American Megatrends Ultra320 Scsi Connector X6DVA-4G Only, Pin Ultra320 Scsi Connector

Page 48

X6DVA-4G/X6DVA-EG User's Manual

Ultra320 SCSI Connector

(*X6DVA-4G Only)

Refer to the table below for the

pin definitions of the Ultra320

SCSI connector located at J28.

68-pin Ultra320 SCSI Connector

(*Note: Please refer to Appendix C for software, SATA Host RAID Utility, and the Operating System Installation Instructions.)

Connector

 

Contact

 

Number

Signal Names

1

+DB(12)

2

+DB(13)

3

+DB(14)

4

+DB(15)

5

+DB(P1)

6

+DB(0)

7

+DB(1)

8

+DB(2)

9

+DB(3)

10

+DB(4)

11

+DB(5)

12

+DB(6)

13

+DB(7)

14

+DB(P)

15

GROUND

16

DIFFSENS

17

TERMPWR

18

TERMPWR

19

RESERVED

20

GROUND

21

+ATN

22

GROUND

23

+BSY

24

+ACK

25

+RST

26

+MSG

27

+SEL

28

+C/D

29

+REQ

30

+I/O

31

+DB(8)

32

+DB(9)

33

+DB(10)

34

+DB(11)

 

 

Connector

 

Contact

 

Number

Signal Names

35-DB(12)

36-DB(13)

37-DB(14)

38-DB(15)

39-DB(P1)

40-DB(0)

41-DB(1)

42-DB(2)

43-DB(3)

44-DB(4)

45-DB(5)

46-DB(6)

47-DB(7)

48-DB(P)

49GROUND

50GROUND

51TERMPWR

52TERMPWR

53RESERVED

54GROUND

55-ATN

56GROUND

57-BSY

58-ACK

59-RST

60-MSG

61-SEL

62-C/D

63-REQ

64-I/O

65-DB(8)

66-DB(9)

67-DB(10)

68-DB(11)

 

SMB

PW3

24-Pin

ATX

 

 

 

 

 

Fan1

 

 

KB/

PWR

 

PWR1

PW1

 

 

 

 

 

 

Mouse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J2

Alarm

 

DS1

8-pin

PW2

 

 

 

 

 

 

 

 

Reset JPR1

CPU

PWR2

 

 

 

 

 

 

USB0/1

PWR

 

 

 

 

 

 

 

 

CPU1 VRM

 

 

PW4

PW LED

JPF

PWR Force On

 

 

 

J3

Fault

 

 

 

 

 

 

 

 

OHLED DS4

 

 

J4

 

 

 

 

DIMM 1B

 

J23

 

 

CPU 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1

 

 

 

 

DIMM 1A

 

J22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 2B

 

J21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 2A

 

J20

 

 

 

VGA

 

 

 

 

DIMM 3B

 

J19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

 

 

 

DIMM 3A

 

J18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU 2

GLAN1

 

 

 

 

 

 

Battery

MCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E7320

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN2

 

 

 

 

 

PXH

 

 

 

 

(Lindenhurst

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-VS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(PCI-E/

 

 

 

 

North

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN

 

 

PCIX

 

 

 

 

Bridge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTLR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPL1

 

SUPER

®

X6DVA-4G

 

 

 

 

 

 

 

 

 

 

LAN1Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8B1

64- bit PCIX #6 (PCIX-133)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JWD

 

 

 

 

CTLR

 

 

J9B1

64- bit PCIX

#5 (PCIX-100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WD

 

 

 

 

 

 

 

 

PCIX slots/

 

J15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPL2

 

 

 

 

 

 

JPA1(*SCSI Enable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMB Connect

J13

 

 

 

 

 

 

 

 

 

 

PWLED/ J41

 

IPMI

 

 

LAN2Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

JF2

 

 

 

 

 

 

 

 

 

 

 

 

X4 PCI-Epxess

 

 

 

 

 

 

 

 

 

 

SPKR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCI-E#4 J14

 

 

 

 

 

 

 

 

 

6300ESB

 

Fan6 Fan5

 

 

 

 

 

 

 

 

 

SCSI (LSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53C20)

 

Speaker

 

 

 

 

ICH

 

 

BIOS

 

 

 

 

 

VGA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTLR

WOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOR

 

 

 

JWOL

 

 

 

 

 

 

 

 

 

 

 

 

 

Clr CMOS

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI LED

DS3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPG1

VGA Enable

 

 

 

 

 

Cha. Intru

 

 

SI/O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

JA1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JL1

 

JSLED

 

 

 

 

 

 

 

 

 

32- bit PCI #1

 

 

J17

 

 

ChannelTerm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

SATA0 JS0 SATA1 JS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM2

 

Printer

 

J10

Floppy

 

J24

 

SCSI

 

 

 

J28

IDE 2

 

 

 

 

 

 

 

J5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan2

CPU2 VRM

Fan3

OH LED

DS2

L

 

 

 

 

R

 

 

 

 

T

PWR LED

DS5

C

P

 

 

 

 

F

 

 

 

 

JF1

System LED

DS9

 

 

 

 

 

 

USB2,3

 

 

 

 

 

 

 

 

 

 

POST

LED

1

 

 

 

E

 

JBT1

 

 

 

 

 

ID

 

 

DS8

 

DS7

 

 

 

 

 

 

 

 

 

SATA

 

 

 

 

 

LED

 

 

 

 

J44

 

J38

 

 

 

 

Fan4

 

 

 

 

 

 

 

 

 

SCSI

2-28

Image 48
Contents Super Page About This Manual Manual OrganizationTable of Contents Advanced Setup Boot Setup AppendicesIntroduction Page Checklist OverviewContacting Supermicro HeadquartersEurope Asia-PacificSuper X6DVA-4G/X6DVA-EG Image Super X6DVA-4G Jumper Description Default Setting Connector DescriptionQuick Reference X6DVA-4G/X6DVA-EG Please refer to for pin definitionsMotherboard Features M o r yChipset Expansion SlotsAcpi Features DimensionsOnboard I/O OtherBlock Diagram of the E7320 Lindenhurst-VS Chipset 6300ESB ICH System Features Chipset OverviewSpecial Features Recovery from AC Power LossEnvironmental Temperature Control PC Health MonitoringAcpi Features Auto-Switching Voltage Regulator for the CPU CoreCPU Overheat LED and Control TM2/CPU VRM OverheatSlow Blinking LED for Suspend-State Indicator Main Switch Override MechanismMicrosoft OnNow External Modem Ring-On WORPower Supply Super I/OWake-On-LAN WOL Page Precautions Static-Sensitive DevicesUnpacking PGA Processor and Heatsink Installation Installing the CPU Mounting Plate and Retention BracketCPU Installation CPU Mounting PlateHeatsink Installation To Un-install the HeatsinkHandle with care PGA604 Socket Empty and with Processor Installed Installing DIMMs Dimm Installation See FigureMounting the Motherboard in the Chassis Memory SupportI/OPorts/Control Panel Connectors I/O Port Locations and DefinitionsJF1 Header Pins Front Control PanelConnecting Cables ATX Power ConnectorProcessor Power Connector Power LED NMI ButtonNMI Button Pin Definitions Pwrled Pin DefinitionsNIC1/NIC2 LED Indicators HDD LED Pin DefinitionsNIC1 LED Pin NIC2 LED Pin Definitions Power Fail LED Overheat/Fan Fail LEDHealth LED PWR Fail LED Reset Button Power ButtonReset PWR Button Reset Pin DefinitionsChassis Intrusion Universal Serial Bus USBUSB 0/1 USB 2/3 Chassis In trusionWake-On-LAN Wake-On-RingWake-On-LAN Pin Definitions Jwol Wake-on-Ring Pin DefinitionsSerial Ports Glan Giga-bit Ethernet PortsATX PS/2 Keyboard and PS/2 Mouse Ports Fan HeadersKB/Mouse Fan1 Fan6 Fan5 Fan2 Fan3 Fan4VGA Connector Power FaultVGA PWR Fault Power Fail Pin Definitions PW4Connector SMB Power I2 CSpeaker/Power LED Keylock Pin LocationsJumper Settings LAN1/LAN2 Enable/DisableLAN1 Enable LAN2 Enable Enable/Disable Jumper Settings JPL1, JPL2Watch Dog Jumper Settings JWD Cmos ClearWatch Dog VGA Enable/Disable PCI slots to SMB VGA EnableEnable/Disable Jumper Settings JPG1 PCI/PCIX slots to SMB Connection Jumper Settings J13, J15Scsi Controller Enable/ Disable *ForX6DVA-4G only Scsi Termination Enable/ Disable *ForX6DVA-4G onlyScsi Enable Scsi Term. Enable Scsi Enable/Disable Jumper Settings JPA1Alarm Reset Power Force-OnAlarm Reset PWR Force-On Alarm Reset Jumper Settings JPR1Onboard Indicators Glan LEDsSata LED Header Left Right Back ViewOnboard LED Indicators DS1-DS5, DS7-DS8 System LED DS9On board LED Definitions System Alert LED DS9 DefinitionParallel Printer Port Connector Parallel Port, Floppy/Hard Disk Drive and Scsi ConnectionsR a l l e l Port Parallel Printer Port Pin Definitions J10Floppy Connector IDE ConnectorsFloppy Connector Pin Definitions J24 IDE Connector Pin Definitions J44, J38Ultra320 Scsi Connector X6DVA-4G Only Pin Ultra320 Scsi ConnectorTroubleshooting Procedures Before Power OnNo Power Or installing any hardware componentsTechnical Support Procedures Memory ErrorsLosing the System’s Setup Configuration Frequently Asked Questions Question How do I update my BIOS?Returning Merchandise for Service Question Whats on the CD that came with my motherboard?Starting Bios Setup Utility IntroductionMain Setup ProcessorsSystem Memory System Time/System DateAdvanced Settings Xcpu Configuration Sub-MenuConfigure Advanced CPU Settings Ratio Cmos SettingVRM Protection Temperature Hardware PrefetcherAdjacent Cache Line Prefetch Hyper-Threading FunctionXide Configuration Sub-Menu PIO Mode Block Multi-Sector TransferA.R.T. For Hard disk drives XFloppy Configuration XPCI/PnP Configuration IRQ3/IRQ4/IRQ5/IRQ7/IRQ9/IRQ10/IRQ11/IRQ14/IRQ15 Reserved Memory SizeXSuper IO Configuration Sub-Menu XAdvanced Chipset Settings XIntel PCI-X Hub Configuration RAS Sticky Error HandlingPXH Channel A/Channel B Bus Frequency Port decodeXapci Configuration XPower ConfigurationXEvent Log Configuration PCI/PCI Express Error LoggingXmps Configuration View Event LogXpci Express Configuration XRemote Access ConfigurationRemote Access Xusb Configuration XSystem Health MonitorBoot Settings Fan Speed Control ModulesFan1 Speed to Fan6 Speed Xbios Settings Configuration Interrupt 19 CaptureXBoot Device Priority XHard Disk DrivesXRemovable Drives XCD/DVD DrivesSecurity Settings Change Supervisor PasswordChange User Password Clear User PasswordExit Options Discarding Changes and ExitDiscarding Changes Load Optimal Defaults Load Fail-Safe DefaultsX6DVA-4G/X6DVA-EG User’s Manual Amibios Error Beep Codes Beep Code Error Message DescriptionLED Indicators Description/Message DS7/DS8 LED Post CodesUncompressed Initialization Codes Checkpoint Code DescriptionBootblock Recovery Codes Video ROM has returned control to Bios POST. Performing any Monochrome mode and color mode settings next 48h Programming after Winbios Setup has completed. Displaying Completed programming DMA controllers 1 and 2. Initializing95h X6DVA-4G/X6DVA-EG User’s Manual Introduction to the Intel 6300 ESB I/O Controller Hub Page Using the Adaptec RAID Configuration Utility ARC Using the Array Configuration Utility ACUManaging Arrays From the ARC menu, select Array Configuration Utility ACU Viewing Array PropertiesDeleting Arrays RAID 1 only-the following prompt is also displayedCreating Arrays To create an arrayAssigning Array Properties Raid Level Create Via When Appropriate When you are finished, press Done as the screen shown below Adding a Bootable Array Deleting a Bootable ArrayAdding/Deleting Hotspares Initializing Disk Drives To initialize drivesPage Page Rebuilding Arrays To Rebuild an arrayUsing the Disk Utilities To access the disk utilitiesPage To Exit Adaptec RAID Configuration Utility You can choose from the following optionsInstalling Intels 6300 ESB Driver by Adaptec and the OS Installing Other Software Programs and Drivers Onboard Scsi Users GuideSupero Doctor Supero Doctor III Interface Display Screen-II Remote Control

X6DVA-EG, X6DVA-4G specifications

American Megatrends is renowned for its innovative server and motherboard solutions. The X6DVA-4G and X6DVA-EG motherboards are notable examples that cater to enterprise-level applications and high-performance computing environments. Both motherboards are designed to support the latest advancements in technology while providing robust features for reliable performance.

The X6DVA-4G is an ATX motherboard that boasts dual Socket 604 configurations, allowing it to support dual Intel Xeon processors. This dual-processor setup significantly enhances computing power, making it suitable for resource-intensive applications, such as virtualization, high-performance computing, and database management. Its support for up to 64GB of DDR2 ECC memory ensures data integrity and stability during critical operations, providing an additional layer of reliability that is crucial for enterprise environments.

On the other hand, the X6DVA-EG offers similar capabilities while integrating different feature sets that cater to specific needs. Both boards support PCI-X and PCIe expansion slots, which allow for flexible hardware configurations. This expandability is vital in businesses where evolving technology demands can lead to the need for additional peripherals and components.

A standout feature of these motherboards is their comprehensive support for RAID configurations, including RAID 0, 1, 10, and 5. This functionality enhances data security and recovery, ensuring that critical information remains intact in the event of hardware failure. Additionally, both motherboards come equipped with multiple SATA interfaces for robust storage options, which are essential for handling large volumes of data.

Furthermore, Intel's Xeon processors, paired with the X6DVA series motherboards, enable advanced thermal management and power efficiency features. This is essential not only for maintaining optimal performance but also for reducing operational costs in data centers.

In conclusion, American Megatrends' X6DVA-4G and X6DVA-EG motherboards maintain the company's reputation for quality and reliability in high-performance computing solutions. With their dual-processor capabilities, extensive memory support, RAID functionality, and flexibility for expansion, these motherboards are exceptional choices for businesses looking to enhance their computing infrastructure. Their combination of performance, efficiency, and reliability makes them integral components for modern server solutions.