging the Cache Settings on the Storage Array Changing Expansion Enclosure ID NumberChange→ Enclosure ID Select Configure Alerts Configuring Alert NotificationsChanging the Enclosure Order in the Physical Pane AMW, select Storage Array→ Change→ Enclosure OrderConfiguring E-mail Alerts Configuration About Your Storage Array Configuring Snmp Alerts Configuration About Your Storage Array Battery Settings Setting the Storage Array RAID Controller Module Clocks Configuration Event Monitor Windows Enabling or Disabling the Event MonitorLinux Select Action→ PropertiesConfiguring Host Access Configuration About Your HostDefining a Host Using the Mappings TabSelect Mappings→ Define→ Host Removing Host Access Managing Host GroupsSelect Mappings→ Remove Select Mappings→ Define→ Host Group Creating a Host GroupAdding a Host to a Host Group Removing a Host From a Host GroupRemoving a Host Group Moving a Host to a Different Host GroupSelect Mappings→ Move Move Host Confirmation dialog appearsHost Topology Starting or Stopping the Host Context AgentLinux Data Path Protection WindowsClick Action→ Start Managing Host Port Identifiers Add Host Port Identifier dialog appears Configuration About Your Host Configuration About Your Host Creating Disk Groups and Virtual Disks Configuration Disk Groups and Virtual DisksCreating Disk Groups Introduction Create Disk Group window is displayed100 101 Creating Virtual Disks Locating a Disk Group103 Map later Using Mappings View Changing the Virtual Disk Modification Priority104 105 Changing the Virtual Disk Cache Settings106 107 Changing the Segment Size of a Virtual DiskSelect Virtual Disk→ Change→ Segment Size Changing the I/O Type108 Modification PriorityChoosing an Appropriate Physical Disk Type File system typical Database Multimedia Custom109 110 Physical Disk Security With Self Encrypting Disk111 112 Creating a Security Key113 Click Create Key114 Changing a Security KeySaving a Security Key Click Change Key115 116 Unlocking Secure Physical Disks Erasing Secure Physical Disks117 Configuring Hot Spare Physical Disks Select Physical disk→ Hot Spare Coverage118 Hot Spare Physical Disk Options window is displayed Click Unassign119 Global Hot Spares Hot Spares and RebuildHot Spare Operation 120Enclosure Loss Protection Hot Spare Drive Protection121 Criteria for Enclosure Loss Protection RAID Level 122123 Host-to-Virtual Disk Mapping Creating Host-to-Virtual Disk Mappings124 125 Modifying and Removing Host-to-Virtual Disk Mapping Mapping126 Changing Controller Ownership of the Virtual Disk Select Virtual Disk→ Change→ Ownership/Preferred Path127 128 Removing Host-to-Virtual Disk MappingSelect Disk Group→ Change→ Ownership/Preferred Path Changing the RAID Level of a Disk GroupSelect Disk Group→ Change→ RAID Level 129Restricted Mappings 130Mapping Restrictions Operating System Highest LUN 131 132 Select Disk Group→ Ownership/Preferred Path. or133 Changing the RAID Level of a Disk Group134 Storage PartitioningDisk Group and Virtual Disk Expansion Select Disk Group→ Add Free Capacity Physical Disks135 Using Free Capacity Virtual Disk Expansion136 Disk Group Migration Using Unconfigured CapacityExport Disk Group Non-Exportable ComponentsExporting a Disk Group Import Disk GroupImporting a Disk Group 138Storage Array Media Scan Non-Importable Components139 140 Changing Media Scan Settings141 Suspending the Media Scan142 143 Configuration Premium Feature- Snapshot Virtual Disks144 Creating a Snapshot Virtual Disk Using the Simple Path145 About the Simple Path146 147 Select Virtual Disk→ Snapshot→ Create. orCreating a Snapshot Virtual Disk Using the Advanced Path About the Advanced Path148 149 150 151 Creating the Snapshot Using the Advanced Path152 Specify Virtual Disk Parameters window is displayed153 Specifying Snapshot Virtual Disk Names154 Snapshot Repository Capacity155 Click Add Physical Disks Add Physical Disks window closes156 Re-creating Snapshot Virtual Disks Select Virtual Disk→ Snapshot→ Re-create157 158 Disabling a Snapshot Virtual Disk159 Preparing Host Servers to Re-create a Snapshot Virtual Disk160 Re-creating a Snapshot Virtual Disk161 Configuration Premium Feature- Virtual Disk Copy162 Creating a Virtual Disk Copy for an Mscs Shared Disk163 Virtual Disk Read/Write Permissions164 Virtual Disk Copy RestrictionsCreating a Virtual Disk Copy Before You Begin165 Create Copy Wizard Virtual Disk Copy and Modification OperationsFailed Virtual Disk Copy 166Failed RAID Controller Module Preferred RAID Controller Module OwnershipCopy Manager 167168 Copying the Virtual DiskSetting Copy Priority Storage Array Performance During Virtual Disk Copy169 Recopying a Virtual Disk Stopping a Virtual Disk CopySelect Change→ Copy Priority 170171 Preparing Host Servers to Recopy a Virtual DiskRecopying the Virtual Disk Select Copy→ Re-Copy172 173 Removing Copy Pairs174 175 176 177 Configuration Premium Feature- Remote ReplicationActivating Remote Replication Replication Repository Virtual Disks178 RAID Levels for Replication Repository Virtual Disks Primary and Secondary Virtual Disk Pairs179 Using Remote Replication With Other Features Storage Partitioning With Remote Replication180 Virtual Disk Copy With Remote Replication Snapshot Virtual Disk With Remote ReplicationVirtual Disk Expansion With Remote Replication 181Switch Cascading Required Switch Zoning ConfigurationsZoning Guidelines for Remote Replication 182Journaling File Systems and Remote Replication Setting Up and Managing Remote ReplicationPrerequisites 183184 Preview Activate Remote Replication wizard is displayed Completed Activate Remote Replication message is displayed185 186 Creating a Remote ReplicationSetting the Write Mode Selecting the Secondary Virtual Disk187 188 Setting Synchronization Priority and Synchronization Method189 Completing the Remote Replication190 RAID Controller Module Ownership/Preferred Path191 Viewing the Storage Array ProfileViewing Logical Elements of the Secondary Virtual Disk Viewing the Properties PaneSelect View Associated Logical Elements 192193 Write Mode and Consistency Group Membership IconStatus Changing Write Mode and Consistency Group MembershipVirtual Disk Status Icons 194195 Select Change→ Write ModeResynchronizing Virtual Disks Normally Synchronized Virtual Disks196 197 Changing Synchronization Priority and Method198 199 Unsynchronized Virtual DisksAutomatically Resynchronizing Virtual Disks Manually Resynchronizing Virtual Disks200 201 202 Suspending a Remote ReplicationResuming a Remote Replication About Resumed Remote Replications203 204 Select Test Replication Communication205 Deleting a Primary Virtual Disk206 Deleting a Secondary Virtual Disk207 Removing a Remote Replication From a Storage Array208 Deactivating the Remote Replication on the Storage Array209 Disabling the Remote Replication Premium Feature210 211 Configuration Device Mapper Multipath for LinuxUsing DM Multipathing Devices Prerequisites212 Device Mapper Configuration Steps Scan for Newly Added Virtual Disks213 214 Create a New fdisk Partition on a Multipath Device Node Add a New Partition to Device Mapper215 Mount a Device Mapper Partition Create a File System on a Device Mapper PartitionReady for Use 216Device Mapper Commands Descriptions Important Information About Special Partitions217 218 Limitations and Known IssuesTroubleshooting 219QuestionAnswer 220 221 Recommended ToolsFront Bezel Optional Installing the Front BezelRemoving the Front Bezel 222Hard Drives Safety Models AMT, E03J, and E04JRemoving a Drive Blank 223Installing a Drive Blank Removing a Hard Drive224 225 Removing and Installing a Hard Drive226 Installing a Hard Drive227 Removing a Hard Drive From a Hard-Drive Carrier228 RAID Controller Module Installing a Hard Drive Into a Drive CarrierRemoving a RAID Controller Module Blank 229230 Installing a RAID Controller Module Blank231 Removing a RAID Controller Module232 Installing a RAID Controller Module233 Opening the RAID Controller Module234 Closing the RAID Controller ModuleRAID Controller Module Backup Battery Unit Removing the RAID Controller Module Backup Battery Unit235 236 Installing the RAID Controller Module Backup Battery UnitPower Supply/Cooling Fan Module Removing a Power Supply/Cooling Fan Module237 238 Installing a Power Supply/Cooling Fan ModuleControl Panel Removing the Control Panel239 240 241 Installing the Control PanelBackplane Removing the Backplane242 243 17. Removing and Installing the Backplane-PowerVault MD3620f 16. Removing and Installing the Backplane-PowerVault MD3600f245 Installing the Backplane246 247 Downloading RAID Controller and Nvsram Packages248 Downloading Both RAID Controller and Nvsram FirmwareSelect Tools→ Upgrade RAID Controller Module Firmware Click Transfer249 250 Downloading Only Nvsram Firmware251 252 Click Nvsram in the Download area253 Downloading Physical Disk Firmware254 Download Physical Disk Introduction window appearsDownloading MD1200 Series Expansion Module EMM Firmware AMW, select Advanced→ Maintenance→ Download→ EMM FirmwareDownload Environmental EMM Firmware dialog appears 255256 Self-Monitoring Analysis and Reporting Technology Smart257 Media Errors and Unreadable Sectors258 259 Viewing the Firmware Inventory260 Virtual Disk Service Microsoft ServicesVolume Shadow-Copy Service 261262 Device Health Conditions Start-Up Routine263 Start-Up Routine Indications Look/listen for ActionOn the Setup tab, select Manage a Storage Array 264Status Icon Description Additional Status Icons Description 265266 Storage Array Support DataAutomatically Collect the Support Bundle Data Enter the Execution summary267 268 Collecting the Physical Disk Data269 Event LogRecovery Guru Storage Array Profile270 271 Viewing the Logical Associations Select View→ Associated Logical Elements. or272 Viewing the Physical Associations Finding Nodes273 274 Select Find all free capacity nodesClick Find Next Using Go ToSelect View→ Go To→ Snapshot Virtual Disk Select View→ Go To→ Snapshot Repository Virtual DiskSelect View→ Go To→ Source Virtual Disk Recovering From an Unresponsive Storage Array ConditionSelect View→ Go To→ Target Virtual Disk 276277 278 Locating a Physical Disk Locating an Expansion Enclosure279 Capturing the State Information Select Physical Disk→ Blink→ Expansion Enclosure280 281 SMrepassist UtilityRecovering From an Unidentified Storage Array Unidentified Devices282 283 284 285 Starting or Restarting the Host Context Agent Software286 287 288 Troubleshooting Loss of Communication Troubleshooting an SFP Transceiver289 290 Removing an SFP Module 291Troubleshooting External Connections Troubleshooting Power Supply/Cooling Fan Module292 293 Troubleshooting Array Cooling Problems294 Troubleshooting Expansion Enclosure Management Modules295 Troubleshooting RAID Controller Modules296 Troubleshooting Hard Drives297 Troubleshooting Array and Expansion Enclosure Connections298 Troubleshooting a Wet Storage Array299 Troubleshooting a Damaged ArrayConditions ECC ErrorsInvalid Storage Array 300Critical Conditions PCI ErrorsNoncritical Conditions 301302 Contacting Dell Visit support.dell.com303 304 305 Index306 307 308 309 310 311 312
Related manuals
Manual 15 pages 37.81 Kb Manual 318 pages 20.85 Kb Manual 38 pages 3.57 Kb Manual 268 pages 41.83 Kb Manual 90 pages 60.6 Kb

MD3620F, MD3600f specifications

Dell's MD3620F and MD3600F storage arrays are designed for businesses seeking dependable, high-performance storage solutions tailored to meet the demands of modern data management. These models offer a blend of scalability, efficiency, and advanced features, making them well-suited for a range of applications, from virtual environments to critical database operations.

One of the primary features of the MD3620F and MD3600F is their support for a hybrid storage architecture. This approach allows organizations to combine flash storage with traditional hard disk drives (HDDs) to optimize performance and cost. The MD3620F focuses heavily on all-flash configurations, delivering exceptional speed and lower latency, ideal for I/O-intensive workloads.

Scalability is another hallmark of these storage solutions. The MD3600F allows users to scale up to 120 drives, providing robust capacity to meet growing data needs. The MD3620F is engineered for environments where data availability and speed are paramount, with support for high IOPS (Input/Output Operations Per Second) and consistent performance under stress.

In terms of data management, both systems integrate with Dell’s proprietary software, which enhances operational efficiency through features like automated tiering. This technology optimizes data placement between different storage types based on access frequency, ensuring that hot data is readily available while reducing costs associated with less critical data.

Reliability is crucial for businesses that depend on their storage systems. The MD3620F and MD3600F come equipped with advanced data protection mechanisms, such as RAID support, which safeguards against data loss, and snapshot capabilities that provide point-in-time copies of data. Moreover, these solutions include hot-swappable components, ensuring minimal downtime for maintenance and repairs.

Connectivity is also a strong suit of these storage arrays. They support multiple connectivity options, including SAS and iSCSI, allowing for flexible integration into existing IT infrastructures. This adaptability enhances their appeal to a wide range of enterprise environments.

In summary, the Dell MD3620F and MD3600F stand out as robust storage solutions with a combination of hybrid and all-flash configurations, scalability, advanced data management tools, and enhanced reliability features. These characteristics make them ideal for organizations looking to enhance their data storage capabilities while maintaining high performance and efficiency.