Telenetics 2185 manual Switch Two, Switch Three

Page 43

 

 

Telenetics 2185

 

 

 

 

Table 3-10. Switch Two

 

 

 

 

 

 

Switch

 

 

 

Segment

Setting

 

Reason

 

 

 

 

2-1

Down

 

Data Contention

 

 

 

 

2-2

Up

 

Synchronous operation

 

 

 

 

2-3

Up

 

Retiming Buffer on

 

 

 

 

2-4

XX

 

Depends on line conditions

 

 

 

 

2-5

Down

 

Clock source from

 

 

 

 

2-6

Up

 

Subchannel One DSU

 

 

 

 

2-7

Down

 

RTS/DCD on all the time

 

 

 

 

2-8

XX

 

Doesn't matter (Main Ch DTE)

 

 

 

Table 3-11. Switch Three

 

 

 

 

Switch

 

 

 

Segment

Setting

 

Reason

 

 

 

 

3-1

Up

 

Main Channel connection to DTE

 

 

 

 

3-2

Down

 

Subchannel one connection to DCE

 

 

 

 

3-3

Down

 

Subchannel two connection to DCE

 

 

 

 

3-4

XX

 

Subchannel three not used

 

 

 

 

3-5

XX

 

Subchannel four not used

 

 

 

 

3-6

XX

 

Subchannel five not used

 

 

 

 

3-21

Image 43
Contents Telenetics Proprietary Material Page Page Contents Ordering Information Introduction FeaturesData Interface Main Channel Broadcast Subchannel ContentionSynchronous Data Retiming Buffer Anti-Streaming ApplicationsPort-Sharing Application Port-Sharing ModeModem-Sharing Application Modem-Sharing ModeCascading Co-Located TerminalsLocal Cascading Application Remote Cascading Application Specifications SpecificationsTelenetics Site Selection and Preparation Customer ResponsibilitiesDamage/Material Shortages UnpackingPacking Materials Equipment SuppliedMechanical Installation Installation ProcedureEquipment Assembly Installation Tools RequiredRear Panel Assembly Straight-Through Cable Interface Telenetics Front View Door Closed Operating Controls IndicatorsInside Front Panel Function Switch One Function SwitchesEnabling/Disabling Subchannels Data Rate Selection Using Switch Segments 1-6 to Function Switch TwoFunction Switch Two Summary Switch Segment 2-1 Contention Mode Clock Routing Configurations Switch Segment 2-4 Anti-Streaming Enable/DisableSwitch Segment 2-7 Main Channel RTS/DCD Strapping External Clock Reference with Main Channel DTE External Clock Reference with Main Channel DCE Internal Clock Reference with Main Channel DTE Internal Clock Reference with Main Channel DCE Subchannel 1 DCE Clock Reference with Main Channel DTE Subchannel 1 DCE Clock Reference with Main Channel DCE DTE/DCE Optioning LED IndicatorsConfiguration Examples Function Switch ThreeDigital Bridging Application Example Digital Bridging Application Switch Two Switch OneSwitch Three Leased-Line Backup Application Example10 Leased-Line Backup Application Switch One 11. Switch Three 10. Switch Two11. Multimaster Multidrop Application Multimaster Multidrop Application Example12. Switch One Settings 2185 a 14. Switch Three Settings 2185 a 13. Switch Two Settings 2185 a15. Switch One Settings 2185 B 17. Switch Three Settings 2185 B 16. Switch Two Settings 2185 B18. LED Status Indicator Functions Main Power Connection12 Power Connection Operation POWER-DOWN ProcedureRecovery from Anti-Streaming Alarm Condition Maintenance PhilosophyPreventive Maintenance Corrective MaintenanceReturning Defective Equipment for Repair Installations in the USAGeneral Packing Information Installations Outside the USA or Canada Telenetics Telenetics Ordering Information Ordering InformationTelenetics Glossary Glossary-2 Glossary-3 Glossary-4 Index INDEX-2 INDEX-3 INDEX-4