LST BC216-2, BC216-3, BCE216-3LG manual Clear Concept

Page 2

Clear Concept

The BCnet Sectional Control Panel/Extension BCE216-3LG extends a BCnet sectional control panel BC216-2 or BC216-3, respectively, by two ADM loops. It provides the following features:

Detectors and modules in ADM loop technology can be connected to each Loop Interface LIF64-1. Depen- ding on the parameterisation, either the Apollo/Disco- very protocol or the System Sensor/200 protocol is used to achieve bi-directional data transfer.

Logical combinations of detectors and detector zo- nes for the activation of external controls and alar- ming devices facilitate maximum flexibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parame- terisation possibilities, individual requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.

By integrating input and output modules on any positi- on in the loop you can realize enablements or disable- ments as well as control tasks in your system without having to care for additional wires.

The free combination of detectors and modules into logic sectors allows for the joint operation of defi ned parts of the system even beyond the limits of loops or sectional control panels.

The use of unshielded loop cables allows for cost- saving and uncomplicated installation as well as for the possibility of reusing the existing cabling.

At a possible breakdown of the central processing unit which is integrated on the extension, the diver- sifi ed redundancy concept ensures secure alarm re- cognition.

The parameter data can be created by means of the PC software PARSOFT and loaded into the control pa- nel in a comfortable way. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.

AUTO setup facilitates parameterisation when the control panel is commissioned or expanded and thus helps to save time.

The BCnet Sectional Control Panel/Extension BCE216-3LG is suitable for later installation in the wall mount cabinet.

Owing to the compact design, a maximum of four loops can be centralized in one single place. The required bat- teries are accommodated in the wall mount cabinet or in an external auxiliary case. Series BC216 thus stands for modularity and easy expansion.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed by ISO 9001.