Dell M620 owner manual Regulatory Model HHB Regulatory Type HHB003

Page 1

Dell PowerEdge M620 Systems Owner's Manual

Regulatory Model: HHB

Regulatory Type: HHB003

Image 1
Contents Regulatory Model HHB Regulatory Type HHB003 Dell Inc Contents Installing Blade Components Using System Diagnostics Troubleshooting Your SystemJumpers And Connectors Technical Specifications System Messages133 Using USB Diskette or USB DVD/CD Drives Front-Panel Features And IndicatorsOther Information You May Need Hard-Drive/SSD Indicator PatternsFor insertion or removal during this time Page Page Keystroke Description Choosing The System Boot ModeSystem Setup Options Entering System SetupResponding To Error Messages Using The System Setup Navigation KeysSystem Information Screen System Bios ScreenProcessor Settings Screen Memory Settings ScreenBoot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings ScreenSystem Security Screen Miscellaneous Settings System And Setup Password FeaturesUsing Your System Password To Secure Your System Assigning a System And/Or Setup PasswordOperating With a Setup Password Enabled Entering The Uefi Boot ManagerBoot Manager Screen Using The Boot Manager Navigation KeysUefi Boot Menu IDRAC Settings UtilityEntering The iDRAC Settings Utility Embedded System ManagementPage Recommended Tools Removing And Installing a BladeRemoving The Blade Removing or Installing the Blade Installing The BladeOpening The Blade Opening And Closing The BladeClosing The Blade Inside The BladeRemoving The Cooling Shroud Cooling ShroudSystem Memory Installing The Cooling ShroudDimm Type Operating Frequency in MT/s Maximum Dimm Rank ChannelMemory Socket Locations ProcessorProcessor Heat Number of DIMMs Configuration Type Sink General Memory Module Installation GuidelinesWatts Serviceability RAS Features Mode-Specific GuidelinesAdvanced ECC Lockstep Sample Memory ConfigurationsDIMMs Speed System Capacity Dimm Size Number Organization1R x8, 1333 MT/s Removing Memory Modules Installing Memory Modules Module Mezzanine Cards Mezzanine Card Installation GuidelinesRemoving a Mezzanine Card Installing and Removing a Mezzanine Card Installing a Mezzanine CardReplacing The SD Card Management Riser CardReplacing The Internal USB Key Internal USB KeyReplacing The SD vFlash Card SD vFlash CardRemoving The Network Daughter Card/LOM Riser Card Network Daughter Card/LOM Riser CardProcessors Installing The Network Daughter Card/LOM Riser CardRemoving a Processor Installing and Removing a Heat Sink Processor Shield Opening and Closing Lever Sequence Socket-release lever Pin-1 corner of processor Installing a Processor Hard Drives/SSDs Hard Drive/SSD Installation GuidelinesRemoving a Hard Drive/SSD Shutdown Procedure For Servicing a Hard Drive/SSD Installing a Hard Drive/SSDInstalling a Hard Drive/SSD In a Hard-Drive/SSD Carrier Configuring The Boot DriveRemoving a Hard Drive/SSD From a Hard-Drive/SSD Carrier Removing The Hard-Drive/SSD Backplane Hard-Drive/SSD BackplaneSystem Board Installing The Hard-Drive/SSD BackplaneRemoving The System Board Removing and Installing the System Board Installing The System BoardReplacing The Nvram Backup Battery Nvram Backup BatteryRemoving The PCIe Extender Card/Storage Controller Card Storage Controller CardInstalling The PCIe Extender Card/Storage Controller Card Page Troubleshooting Your System Troubleshooting USB Devices Troubleshooting Hard DrivesTroubleshooting An Internal SD Card Troubleshooting The Blade System Board Troubleshooting ProcessorsTroubleshooting The Nvram Backup Battery When To Use The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic Controls Running Embedded System Diagnostics From An External MediaMenu Description ResultsJumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsDisabling a Forgotten Password Page Memory ConnectorsDrives Mezzanine Cards BatteryVideo EnvironmentalOperating temperature range Page LCD Status Messages System Error MessagesViewing LCD Messages Removing LCD MessagesAMP0301 Message Error Code Message Information ActionAMP0302 Message Details Action AMP0303 MessageAMP0306 Message Details Action Error Code Message InformationAMP0307 Message AMP0308 Message Details ActionAMP0312 Message Details Action Details ActionAMP0313 Message AMP0314 Message Details ActionAMP0318 Message Details Action AMP0316 MessageAMP0319 Message Details Action AMP0320 Message Details ActionASR0000 ASR0001 ASR0002 ASR0003 ASR0008 Page Error Code Message Information ASR0106 BAT0014 Message Error Code Message Information BAT0012BAT0015 BAT0017 BAT0019 CBL0006 CPU0000 CPU0002 Message Action Error Code Message Information CPU0001CPU0003 Message Action CPU0004 Message ActionCPU number is throttled CPU0202 Action CPU0201 Action MessageCPU0203 Action Message CPU0204 ActionCPU0700 Message Error Code Message Information LCD MessageCPU0701 Message CPU0702 MessageCPU0704 Message CPU0703 MessageCPU0801 Message CPU0802 Message Details ActionCPU0804 Message Error Code Message Information CPU0803CPU0805 CPU0806 MessageHWC1015 Message HWC1010 MessageHWC2006 Message Hardware. An iDRAC or BMC firmware update is needed Error Code Message Information DetailsDegraded HWC2011 MessageGetting Help Link tuning failure detected on IO module number MEM0002 Message MEM0001 MessageMEM0003 Message MEM0005 MEM0007 MEM0009 MEM0010 Message MEM0004 MessageMEM0022 Message MEM0701 MessageMEM1001 Message MEM0702 MessageMEM1003 Message MEM1012 MessageMEM1206 Message LCD Message SBE log disabled on location. Re-seat memoryMEM1208 Message MEM8000 Message20h offset 04h Kernel panic or bug check eventPCI1304 Message PCI1302 MessagePCI1306 PCI1308 PCI1310 PCI1314 PCI1316 An I/O channel check error was detected. Power cycle system PCI1354 PCI1356 PCI1358 PCI1360 PCI1362 PCI2000 PCI1350 MessagePCI3000 PCI3002 PCI3004 PCI3006 PCI3008 PCI2002 MessageError Code Message Information PCI3010 PDR1016 PDR1024 PST0128 PST0129 PST0130 PST0131 Message Power System Bios detected a failure with the SIO PST0195 PST0196 PST0254 PST0256 PSU0001 Message Reduce system configuration to minimum memory configurationPSU0003 PSU0004 PSU0005 PSU0006 PSU0007 Message Error Code Message Information PSU0002PSU0031 PSU1201 PSU1202 PSU1203 PSU1204 Error Code Message Information PSU0008Consumption OperationsPWR1005 Message Redundancy. If a power supply fails the system may shutdownSystem configuration From a power shutdownPWR1008 Message RFM1003 RFM1005 RFM1006 RFM1008 RFM1014Error Code Message Information RFM1016 Operations RFM1205 RFM2001 RFM2002 RFM2004 RFM2006 SEC0000 MessageMeet system requirements CompromisedDocumentation TXT error at boot TXT error during PostComprised TXT operationAction Backup and clear log Message Logging is disabled DetailsSome management software do not report platform exceptions Overwritten and lostCall support SEL1204 SEL1209 SEL1211 SEL1300 SEL1302Invalid boot sector found -E option Action Upgrade the management software SWC4004 MessageFirmware TMP0103 TMP0104 TMP0106 TMP0107 TMP0108 TMP0109 Message Message InformationName temperature is less than the lower warning threshold Message System inlet temperature is outside of range Error Code Message Information TMP0119Details Ambient air temperature is too warm or cool Action Disk drive bay temperature is outside of range. Check FansAction Review system logs for power supply exceptions Safe modeIf the issue persists, see Getting Help VLT0101 MessageVLT0103 Message VLT0102 MessageVLT0104 Message VLT0200 MessageVLT0202 Message VLT0201 MessageVLT0203 Message VLT0204 MessageVLT0207 Message VLT0206 MessageVLT0208 Message VLT0210 Message VLT0209 MessageVLT0212 Message VLT0213 MessageVLT0215 Message VLT0214 MessageVLT0216 Message VLT0219 Message Error Code Message Information VLT0218VLT0220 Message VLT0221 MessageVLT0224 Message VLT0222 MessageVLT0225 Message VLT0226 MessageVLT0227 Message Error Code Message Information Details ActionVLT0228 Message VLT0230 MessageMezzanine card number name voltage is outside of range Alert Messages Diagnostic Messages132 Visit support.dell.com Contacting Dell
Related manuals
Manual 12 pages 5.14 Kb Manual 140 pages 32.84 Kb Manual 143 pages 47.32 Kb

M620 specifications

The Dell M620 is a high-performance blade server designed to deliver exceptional computing power and efficiency for enterprise applications. As part of the Dell PowerEdge M-Series lineup, the M620 is known for its flexibility, scalability, and robust feature set, making it an ideal choice for data centers looking to optimize their server infrastructure.

One of the main features of the Dell M620 is its advanced processing capabilities. It supports dual Intel Xeon E5-2600 series processors, which enable users to take advantage of the latest multi-core technology to handle demanding workloads. With support for up to 768 GB of RAM, the M620 ensures efficient memory allocation for resource-intensive applications, enhancing overall performance.

The blade server boasts a modular design that allows it to fit seamlessly into the Dell PowerEdge M1000e chassis, which can house multiple blade servers. This design not only saves physical space but also optimizes power and cooling resources, significantly reducing total cost of ownership. The M620's thermal efficiency is further enhanced by its intelligent fan control, which adjusts airflow based on workload requirements, ensuring optimal operating conditions.

In terms of storage, the Dell M620 offers flexibility with support for up to two hot-swappable hard drives. This feature facilitates easy upgrades and maintenance, allowing organizations to manage data growth efficiently. The server also supports the latest RAID technology, which provides data redundancy and enhances reliability, essential for critical business operations.

Networking capabilities are another standout feature of the M620. It provides multiple options for integrated networking, including support for up to four 1Gb Ethernet ports or 10Gb Ethernet options. This enables fast and reliable connectivity, which is crucial for data-intensive applications and virtualization environments.

Security is also a key consideration in the design of the Dell M620. It comes equipped with various security features, including Trusted Platform Module (TPM), secure BIOS, and systems management tools, ensuring a secure computing environment.

Overall, the Dell M620 blade server combines powerful processing capabilities, expandable memory, efficient design, versatile storage options, and robust networking solutions. These characteristics make it a compelling choice for organizations seeking to enhance their IT infrastructure, drive innovation, and meet the challenges of today’s digital landscape. With Dell's commitment to quality and performance, the M620 continues to be a valuable solution for enterprise customers.