Dell T320 owner manual Power connector

Page 68

Figure 30. Cabling—x8 Hard-Drive Backplane

 

1. power connector

5. SAS A connector on backplane

2.

SAS A connector on system board

6. backplane power connector

3.

I2C connector on system board

 

4.

I2C connector on backplane

 

68

Image 68
Contents Regulatory Model E20S Series Regulatory Type E20S001 Dell Inc Contents Installing System Components Page Converting The System From Tower Mode To Rack Mode 125Troubleshooting Your System Using System DiagnosticsJumpers And Connectors Technical Specifications169 Front-Panel Features And Indicators-Tower Mode About Your SystemPage Indicator, Button, or Icon Description Connector Interface ACPI-compliant operating systemsUp to sixteen 2.5 inch hot-swappable hard drives To the system is turned off Front-Panel Features And Indicators-Rack Mode Front-Panel Features and IndicatorsLCD Panel Features Setup Menu Home ScreenButton Description Option Description IDRACDiagnostic Indicators View MenuHard-drive Indicator Condition Electrical Indicator ConditionHard-Drive Indicator Patterns Predicted drive failure SecondsBack-Panel Features And Indicators Redundant power Up to two 495 W or 750 W ACPCIe expansion card slots Green Link indicator is NIC Indicator CodesPower Indicator Codes For Redundant Power Supply Power Indicator Codes For Non-Redundant Power Supply Other Information You May Need Page Choosing The System Boot Mode Entering System Setup System Setup OptionsResponding To Error Messages Using The System Setup Navigation KeysSystem Information Screen System Setup Main ScreenSystem Bios Screen Memory Settings Screen Processor Settings ScreenOption is set to Enabled Prefetcher option is set to EnabledExecute Disable Execute Disable option is set to EnabledSata Settings Screen Boot Settings ScreenIntegrated Devices Screen Serial Communications ScreenSystem Profile Settings Screen System Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Operating With a Setup Password EnabledEntering The Uefi Boot Manager Using The Boot Manager Navigation KeysBoot Manager Screen Exits the Boot Manager and proceeds with system bootIDRAC Settings Utility Uefi Boot MenuEntering The iDRAC Settings Utility Embedded System ManagementChanging The Thermal Settings Page Front Bezel Optional Installing The Front BezelRecommended Tools System Feet-Tower Mode Removing The Front BezelRemoving The System Feet Wheel Assembly Optional-Tower ModeInstalling The System Feet Removing The Wheel Assembly Removing and Installing the Wheel AssemblyOpening The System Installing The Wheel AssemblyOpening And Closing The System Inside The System Closing The SystemPower interposer board System feet PCIe card holder optional Slot SAS tape drive or blank Slot Sata optical drive or PowerVault RD1000Optical Drives And Tape Drives Optional Removing The Optical Drive Or Tape Drive Optical drive Tape drive Release latch Connector for power cable extension Removing The Cooling Shroud Installing The Optical Drive Or Tape DriveCooling Shroud Installing The Cooling Shroud Removing and Installing the Cooling ShroudHard Drives-Hot-Swappable Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveRemoving a 3.5 Inch Hard-Drive Blank Installing a 2.5 Inch Hard-Drive BlankRemoving a 2.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive Blank Removing and Installing a 3.5 Inch Hard-Drive BlankScrews Inch hard-drive adapter Inch hard drive Hard Drives-Cabled Installing and Removing the Internal Hard-Drive Bay Removing The Internal Hard-Drive BayInstalling The Internal Hard-Drive Bay Removing a Cabled Hard DriveInstalling a Cabled Hard Drive Removing and Installing a Cabled Hard DriveHard-Drive Backplane Removing The Hard-Drive BackplaneX8 hard-drive backplane Release pin Hooks Connectors on an x8 Hard-Drive Backplane Power connector X16 hard-drive backplane Release pin Hooks Backplane power connector Primary SAS connectors a and B Connectors on an x16 Hard-Drive BackplaneInstalling The Hard-Drive Backplane Cabling-x16 Hard-Drive Backplane With Expansion CardFour-Slot Hard-Drive Blank Removing a Four-Slot Hard-Drive BlankInstalling a Four-Slot Hard-Drive Blank System Memory1333, 1066, Dual rank Memory Socket LocationsGeneral Memory Module Installation Guidelines Mode-Specific GuidelinesOrganization, Sample Memory ConfigurationsDimm Size in GB Number of DIMMs Dimm Rank Removing Memory Modules Installing Memory Modules Removing and Installing a Memory ModuleCooling Fans Removing The Internal Cooling FanRemoving and Installing the Internal Cooling Fan Installing The Internal Cooling Fan Cabling-Internal Cooling FanRemoving The External Cooling Fan Back of the system chassis Upper hook Lower hooks Installing The External Cooling Fan Internal USB Memory Key OptionalReplacing The Internal USB Key Replacing the Internal USB KeyPCIe Card Holder Optional Removing The PCIe Card HolderInstalling The PCIe Card Holder Expansion Card Installation GuidelinesExpansion Cards Expansion Card SlotCard Priority Card Type Slot Priority Maximum Allowed GPU Card Installation GuidelinesRemoving An Expansion Card Installing An Expansion Card Removing and Installing the Expansion CardRemoving a GPU Card Installing a GPU Card Removing and Installing the GPU CardIDRAC Ports Card Removing The iDRAC Ports CardInstalling The iDRAC Ports Card Removing and Installing the iDRAC Ports CardRemoving An Internal Dual SD Module Internal Dual SD ModuleReplacing An SD vFlash Card Installing An Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Processors Removing a ProcessorRemoving and Installing the Heat Sink Installing a Processor Removing and Installing a ProcessorRedundant AC Power Supply Removing a Redundant AC Power SupplyInstalling a Redundant AC Power Supply Removing and Installing a Redundant AC Power SupplyRemoving The Power Supply Blank Installing The Power Supply BlankReplacing The Power Supply Divider Removing and Installing the Power-Supply DividerNon-Redundant AC Power Supply Removing a Non-Redundant AC Power SupplyPower supply unit cage Removing The Power Interposer Board Power Distribution Board And Power Interposer BoardInstalling a Non-Redundant AC Power Supply Release latch Screws P6 cable connector 107 System Battery Installing The Power Interposer BoardReplacing The Power Distribution Board Replacing The System BatteryControl-Panel Assembly Removing and Installing the System BatteryRemoving The Control-Panel Assembly Control-panel assembly cable connector Information tag Tabs 112 Installing The Control-Panel Assembly Removing The Control PanelControl panel 114 Installing The Control Panel Page Control-panel board Screws Control-panel assembly 117 Removing The LCD Module Installing The LCD Module Removing and Installing the LCD ModuleRemoving The VGA Module-Rack Mode Removing and Installing the VGA ModuleRemoving The System Board Installing The VGA Module-Rack ModeSystem Board Installing The System Board Removing the System BoardPage 124 Converting The System From Tower Mode To Rack Mode Safety InstructionsRemoving and Installing The System Top Cover Rack Installation Removing and Installing the Rack Ears128 Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a Wet System Troubleshooting a Serial I/O DeviceTroubleshooting a NIC Troubleshooting a Damaged System Troubleshooting Redundant Power Supplies Troubleshooting The System BatteryTroubleshooting a Non-Redundant Power Supply Troubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Troubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting An Optical Or Tape Drive Troubleshooting a Hard Drive Troubleshooting Expansion CardsTroubleshooting Processor 138 Running The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics System Diagnostic Controls Least one event description is recordedSystem Board Jumper Settings JumperSystem Board Connectors Connector DescriptionDisabling a Forgotten Password IntrusionPage Processor Expansion BusExpansion slots MemoryConnectors Back DrivesFront InternalVideo ConnectorsExpanded Operating Temperature Environmental Temperature Temperature Continuous OperationRelative Humidity Maximum VibrationEnvironmental Gaseous Contamination150 System Error Messages LCD MessagesViewing LCD Messages Removing LCD MessagesError Code AMP0302 MessageDetails AMP0303 MessageASR0003 Message BAT0002 MessageBAT0017 Message CPU0000 MessageCPU0010 Message CPU0023 MessageCPU0204 Message CPU0700 MessageCPU0704 Message Exception is external to the processorCPU0703 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0000 Message MEM0001 MessageMEM0007 Message MEM0701 MessageMEM1208 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePCI1320 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePST0128 Message PST0129 MessagePSU0001 Message PSU0002 MessagePSU0006 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0034 Message PSU0035 MessagePSU0036 Message PSU0037 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Security may be compromisedIssues persists, contact support FailedFailures TMP0121 MessageDiagnostic Messages Alert Messages168 Getting Help Contacting Dell
Related manuals
Manual 9 pages 13.91 Kb Manual 167 pages 13.94 Kb

T320 specifications

The Dell PowerEdge T320 is a versatile tower server designed to meet the needs of small to medium-sized businesses. It is engineered to handle a variety of workloads, from data storage and virtualization to basic web serving and productivity applications. With a blend of performance, reliability, and expandability, the T320 serves as a robust solution for organizations looking to enhance their IT infrastructure.

One of the standout features of the T320 is its use of Intel's Xeon E5-2400 series processors, which deliver outstanding computing power and efficiency. Supporting up to two processors, this tower server can be configured to handle demanding tasks effectively. The ability to support up to 768GB of DDR3 memory through its 12 DIMM slots ensures that the T320 can manage memory-intensive applications, making it well-suited for data analytics and virtualization.

Storage capacity is another significant advantage of the T320. It comes equipped with up to eight 3.5-inch drives, which can be configured for RAID to enhance data protection and performance. The server supports both SATA and SAS drives, allowing for a range of options when it comes to speed and capacity. Additionally, a built-in PERC controller facilitates RAID configuration and monitoring, providing an additional layer of security for critical data.

The T320's design focuses on scalability, featuring several expansion slots for PCIe add-in cards. This allows businesses to grow their server capabilities over time, adding components such as graphics cards or network interface cards as needed. Furthermore, the server includes integrated 1GB Ethernet ports, facilitating easy connectivity within a network.

In terms of management and monitoring, the Dell PowerEdge T320 features the integrated Dell Remote Access Controller (iDRAC), which provides out-of-band management capabilities. This allows IT administrators to remotely manage and monitor server health and performance, reducing the need for physical access and streamlining maintenance tasks.

Moreover, the T320 emphasizes energy efficiency. With Dell's Energy Smart technologies, the server is designed to minimize power consumption and heat production while maintaining high performance. This not only contributes to lower operational costs but also supports environmentally friendly practices.

Overall, the Dell PowerEdge T320 is an efficient and reliable tower server that provides businesses with the performance and flexibility needed to manage various workloads. Its robust features, combined with Dell's commitment to quality and service, make it a valuable asset for companies looking to improve their IT operations.