Dell T320 owner manual Installing An Internal Dual SD Module

Page 95

4.Locate the internal dual SD module on the system board.

5.If applicable, remove the SD card(s).

6.Pull out the internal dual SD module from the system board.

7.Close the system.

8.If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.

9.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Figure 47. Removing and Installing the Internal Dual SD Module

1.SD card connector on system board

2.SD card slot 1

3.SD card slot 2

4.SD card

Installing An Internal Dual SD Module

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and peripherals.

2.If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.

NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable surface with the wheel assembly extending off the edge of the surface.

3.Open the system.

4.Locate the internal dual SD module connector on the system board.

5.Align the connectors on the system board with the connectors on the internal dual SD module.

6.Press the internal dual SD module until it is seated on the system board.

95

Image 95
Contents Regulatory Model E20S Series Regulatory Type E20S001 Dell Inc Contents Installing System Components Page 125 Converting The System From Tower Mode To Rack ModeTechnical Specifications Troubleshooting Your SystemUsing System Diagnostics Jumpers And Connectors169 About Your System Front-Panel Features And Indicators-Tower ModePage Interface ACPI-compliant operating systems Indicator, Button, or Icon Description ConnectorUp to sixteen 2.5 inch hot-swappable hard drives To the system is turned off Front-Panel Features and Indicators Front-Panel Features And Indicators-Rack ModeLCD Panel Features Option Description IDRAC Setup MenuHome Screen Button DescriptionView Menu Diagnostic IndicatorsElectrical Indicator Condition Hard-drive Indicator ConditionHard-Drive Indicator Patterns Seconds Predicted drive failureRedundant power Up to two 495 W or 750 W AC Back-Panel Features And IndicatorsPCIe expansion card slots Green Link indicator is NIC Indicator CodesPower Indicator Codes For Redundant Power Supply Power Indicator Codes For Non-Redundant Power Supply Other Information You May Need Page Choosing The System Boot Mode Using The System Setup Navigation Keys Entering System SetupSystem Setup Options Responding To Error MessagesSystem Information Screen System Setup Main ScreenSystem Bios Screen Processor Settings Screen Memory Settings ScreenExecute Disable option is set to Enabled Option is set to EnabledPrefetcher option is set to Enabled Execute DisableBoot Settings Screen Sata Settings ScreenSerial Communications Screen Integrated Devices ScreenSystem Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning a System And/Or Setup Password Operating With a Setup Password Enabled Using Your System Password To Secure Your SystemExits the Boot Manager and proceeds with system boot Entering The Uefi Boot ManagerUsing The Boot Manager Navigation Keys Boot Manager ScreenEmbedded System Management IDRAC Settings UtilityUefi Boot Menu Entering The iDRAC Settings UtilityChanging The Thermal Settings Page Front Bezel Optional Installing The Front BezelRecommended Tools Removing The Front Bezel System Feet-Tower ModeRemoving The System Feet Wheel Assembly Optional-Tower ModeInstalling The System Feet Removing and Installing the Wheel Assembly Removing The Wheel AssemblyOpening The System Installing The Wheel AssemblyOpening And Closing The System Closing The System Inside The SystemPower interposer board System feet PCIe card holder optional Slot SAS tape drive or blank Slot Sata optical drive or PowerVault RD1000Optical Drives And Tape Drives Optional Removing The Optical Drive Or Tape Drive Optical drive Tape drive Release latch Connector for power cable extension Removing The Cooling Shroud Installing The Optical Drive Or Tape DriveCooling Shroud Removing and Installing the Cooling Shroud Installing The Cooling ShroudRemoving a Hot-Swap Hard Drive Hard Drives-Hot-SwappableRemoving and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a 3.5 Inch Hard-Drive Blank Installing a 2.5 Inch Hard-Drive BlankRemoving a 2.5 Inch Hard-Drive Blank Removing and Installing a 3.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive BlankScrews Inch hard-drive adapter Inch hard drive Hard Drives-Cabled Removing The Internal Hard-Drive Bay Installing and Removing the Internal Hard-Drive BayRemoving a Cabled Hard Drive Installing The Internal Hard-Drive BayRemoving and Installing a Cabled Hard Drive Installing a Cabled Hard DriveRemoving The Hard-Drive Backplane Hard-Drive BackplaneX8 hard-drive backplane Release pin Hooks Connectors on an x8 Hard-Drive Backplane Power connector X16 hard-drive backplane Release pin Hooks Connectors on an x16 Hard-Drive Backplane Backplane power connector Primary SAS connectors a and BCabling-x16 Hard-Drive Backplane With Expansion Card Installing The Hard-Drive BackplaneRemoving a Four-Slot Hard-Drive Blank Four-Slot Hard-Drive BlankSystem Memory Installing a Four-Slot Hard-Drive BlankMemory Socket Locations 1333, 1066, Dual rankMode-Specific Guidelines General Memory Module Installation GuidelinesOrganization, Sample Memory ConfigurationsDimm Size in GB Number of DIMMs Dimm Rank Removing Memory Modules Removing and Installing a Memory Module Installing Memory ModulesRemoving The Internal Cooling Fan Cooling FansRemoving and Installing the Internal Cooling Fan Cabling-Internal Cooling Fan Installing The Internal Cooling FanRemoving The External Cooling Fan Back of the system chassis Upper hook Lower hooks Internal USB Memory Key Optional Installing The External Cooling FanReplacing the Internal USB Key Replacing The Internal USB KeyRemoving The PCIe Card Holder PCIe Card Holder OptionalExpansion Card Slot Installing The PCIe Card HolderExpansion Card Installation Guidelines Expansion CardsCard Priority Card Type Slot Priority Maximum Allowed GPU Card Installation GuidelinesRemoving An Expansion Card Removing and Installing the Expansion Card Installing An Expansion CardRemoving a GPU Card Removing and Installing the GPU Card Installing a GPU CardRemoving The iDRAC Ports Card IDRAC Ports CardRemoving and Installing the iDRAC Ports Card Installing The iDRAC Ports CardRemoving An Internal Dual SD Module Internal Dual SD ModuleReplacing An SD vFlash Card Removing and Installing the Internal Dual SD Module Installing An Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Removing a Processor ProcessorsRemoving and Installing the Heat Sink Removing and Installing a Processor Installing a ProcessorRemoving a Redundant AC Power Supply Redundant AC Power SupplyRemoving and Installing a Redundant AC Power Supply Installing a Redundant AC Power SupplyInstalling The Power Supply Blank Removing The Power Supply BlankRemoving and Installing the Power-Supply Divider Replacing The Power Supply DividerRemoving a Non-Redundant AC Power Supply Non-Redundant AC Power SupplyPower supply unit cage Removing The Power Interposer Board Power Distribution Board And Power Interposer BoardInstalling a Non-Redundant AC Power Supply Release latch Screws P6 cable connector 107 Replacing The System Battery System BatteryInstalling The Power Interposer Board Replacing The Power Distribution BoardRemoving and Installing the System Battery Control-Panel AssemblyRemoving The Control-Panel Assembly Control-panel assembly cable connector Information tag Tabs 112 Removing The Control Panel Installing The Control-Panel AssemblyControl panel 114 Installing The Control Panel Page Control-panel board Screws Control-panel assembly 117 Removing The LCD Module Removing and Installing the LCD Module Installing The LCD ModuleRemoving and Installing the VGA Module Removing The VGA Module-Rack ModeRemoving The System Board Installing The VGA Module-Rack ModeSystem Board Removing the System Board Installing The System BoardPage 124 Safety Instructions Converting The System From Tower Mode To Rack ModeRemoving and Installing The System Top Cover Removing and Installing the Rack Ears Rack Installation128 Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a Wet System Troubleshooting a Serial I/O DeviceTroubleshooting a NIC Troubleshooting a Damaged System Troubleshooting Redundant Power Supplies Troubleshooting The System BatteryTroubleshooting a Non-Redundant Power Supply Troubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Troubleshooting An SD Card Troubleshooting An Internal USB KeyTroubleshooting An Optical Or Tape Drive Troubleshooting Expansion Cards Troubleshooting a Hard DriveTroubleshooting Processor 138 Running The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper System Board Jumper SettingsConnector Description System Board ConnectorsIntrusion Disabling a Forgotten PasswordPage Memory ProcessorExpansion Bus Expansion slotsInternal Connectors BackDrives FrontVideo ConnectorsExpanded Operating Temperature Maximum Vibration Environmental TemperatureTemperature Continuous Operation Relative HumidityGaseous Contamination Environmental150 Removing LCD Messages System Error MessagesLCD Messages Viewing LCD MessagesAMP0303 Message Error CodeAMP0302 Message DetailsCPU0000 Message ASR0003 MessageBAT0002 Message BAT0017 MessageCPU0700 Message CPU0010 MessageCPU0023 Message CPU0204 MessageCPU0704 Message Exception is external to the processorCPU0703 Message Details Fan operating speed is out of range Action If the issue persists, see Getting HelpAction Reinstall or reconnect the hardware HWC2003 Message FAN0000 MessageMEM0701 Message MEM0000 MessageMEM0001 Message MEM0007 MessagePCI1304 Message MEM1208 MessageMEM8000 Message PCI1302 MessagePCI1360 Message PCI1320 MessagePCI1342 Message PCI1348 MessagePSU0002 Message PST0128 MessagePST0129 Message PSU0001 MessagePSU0032 Message PSU0006 MessagePSU0016 Message PSU0031 MessagePSU0037 Message PSU0034 MessagePSU0035 Message PSU0036 MessageSystem power consumption PSU1201 Message Power supply redundancy is lost DetailsSystem power inventory change Configuration and power consumptionRFM2002 Message RFM1014 MessageRFM1201 Message RFM2001 MessageSecurity may be compromised SEL0006 Message All event logging is disabled DetailsAppear if the user disabled event logging Power. If problem persists call supportTMP0121 Message Issues persists, contact supportFailed FailuresAlert Messages Diagnostic Messages168 Contacting Dell Getting Help
Related manuals
Manual 9 pages 13.91 Kb Manual 167 pages 13.94 Kb

T320 specifications

The Dell PowerEdge T320 is a versatile tower server designed to meet the needs of small to medium-sized businesses. It is engineered to handle a variety of workloads, from data storage and virtualization to basic web serving and productivity applications. With a blend of performance, reliability, and expandability, the T320 serves as a robust solution for organizations looking to enhance their IT infrastructure.

One of the standout features of the T320 is its use of Intel's Xeon E5-2400 series processors, which deliver outstanding computing power and efficiency. Supporting up to two processors, this tower server can be configured to handle demanding tasks effectively. The ability to support up to 768GB of DDR3 memory through its 12 DIMM slots ensures that the T320 can manage memory-intensive applications, making it well-suited for data analytics and virtualization.

Storage capacity is another significant advantage of the T320. It comes equipped with up to eight 3.5-inch drives, which can be configured for RAID to enhance data protection and performance. The server supports both SATA and SAS drives, allowing for a range of options when it comes to speed and capacity. Additionally, a built-in PERC controller facilitates RAID configuration and monitoring, providing an additional layer of security for critical data.

The T320's design focuses on scalability, featuring several expansion slots for PCIe add-in cards. This allows businesses to grow their server capabilities over time, adding components such as graphics cards or network interface cards as needed. Furthermore, the server includes integrated 1GB Ethernet ports, facilitating easy connectivity within a network.

In terms of management and monitoring, the Dell PowerEdge T320 features the integrated Dell Remote Access Controller (iDRAC), which provides out-of-band management capabilities. This allows IT administrators to remotely manage and monitor server health and performance, reducing the need for physical access and streamlining maintenance tasks.

Moreover, the T320 emphasizes energy efficiency. With Dell's Energy Smart technologies, the server is designed to minimize power consumption and heat production while maintaining high performance. This not only contributes to lower operational costs but also supports environmentally friendly practices.

Overall, the Dell PowerEdge T320 is an efficient and reliable tower server that provides businesses with the performance and flexibility needed to manage various workloads. Its robust features, combined with Dell's commitment to quality and service, make it a valuable asset for companies looking to improve their IT operations.