Connecting Cables

Installation

You might observe a spark when you make this connection, since current can flow to charge capacitors in the inverter.

All power connections to your Cobra® inverter must be Positive To Positive and Negative To Negative.

CAUTION Electrical installations must meet local and national wiring codes, and should be performed by a qualified electrician.

CAUTION Do not connect the inverter and another AC source (such as a generator or utility power) to the AC wiring at the same time. The inverter will be damaged if its output is connected to AC voltage from another source. Damage can even occur if the inverter is switched Off.

CAUTION Do not connect the inverter to an AC branch circuit that has high-power consumption loads. It will not operate electric heaters, air conditioners, stoves, and other electrical appliances that consume more than 2500 watts.

CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation.

CAUTION Reverse polarity connections (positive to negative) will blow internal fuses in the inverter and may permanently damage the unit. Such damage is not covered by the warranty.

CAUTION We recommend a main fuse in the battery’s positive cable to protect against DC wiring short circuits (external to the inverter). The fuse should be as close to the battery as possible. We recommend a Buss Fuse ANL-250 or equivalent. The specific fuse ampere rating should be sized to allow operation of all your DC powered equipment.

CAUTION Remove any jewelry (watch, ring, etc.). Be careful not to short circuit the battery with any metallic object (wrench, etc.).

Connecting Cables

Installation

WARNING If you are making a permanent AC connection to the inverter, make sure that the AC wiring steps are performed before any DC wiring is done. (DC hook-up energizes internal components, regardless of the position of the On/ Off Switch). Working on AC connections in such a circumstance may result in an electric shock.

WARNING 115 volt AC power is potentially lethal. Do not work on AC wiring when it is connected to the inverter (even if it is switched Off) unless the DC power source is physically disconnected from the inverter. Also, do not work on AC wiring if it is connected to another AC power source such as a generator or the utility line.

WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter.

Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection.

NOTE If only one power source is used, connect both cables from the negative terminal of the inverter to the negative terminal of the power source. Then connect both cables from the positive terminals of the inverter to the positive terminal of the power source.

10 English

Nothing comes close to a Cobra11

Image 8
Contents Our Thanks To You Hours a day, 7 days a week 773-889-3087 phoneTable of Contents General Precautions Important Safety InformationImportant Safety Information Cobra 2500W Output Waveform Be Sure to Have on Hand Quick Evaluation Before Installation Quick Evaluation Before Installation Installation Requirements MountingConnecting Cables Connect cables to the power sourceConnecting Cables Power Consumption Ground WiringPower Consumption To Determine the Battery Ampere-Hour Capacity You RequireRemote On /Off Switch not included Remote On/Off SwitchOn/Off Switch to On On/Off Switch to Off Input Voltage Operating Limits Power OutputOperating Limits Troubleshooting Guide SpecificationsTroubleshooting Guide SolutionWarranty Maintenance Product ServiceLimited 1-Year Warranty MaintenanceAccessories Order Form Item # Cost Each Qty Amount