AMI BIOS will automatically display the following information:

CPU1 VCORE/CPU2 VCORE (*for 2U systems),

3.3V Vcc(V), +5 Vin, 12V Vcc(V), -12V Vcc (V), DRAM VTT, 1.2V Vcc, 2.5V for DIMM, 1.5V Standby Power, 5V Standby, 3.3V Standby.

Fan Speed Control Modules:

This feature allows the user to decide how the system controls the speeds of the onboard fans. If the option is set to "3-pin fan", the fan speed is controlled based upon the CPU die temperature. When the CPU die tempera- ture is higher, the fan speed will be higher as well. If the option is set to "4- pin", the fan speed will be controlled by the Thermal Management Settings pre-configured by the user at this feature. Select "3-pin" if your chassis came with 3-pin fan headers. Select "4-pin" if your chassis came with 4-pin fan headers. Select "Workstation" if your system is used as a Workstation. Select "Server" if your system is used as a Server. Select "Disable" to disable the fan speed control function to allow the onboard fans to run at the full speed (12V) at all time. The Options are: 1. Disable, 2. 3-pin (Server), 3. 3-pin (Workstation), 4. 4-pin (Server), 5. 4-pin (Workstation).

Fan1 Speed to Fan6 Speed

4-4 Boot Settings

This feature allows the user to configure the following items:

BIOS SETUP UTILITY

Main Advanced Boot Security Exit

.

Boot Settings

Boot Settings Configuration

Boot Device Priority

Configure settings during System Boot

Removable Drives

CD/DVD Drives

 

 

 

 

Select Screen

 

 

 

 

 

 

 

 

Select Item

+-

Change Field

Tab

Select Field

F1

General Help

F10

Save and Exit

ESC

Exit

VOZ-53 (C)Copyright 1985-2002, American Megatrends, Inc.

4-18

Image 70
Contents Super Page About This Manual Manual OrganizationTable of Contents Appendices Advanced Setup Boot SetupIntroduction Page Checklist OverviewEurope Contacting SupermicroHeadquarters Asia-PacificSuper X6DVA-4G/X6DVA-EG Image Super X6DVA-4G Quick Reference X6DVA-4G/X6DVA-EG Jumper Description Default SettingConnector Description Please refer to for pin definitionsChipset Motherboard FeaturesM o r y Expansion SlotsOnboard I/O Acpi FeaturesDimensions OtherBlock Diagram of the E7320 Lindenhurst-VS Chipset 6300ESB ICH System Features Chipset OverviewEnvironmental Temperature Control Special FeaturesRecovery from AC Power Loss PC Health MonitoringCPU Overheat LED and Control Acpi FeaturesAuto-Switching Voltage Regulator for the CPU Core TM2/CPU VRM OverheatMicrosoft OnNow Slow Blinking LED for Suspend-State IndicatorMain Switch Override Mechanism External Modem Ring-On WORSuper I/O Power SupplyWake-On-LAN WOL Page Static-Sensitive Devices PrecautionsUnpacking CPU Installation PGA Processor and Heatsink InstallationInstalling the CPU Mounting Plate and Retention Bracket CPU Mounting PlateTo Un-install the Heatsink Heatsink InstallationHandle with care PGA604 Socket Empty and with Processor Installed Mounting the Motherboard in the Chassis Installing DIMMsDimm Installation See Figure Memory SupportI/OPorts/Control Panel Connectors I/O Port Locations and DefinitionsJF1 Header Pins Front Control PanelATX Power Connector Connecting CablesProcessor Power Connector NMI Button Pin Definitions Power LEDNMI Button Pwrled Pin DefinitionsHDD LED Pin Definitions NIC1/NIC2 LED IndicatorsNIC1 LED Pin NIC2 LED Pin Definitions Overheat/Fan Fail LED Power Fail LEDHealth LED PWR Fail LED Reset PWR Button Reset ButtonPower Button Reset Pin DefinitionsUSB 0/1 Chassis IntrusionUniversal Serial Bus USB USB 2/3 Chassis In trusionWake-On-LAN Pin Definitions Jwol Wake-On-LANWake-On-Ring Wake-on-Ring Pin DefinitionsSerial Ports Glan Giga-bit Ethernet PortsKB/Mouse Fan1 Fan6 Fan5 ATX PS/2 Keyboard and PS/2 Mouse PortsFan Headers Fan2 Fan3 Fan4VGA PWR Fault VGA ConnectorPower Fault Power Fail Pin Definitions PW4Speaker/Power LED Keylock ConnectorSMB Power I2 C Pin LocationsLAN1 Enable LAN2 Enable Jumper SettingsLAN1/LAN2 Enable/Disable Enable/Disable Jumper Settings JPL1, JPL2Cmos Clear Watch Dog Jumper Settings JWDWatch Dog Enable/Disable Jumper Settings JPG1 VGA Enable/DisablePCI slots to SMB VGA Enable PCI/PCIX slots to SMB Connection Jumper Settings J13, J15Scsi Enable Scsi Term. Enable Scsi Controller Enable/ Disable *ForX6DVA-4G onlyScsi Termination Enable/ Disable *ForX6DVA-4G only Scsi Enable/Disable Jumper Settings JPA1Alarm Reset PWR Force-On Alarm ResetPower Force-On Alarm Reset Jumper Settings JPR1Sata LED Header Onboard IndicatorsGlan LEDs Left Right Back ViewOn board LED Definitions Onboard LED Indicators DS1-DS5, DS7-DS8System LED DS9 System Alert LED DS9 DefinitionR a l l e l Port Parallel Printer Port ConnectorParallel Port, Floppy/Hard Disk Drive and Scsi Connections Parallel Printer Port Pin Definitions J10Floppy Connector Pin Definitions J24 Floppy ConnectorIDE Connectors IDE Connector Pin Definitions J44, J38Ultra320 Scsi Connector X6DVA-4G Only Pin Ultra320 Scsi ConnectorNo Power Troubleshooting ProceduresBefore Power On Or installing any hardware componentsMemory Errors Technical Support ProceduresLosing the System’s Setup Configuration Frequently Asked Questions Question How do I update my BIOS?Returning Merchandise for Service Question Whats on the CD that came with my motherboard?Starting Bios Setup Utility IntroductionMain Setup ProcessorsSystem Memory System Time/System DateConfigure Advanced CPU Settings Advanced SettingsXcpu Configuration Sub-Menu Ratio Cmos SettingAdjacent Cache Line Prefetch VRM Protection TemperatureHardware Prefetcher Hyper-Threading FunctionXide Configuration Sub-Menu Block Multi-Sector Transfer PIO ModeA.R.T. For Hard disk drives XFloppy Configuration XPCI/PnP Configuration IRQ3/IRQ4/IRQ5/IRQ7/IRQ9/IRQ10/IRQ11/IRQ14/IRQ15 Reserved Memory SizeXSuper IO Configuration Sub-Menu XAdvanced Chipset Settings PXH Channel A/Channel B Bus Frequency XIntel PCI-X Hub ConfigurationRAS Sticky Error Handling Port decodeXapci Configuration XPower ConfigurationXmps Configuration XEvent Log ConfigurationPCI/PCI Express Error Logging View Event LogXRemote Access Configuration Xpci Express ConfigurationRemote Access Xusb Configuration XSystem Health MonitorFan Speed Control Modules Boot SettingsFan1 Speed to Fan6 Speed Xbios Settings Configuration Interrupt 19 CaptureXRemovable Drives XBoot Device PriorityXHard Disk Drives XCD/DVD DrivesChange User Password Security SettingsChange Supervisor Password Clear User PasswordDiscarding Changes and Exit Exit OptionsDiscarding Changes Load Optimal Defaults Load Fail-Safe DefaultsX6DVA-4G/X6DVA-EG User’s Manual Amibios Error Beep Codes Beep Code Error Message DescriptionLED Indicators Description/Message DS7/DS8 LED Post CodesUncompressed Initialization Codes Checkpoint Code DescriptionBootblock Recovery Codes Video ROM has returned control to Bios POST. Performing any Monochrome mode and color mode settings next 48h Programming after Winbios Setup has completed. Displaying Completed programming DMA controllers 1 and 2. Initializing95h X6DVA-4G/X6DVA-EG User’s Manual Introduction to the Intel 6300 ESB I/O Controller Hub Page Using the Adaptec RAID Configuration Utility ARC Using the Array Configuration Utility ACUManaging Arrays Deleting Arrays From the ARC menu, select Array Configuration Utility ACUViewing Array Properties RAID 1 only-the following prompt is also displayedCreating Arrays To create an arrayAssigning Array Properties Raid Level Create Via When Appropriate When you are finished, press Done as the screen shown below Adding a Bootable Array Deleting a Bootable ArrayAdding/Deleting Hotspares Initializing Disk Drives To initialize drivesPage Page Rebuilding Arrays To Rebuild an arrayUsing the Disk Utilities To access the disk utilitiesPage To Exit Adaptec RAID Configuration Utility You can choose from the following optionsInstalling Intels 6300 ESB Driver by Adaptec and the OS Installing Other Software Programs and Drivers Onboard Scsi Users GuideSupero Doctor Supero Doctor III Interface Display Screen-II Remote Control

X6DVA-EG, X6DVA-4G specifications

American Megatrends is renowned for its innovative server and motherboard solutions. The X6DVA-4G and X6DVA-EG motherboards are notable examples that cater to enterprise-level applications and high-performance computing environments. Both motherboards are designed to support the latest advancements in technology while providing robust features for reliable performance.

The X6DVA-4G is an ATX motherboard that boasts dual Socket 604 configurations, allowing it to support dual Intel Xeon processors. This dual-processor setup significantly enhances computing power, making it suitable for resource-intensive applications, such as virtualization, high-performance computing, and database management. Its support for up to 64GB of DDR2 ECC memory ensures data integrity and stability during critical operations, providing an additional layer of reliability that is crucial for enterprise environments.

On the other hand, the X6DVA-EG offers similar capabilities while integrating different feature sets that cater to specific needs. Both boards support PCI-X and PCIe expansion slots, which allow for flexible hardware configurations. This expandability is vital in businesses where evolving technology demands can lead to the need for additional peripherals and components.

A standout feature of these motherboards is their comprehensive support for RAID configurations, including RAID 0, 1, 10, and 5. This functionality enhances data security and recovery, ensuring that critical information remains intact in the event of hardware failure. Additionally, both motherboards come equipped with multiple SATA interfaces for robust storage options, which are essential for handling large volumes of data.

Furthermore, Intel's Xeon processors, paired with the X6DVA series motherboards, enable advanced thermal management and power efficiency features. This is essential not only for maintaining optimal performance but also for reducing operational costs in data centers.

In conclusion, American Megatrends' X6DVA-4G and X6DVA-EG motherboards maintain the company's reputation for quality and reliability in high-performance computing solutions. With their dual-processor capabilities, extensive memory support, RAID functionality, and flexibility for expansion, these motherboards are exceptional choices for businesses looking to enhance their computing infrastructure. Their combination of performance, efficiency, and reliability makes them integral components for modern server solutions.