Controller

Device responsible for polling terminals and routing

 

messages in a multipoint environment.

Control Signal

Subchannels contend for use of the main channel to

Contention Mode

send data to the CPU or controller. In the control

 

signal contention mode, subchannel devices contend

 

by raising control signal RTS if the device is a DTE,

 

or control signal DCD if the device is a DCE. The

 

2185 DSD returns CTS to a selected subchannel

 

device. The selected subchannel disconnects from

 

the main channel when the subchannel device drops

 

RTS or DCD.

DATA

LED indicator lamp that illuminates when the main

 

channel inbound data is aSPACE.

Data Contention

Subchannels contend for use of the main channel to

 

send data to the CPU or controller. In the data

 

contention mode, a subchannel contends for access

 

to the main channel by sending data (beginning with

 

a space bit). The selected subchannel disconnects

 

from the main channel after 16 consecutive mark

 

bits are detected.

Modem-Sharing

In the modem-sharing mode, the CPU or controller

 

is at a site remote from the 2185. The 2185's main

 

channel connects to the CPU through a modem link

 

(DCE). Subchannel terminals are connected

 

directly to the 2185 DSD.

Multipoint

A communications arrangement where multiple

 

devices share a common transmission channel,

 

though only one device may transmit at a time.

 

Such networks usually require some kind of polling

 

mechanism, which is under the control of a master

 

station, to ensure that only one device transmits data

 

at a time. Also known as a multidrop network.

Port

Physical point of access into a computer, a network,

 

or other electronic device.

Port-Sharing

In the port-sharing mode, the 2185's main channel is

 

connected directly to a CPU or controller port

 

(DTE). Subchannel devices communicate with the

 

2185 DSD via modem links.

Glossary-2

Image 58
Contents Telenetics Proprietary Material Page Page Contents Ordering Information Introduction FeaturesData Interface Main Channel Broadcast Subchannel ContentionSynchronous Data Retiming Buffer Applications Anti-StreamingPort-Sharing Mode Port-Sharing ApplicationModem-Sharing Mode Modem-Sharing ApplicationCo-Located Terminals CascadingLocal Cascading Application Remote Cascading Application Specifications SpecificationsTelenetics Customer Responsibilities Site Selection and PreparationEquipment Supplied UnpackingPacking Materials Damage/Material ShortagesInstallation Tools Required Installation ProcedureEquipment Assembly Mechanical InstallationRear Panel Assembly Straight-Through Cable Interface Telenetics Operating Controls Indicators Front View Door ClosedInside Front Panel Function Switch One Function SwitchesEnabling/Disabling Subchannels Data Rate Selection Using Switch Segments 1-6 to Function Switch TwoFunction Switch Two Summary Switch Segment 2-1 Contention Mode Switch Segment 2-4 Anti-Streaming Enable/Disable Clock Routing ConfigurationsSwitch Segment 2-7 Main Channel RTS/DCD Strapping External Clock Reference with Main Channel DTE External Clock Reference with Main Channel DCE Internal Clock Reference with Main Channel DTE Internal Clock Reference with Main Channel DCE Subchannel 1 DCE Clock Reference with Main Channel DTE Subchannel 1 DCE Clock Reference with Main Channel DCE Function Switch Three LED IndicatorsConfiguration Examples DTE/DCE OptioningDigital Bridging Application Example Digital Bridging Application Switch One Switch TwoLeased-Line Backup Application Example Switch Three10 Leased-Line Backup Application Switch One 10. Switch Two 11. Switch ThreeMultimaster Multidrop Application Example 11. Multimaster Multidrop Application12. Switch One Settings 2185 a 14. Switch Three Settings 2185 a 13. Switch Two Settings 2185 a15. Switch One Settings 2185 B 16. Switch Two Settings 2185 B 17. Switch Three Settings 2185 BMain Power Connection 18. LED Status Indicator Functions12 Power Connection POWER-DOWN Procedure OperationCorrective Maintenance Maintenance PhilosophyPreventive Maintenance Recovery from Anti-Streaming Alarm ConditionReturning Defective Equipment for Repair Installations in the USAGeneral Packing Information Installations Outside the USA or Canada Telenetics Ordering Information Telenetics Ordering InformationTelenetics Glossary Glossary-2 Glossary-3 Glossary-4 Index INDEX-2 INDEX-3 INDEX-4