Banner American Products Wireless Network SureCross Accessories, Sensors, AC Power Supply Options

Page 24

SureCrossAccessories

QT50U

MINI-BEAM

Sensors

Optimized for use with FlexPower™ Systems

Model Number

QT50ULBQ6-75390

SM312LPQD-76885

SM312DQD-75904

Supply Voltage

FlexPower™

Description

U-GAGE®Ultrasonic

MINI-BEAM®Photoelectric

Sensing Mode

Range

Output Type

Connection

 

 

 

Selectable:

5-pin

 

 

200 mm - 8 m

0 to 10V dc or

 

 

Euro QD

 

 

 

4 to 20 mA

 

 

 

 

P

3 m

Bipolar

4-pin

NPN/PNP

Euro QD

POLAR RETRO

 

 

 

 

 

 

 

 

 

 

 

380 mm

Bipolar

4-pin

 

 

NPN/PNP

Euro QD

DIFFUSE

 

 

 

 

 

 

 

 

 

Data Sheet*

70137

69943

* Data sheets are for standard product, contact factory for additional supporting literature.

M18

T30

K50L

EZ-LIGHTIndicators

Multi-Color, 7-function

Model Number

Construction

M18GRY2PQ

18 mm mount

Nickel-plated brass

 

 

 

T30GRY2PQ

30 mm mount

Thermoplastic polyester

 

 

 

K50LGRY2PQ

30 mm mount

Thermoplastic polyester

 

 

 

Connection

4-pin Euro QD

LED Function

Choose Red, Yellow or Green ON, flashing or alternating

Other Colors

Available

Inputs

Data Sheet

PNP

121902

K80L

DX81

FlexPowerSupplies

K80LGRY2PQ

Model Number

DX81

DX121

Flat or DIN mount

Thermoplastic polyester

Voltage Supplied

FlexPower Battery

Module to supply

FlexPower Node

Description

Connection

Module driven by one lithium primary battery**

5-pin Euro QD

Module driven by six lithium primary batteries**

Housing

Data Sheet

131596

IP67

131628

**Replacement lithium primary battery model number is BWA-BATT-001

EZAC

AC Power

Supply

Options

Model Number

Voltage Supplied

Description

SPS101Q

 

Converts 105 - 130V ac, 60 Hz to 12V dc

 

(SPST e/m Relay Output)

 

12V dc @ 120 mA max

 

 

SPS101SQ

Converts 105 - 130V ac, 60 Hz to 12V dc

 

 

(Optically Isolated SPST Solid-state Output)

 

 

EZAC-E-QE5-QS5

24V dc @ 700 mA

Converts 100 - 230V ac to 24V dc

(no output)

 

 

PS24W

24V dc @ 500 mA

Converts 100 - 240V ac to 24V dc

North America (wall plug)

 

 

 

 

 

Connection

Sensor Connection:

5-pin Euro QD

AC Power Connection:

5-pin Mini QD

5-pin Euro QD

Housing

Data Sheet

IP54

66959

 

 

IP65

120321

Non-

 

industrial

(not sealed)

 

Expandable

DX85

Remote I/O

Model Number

I/O Functionality

DX85-4P4M2M2

2 Analog IN, 2 Analog OUT (0-20 mA);

4 Discrete IN (sourcing),

 

4 Discrete OUT (sourcing)

DX85-6P6

6 Discrete IN (sourcing),

6 Discrete OUT (sourcing)

 

 

 

Description

Modbus RTU Slave

Expansion I/O Modules; used to expand Gateway I/O capacity

Housing

IP67

Data Sheet

131629

131599

24

More information online at bannerengineering.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Image 24
Contents Page SureCross wireless from the most reliable name in sensing ContentsWireless Terms Add Monitoring. Add Control Where You Need it Most Introducing SureCross. Sensing unpluggedEasy to Apply Wireless Modules Go Where Other Systems Can’t 4GHzPage SureCross. Purpose-built by Banner Wait is overTests Signal Integrity Locally Robust. Reliable. SecureEngineered Simplicity Predictable. Reliable. RepeatablePage Wireless Monitoring Retrofit in a Pre-Certified Facility Motor Temperature Monitoring and ControlProcess Control and Monitoring Monitoring of Rotating EquipmentGateway to Error-Proofing Manufacturing Factory AutomationPage Agriculture and Water Management Remote and Field-Based Monitoring is Now a RealityEnvironmental Temperature and Humidity Monitoring Air Flow/Ventilation MonitoringEthanol Plant Water Monitoring Municipal Water MonitoringRail Transport Car Positioning Parking Kiosk Access and Control Traffic Monitoring and ControlAutomated Car Wash Detection Loading Dock Occupancy MonitoringModular Monitoring Capabilities Security/Access Monitoring Refrigeration System Temperature MonitoringEnergy Monitoring/Management Retail Traffic AnalysisNeed to be wireless? SureCross Gateway and Node PossibilitiesSureCross Configuration Engineered Your Way SureCross Configured KitsSureCross Plug-and-Play Configured Kits Discrete†Analog SystemsLine Powered Nodes SureCross Gateway and Node ModelsGateways SureCross Accessories AC Power Supply OptionsSensors FlexPower Solar Modules MountingHardware BracketSureCross Antennas & Cabling Options High-Gain YagiHigh-Performance Omni Antenna Adapter CablesSureCross Specifications & Dimensions Dimension DrawingsGeneral Radio ComplianceSensor Supplemental Information Default IP Address Click OKSpecifiy an IP Address Click Start Settings Control Panel