Cortelco WPBX00 PRO MAN System Security Code, Distributor Password, Authentication Password

Page 2

WPBX00 PRO MAN

SYSTEM SECURITY CODE

The default System Security Code is ‘828828’.

To change the System Security Code:

(a)Enter Programming and select Setup-Set- tings-MBS-Change SSC.

(b)After selecting Change SSC, enter the new password (min of 1 number, max of 6 numbers) and confirm new password. Enter OK to ac- cept or CANCEL to exit the window and can- cel the new password. The password may be changed again before exiting the programming software without entering the new password.

(c)Once this password is changed, the pro- gramming can only be accessed by the new password or universal password which is ‘288288’.

(d)The MBS will allow 3 attempts to enter the correct SSC password before closing the pro- gramming.

DISTRIBUTOR PASSWORD

The default Distributor Password is ‘288288’. The Distributor Password cannot be changed.

AUTHENTICATION PASSWORD

The default Authentication Password is ‘12345678’. To change the Authentication Password:

(a)Enter Programming and select Setup-Set- tings-MBS-Change AC.

(b)After selecting Change AC, enter the new password (min 1 number, max 8 numbers) and confirm new password. Enter OK to accept the change or press CANCEL to exit the window and cancel the new password.

(c)The universal password does not ap- Page 2

ply to the Authentication code. The entire password must be reset. Refer to section 4.48.

GENERAL RULE

2.05When viewing any programming screens, the shaded items are informative items and cannot be changed. The white items are changeable items. In all screens, OK will accept the change and CANCEL will exit the window.

3.SOFTWARE INSTALLATION

3.01Programming of the Compass can be done through the PC using a RS232 interface. The software is shipped with each system and should be copied to the PC local directory.

3.02Before initializing the software pro- gramming, connect the RS232 cable to the Master Base Station PC setup port and also to the COM port of the PC.

3.03Run the setup program by executing the file “PABXCFG.EXE”.

3.04Check to see what COM port is being used on the PC. If the correct COM port is not selected in the programming, then select the correct port and press OK to start the connec- tion process again. When the COM port is correct, the MBS version is then displayed.

3.05Compass PC setup software port set- tings default to COM 1 at a baud rate of 19200 bps. Compass software port settings must match PC COM port settings. To change settings, find the file named pbx-set.ini and modify the port settings to 9600 bps (needed for MBS).

Image 2
Contents Cortelco System Security Code Distributor PasswordAuthentication Password MBS Communication Test Programming PC SetupRemote Connection TingsPBX Configuration Security CodeExtension Setup Member of a Group Change User NamePhone Book Call Forwarding Handset Deregistration Show Status Call LOG View Call LOG Save Call LOG PrintCall LOG Setup Number Plan Printer and page Setup Voice Mail Settings Pstn Line Settings Settings Autodial PrefixPause Time Settings Route to Auto AttendantDialing Mode Checks Dial Tone Detect and Flash ChoiceMBS Register Button MBS Pstn Conferencing MBS External Music on HoldMBS System Date and Time MBS Call Forward no Reply TimeMBS Call Pickup MBS Authenticaton Code AC MBS Change System Security Code SSCOperator Class of Service Class of Service DAY/NIGHT Mode Partially Clear Settings Eeprom Uploader Record MessageEeprom Downloader Configure Auto Attendant Auto Attendant Guide Recording Voice PromptPermanant Auto Attendant Mode No Digit TimeoutConsole and Auto Attendant Mode No Answer Greeting