INSTALLATION PLACEMENT

The MBK-E series is intended to be install in a temperature controlled environ- ment that is free of conductive contaminants. Select a location which will pro- vide good air circulation for the UPS at all times. Avoid locations near heating devices, water or excessive humidity, or where the UPS is exposed to direct sunlight. Route power cords so they cannot be walked on or damaged.

Operating Temperature (Maximum): 0 to 40 degrees C (+32 to 104 degrees F)

Operating Elevation: 0 to 3,000m (0 to 10,000 ft)

Operating and Storage Relative Humidity: 95%, non-condensing

Storage Temperature: -15 to +45 degrees C (+5 to +113 degrees F)

Storage Elevation: 0 to 15,000m (0 to +50,000 ft)

INSTALLATION

Be sure to read the installation placement and all the cautions before installing the UPS. Place the UPS in the final desired location and complete the rest of the installation procedure. USE CAUTION: The UPS is heavy. Use the appropriate number of personnel when installing the UPS.

CONNECTING YOUR EQUIPMENT

Plug the equipment into the output receptacles on the rear panel of the UPS. Do not use extension cords, adapter plugs, power strips or surge strips on the output of the UPS. Ensure that you do not exceed the maximum output rating of the UPS (refer to the UPS's back panel or the Electrical Specifications in this manual).

CAUTION! DO NOT connect a laser printer to the output receptacles on the UPS, unless the UPS is rated 2000VA or greater. A laser printer draws significantly more power when printing than at idle and

may overload the UPS.

7

Image 8
Contents MBK-E Series English Important Safety Instructions Authorized Service Personnel only Receiving Inspection English Rear Panel Connecting Your Equipment Installation PlacementInstallation Connecting the UPS to AN AC Source Checking the Site Wiring FaultCharging the Battery Communications Port Connection OptionalSelf Test DIP Switch SettingsTurning the Unit ON/OFF Alarms On Battery LOW Battery WarningWEAK/BAD Battery UPS FaultSymptom Possible Cause What To Do Replacing the Battery Authorized Service Personnel onlyBattery Replacement Procedure English If the UPS Requires Service Minuteman UPSEnglish UPS ID MBK-E English Limited Product Warranty Robert Calhoun Declaration of ConformityEnglish English Do not print PN 34000227 Rev

MBK-E SERIES specifications

The Minuteman UPS MBK-E Series is engineered for the demanding environments of today’s digital world, providing reliable power protection for sensitive electronic systems. This series is particularly suited for applications in data centers, manufacturing facilities, and telecommunications, where downtime can result in significant financial loss.

One of the standout features of the MBK-E Series is its true online double conversion technology. This advanced technology ensures that connected equipment receives a consistent and clean power supply, free from disturbances such as voltage spikes, sags, and electrical noise. The UPS operates continuously, converting incoming AC power into DC power and then back to AC power, which results in a stable output, even during abnormal input conditions.

The MBK-E Series also includes a wide input voltage range, allowing the UPS to maintain operational capabilities even in fluctuating power environments. This feature is particularly valuable in regions with unreliable power infrastructure. Furthermore, the product is equipped with an advanced battery management system that extends battery life through intelligent charging methods, ensuring that critical systems remain powered during outages.

One of the notable characteristics of the MBK-E Series is its modular design. With an easily expandable capacity, users can customize their UPS systems to meet their specific needs, enabling straightforward upgrades as power demands grow. This flexibility helps organizations efficiently manage their investment in power protection.

In addition to its robust performance features, the MBK-E Series includes comprehensive monitoring and management options. Users can access real-time data regarding power conditions, battery status, and overall system health through an intuitive LCD interface. Remote management capabilities, often facilitated through SNMP or USB interfaces, allow for proactive monitoring and alerts, minimizing the risk of system failures.

The Minuteman UPS MBK-E Series is also designed with energy efficiency in mind, incorporating features such as eco-mode operation to reduce power consumption while maintaining critical functions. By lowering environmental impact and operational costs, this UPS series supports both sustainability and financial efficiency.

Overall, the Minuteman UPS MBK-E Series stands out for its reliability, performance, and flexibility, making it an excellent choice for businesses looking to safeguard their electronic devices and infrastructure against power interruptions. It embodies a blend of cutting-edge technology and user-friendly features, providing peace of mind in today’s power-sensitive landscape.