POWER AMPLIFIER
BALANCED INPUT WIRING TO WHARFEDALE PRO UNIT WITH XLR CONNECTORS
BALANCED OUTPUT |
| INPUT to Wharfedale Pro unit | ||
|
|
| SIGNAL DIRECTION | |
|
|
|
|
|
2 | 1 |
| 1 | 2 |
| Ground (earth) | CABLE | Only connect ground if hum occurs |
|
| 3 |
| 3 |
|
|
|
| ,, |
|
BALANCED INPUT WIRING TO WHARFEDALE PRO UNIT WITH 1/4 JACK to XLR CONNECTORS |
| |||
|
|
| INPUT to Wharfedale Pro unit | |
BALANCED OUTPUT | SIGNAL DIRECTION |
| ||
|
|
| ||
RING |
|
|
| |
TIP |
|
| 1 | 2 |
|
|
|
| |
| SLEEVE | CABLE | Only connect ground if hum occurs |
|
| Ground (earth) |
|
3
,,
BALANCED INPUT WIRING TO WHARFEDALE PRO UNIT WITH STEREO 1/4 JACK to XLR CONNECTORS
SIGNAL DIRECTION
BALANCED OUTPUT
INPUT to Wharfedale Pro unit
RING |
| SLEEVE | TIP |
|
| ||
|
|
| |
TIP |
| RING |
|
SLEEVE |
|
|
|
Ground (earth) | CABLE | Only connect ground if hum occurs |
|
,,
BALANCED INPUT WIRING TO WHARFEDALE PRO UNIT WITH XLR CONNECTORS to STEREO 1/4 JACK
BALANCED OUTPUT |
| INPUT to | |
|
| SIGNAL DIRECTION | |
|
|
| Wharfedale Pro unit |
|
|
| SLEEVE |
2 | 1 |
| TIP |
|
| ||
| Ground (earth) | CABLE | Only connect ground if hum occurs |
| 3 |
| RING |
|
|
|
,,
UNBALANCED INPUT AND OUTPUT WIRING WITH MONO 1/4 JACK CONNECTIONS
OUTPUT | SIGNAL DIRECTION | INPUT to Wharfedale Pro unit | |
OUTPUT Wharfedale Pro unit | SIGNAL DIRECTION | INPUT |
|
|
| SLEEVE | TIP |
|
|
| |
TIP |
|
|
|
SLEEVE |
|
|
|
Ground (earth) | CABLE |
|
|
A great deal of mistakes in sound installations can be down to wrongly wired audio connections. It is important that the connections are correct to suit your system.
Unbalanced system
An unbalanced audio system is typically a single conductor shielded with the centre conductor relaying the signal and the shield at ground.
Balanced system
Using a balanced audio system is where a two conductor shielded cable has each of the two centre conductors carrying the signal but of opposite phase. This gives each conductor an equal but inverted potential difference from that of the ground.
It is recommend that you use balanced audo connections if the unit before your amplifier has a balanced output. This will eliminate such as mains hum. For the best results xommon grounding should be avoided. This means not connecting the ground on both the amplifiers input and output connectors. Wharfedale pro advise that you connect the ground (shield) of the input connecting cable to the ground of the signal source while making sure the ground (shield) is not connected to the amplifier's input connector. The output cable connector from the amplifier if linking to another amplifier (daisy chained via parallel input sockets) should have the ground (shield) connected. The input connector ground (shield) to the following amplifier should not be connected. This is the process by which the ground (shield) is connected (tied) at the source unit but is not connect to the destination unit. If hum develops in some instances the ground (shield) can be connected on the input. Some manufacturers have units that recommend that the input connector ground (shield) is tied and the output disconnected. In this instance you may need to connect the input connector ground (shield) going to the input of the wharfedale pro unit. If an unbalanced system is used with XLR connections please connect pin 3 to pin 1 (ground) of the connector. This will mean that pin 2 transports the positive (+/hot) signal. If pin 3 to pin 1 are not connected this results in the negative
BALANCED OUTPUT WIRING FROM WHARFEDALE PRO UNIT WITH XLR CONNECTORS TO BALANCED UNIT
OUTPUT from Wharfedale Pro unit |
| BALANCED INPUT | ||
|
|
| SIGNAL DIRECTION | |
|
|
|
|
|
2 | 1 |
| 1 | 2 |
| Ground (earth) | CABLE | Only connect ground if hum occurs |
|
| 3 |
| 3 |
|
Please note that some manufacturers run their units with pin 2