AMCC PN 720-0104-00 manual Unit Write Cache, Unit Policies

Page 30

3ware Disk Manager (3DM 2)

For additional information, see“Setting Background Task Rate” on page 113.

Unit Write Cache

You can enable or disable write cache for each unit.3DM lists each unit on the controller specified in the drop-down list on the menu bar, and shows you whether the write cache is currently enabled or disabled for it.

Write cache is a combination of the physical hard drives’ write cache as well as the controller’s memory, depending on what type of unit you are using.

For 9000-series controllers, a Disable Write Cache on Unit Degrade setting can be set in 3ware BIOS Manager (3BM). You can see if this setting is enabled in the Other Controller Settings field at the bottom of this Controller Settings page. If Disable Write Cache on Unit Degrade is enabled, upon degrade of a unit, the write cache will automatically be disabled, even if you enable write cache in the Unit Write Cache field.

For additional information, see “Enabling and Disabling the Unit Write Cache” on page 89.

Unit Policies

For units on 9000-series controllers, you can enable or disable two policies: Auto-verifyand Continue on Source Error During Rebuild. 3DM lists each unit on the controller specified in the drop-down list on the menu bar, and shows you whether the policies are currently enabled or disabled for each unit.

This section does not appear for 7000- and 8000- series controllers.

Auto-verify.The Auto-verify policy causes verify tasks to be performed repeatedly during a scheduled verify window. When Auto-verify is disabled, verify is not initiated automatically by the controller. Verify can still be started manually with 3DM, 3BM, or CLI. Once a manually-started verification is complete, no further verify tasks for the unit is performed.

Continue on Source Error During Rebuild. This policy applies only to units which are redundant. (For units which are not redundant, a check box is not available.) When this policy is set, ECC errors are ignored when they are encountered during a rebuild. When this policy is not set, a rebuild will abort upon encountering an ECC error and the unit will be set back to Degraded.

Since this option could result in the loss of some source data in the event of source errors, select this option only if you want to ensure that a rebuild will complete successfully without manually intervention. If the rebuild fails and Continue on Source Error During Rebuild is not selected, then you have the option to start a rebuild manually. It is recommended that a file system check be executed when the rebuild completes.

54

3ware 9000 Series Serial ATA RAID Controller User Guide

Image 30
Contents User Guide Supports the 9000 SeriesCopyright TrademarksDisclaimer 3ware Disk Manager 3DM Setting up Mozilla Browser Requirements for 3DMInstalling 3DM Installing 3DM on a Windows systemDM Remote Monitoring and Security Configuration Display DM E-mail Notification Preferences Uninstalling 3DM under Microsoft Windows Installing 3DM for Linux or FreeBSDDefault answer is no Uninstalling 3DM under Linux or FreeBSD Eject the CD-ROM disk when finishedStarting 3DM and Logging Starting 3DM under LinuxStarting 3DM under Windows Viewing 3DM Remotely via a Standard Web Browser LoggingWorking with the 3DM Screens DM Main Screen3DM Menus DM Menu Bar3DM Screens and What Theyre Used For Viewing Information About Different Controllers in 3DMRefreshing the Screen List of 3DM Pages3DM will use for listening Setting Up 3DM Preferences Setting and Changing 3DM PasswordsClick Save E-mail Settings Managing E-mail Event NotificationEnabling and Disabling Remote Access Setting the Incoming Port #Setting the Frequency of Page Refreshes Running Two Versions of 3DM 3DM 2 Reference Controller Summary3ware 9000 Series Serial ATA RAID Controller User Guide Controller Details Controller DetailsUnit Information Unit InformationUnit Details Unit Details3ware 9000 Series Serial ATA RAID Controller User Guide Drive Information Drive InformationSmart Details About Drive at Particular Port M.A.R.T DataController Settings Background Task RateUnit Write Cache Unit PoliciesOther Controller Settings Scheduling SchedulingAbout Task Schedules About Self-tests3ware 9000 Series Serial ATA RAID Controller User Guide Maintenance Rescan ControllerUnit Maintenance Maintenance Task Buttons 3ware 9000 Series Serial ATA RAID Controller User Guide For FreeBSD, the command would be Available Drives to Create Units Configuring a Unit in 3DM Alarms Alarms3DM 2 Reference 3DM Settings Mail NotificationPassword RefreshRemote Access Incoming Port #