Connecting Cables
Installation
Connecting Cables (not included)
Power wire and wiring are very important to the performance of the inverter. Because the inverter has a low voltage, high current input, low resistance wiring is essential between the battery and inverter. This is so it can deliver the maximum amount of energy to the load.
Use only copper wire. Aluminum wire has about 13 more resistance than copper wire of the same size, plus it is difficult to make good, low-resistance connections to aluminum wire.
We recommend two #4 AWG copper cables (90°C insulation rating) as the minimum size for connections between the battery and inverter.
Keep the cable length as short as possible, no more than 4 ft. (1.5 meters). This will keep the voltage drop to a minimum.
If the cable has too much voltage drop, the inverter may shut down when drawing higher currents because voltage at the inverter may drop below 10 volts. If you must use longer cables, choose thicker cables, such as #2 AWG, and trim the ends of the cable to fit the terminals.
To Connect the Cables Between the Inverter and the Battery:
1. Turn the On/Off Switch on the inverter to the Off position. If the power source is a DC power supply, switch it Off as well.
On/Off Switch to Off
2. On the end of the cable that connects to the inverter, strip back the insulation about 12 inch (1.25 cm), exposing the bare copper conductor.
8 English

Connecting Cables

Installation

Strip the Insulation

3.Connect cables to the Power Input Terminals on right side panel of the inverter. The red terminals are positive

(+) and the black terminals are negative (-). Insert the bare ends of the cables into the terminals and tighten the screws to clamp the wires safely.

Insert Bare Cables

4.Connect cables to the power source:

a.Connect each cable from the Negative (Black) Terminals of inverter to the Negative Terminal of the power source. Make a secure connection.

b.Connect each cable from the Positive (Red) Terminals of the inverter to the Positive Terminal of the power source (the battery’s main fuse or the battery selector switch, if you are using one). Make a secure connection.

Connect Cables

Continued...

Nothing comes close to a Cobra9

Image 7
Contents Hours a day, 7 days a week 773-889-3087 phone Our Thanks To YouTable of Contents Important Safety Information Important Safety InformationGeneral Precautions Cobra 2500W Output Waveform Quick Evaluation Before Installation Quick Evaluation Before InstallationBe Sure to Have on Hand Mounting Installation RequirementsConnect cables to the power source Connecting CablesConnecting Cables To Determine the Battery Ampere-Hour Capacity You Require Power ConsumptionGround Wiring Power ConsumptionOn/Off Switch to On On/Off Switch to Off Remote On/Off SwitchRemote On /Off Switch not included Operating Limits Operating Limits Power OutputInput Voltage Solution Troubleshooting GuideSpecifications Troubleshooting GuideMaintenance WarrantyMaintenance Product Service Limited 1-Year WarrantyItem # Cost Each Qty Amount Accessories Order Form