2.3.4 POWER CORD
1.Remove the control box. (Refer to section 2.1.3)
2.Open the control box. (Refer to section 2.3.3)
3.Disconnect the grounding screw from the control box.
4.Disconnect the 2 receptacles.
5.Remove a screw which fastens the clip cord. (See Figure 10)
6.Remove the power cord.
7.
(Use only one | for ground |
connection.) |
|
8.If the supply cord of this appliance is damaged, it must be replaced by the special cord. (The special cord means the cord which has the same specification marked on the supply cord attached at the unit.)
2.3.5 THERMOSTAT
1.Remove the control box. (Refer to section 2.1.3)
2.Open the control box. (Refer to section 2.3.3)
3.Remove the 2 screws which fasten the thermostat.
4.Disconnect 2 leads of thermostat terminals.
5.Remove the thermostat.
6.
2.3.6 ROTARY SWITCH
1.Remove the control box. (Refer to section 2.1.3)
2.Open the control box. (Refer to section 2.3.3)
3.Remove the 2 screws which fasten the rotary switch.
4.Disconnect all the leads of the rotary switch terminals.
5.Remove the rotary switch.
6.
2.3.7 MOTOR
1.Remove the cabinet. (Refer to section 2.1.2)
2.Remove the evaporator. (Refer to section 2.2.1)
3.Remove the orifice. (Refer to section 2.2.1)
4.Remove the blower. (Refer to section 2.2.1)
5.Remove the fan. (Refer to section 2.2.2)
6.Remove the control box cover and housing of the motor in the control box. (Refer to section 2.1.3)
7.Remove the 2 screws which fasten the motor from the mount motor. (See Figure 13)
8.Remove the motor.
9.
— 8—
Figure 10
Figure 11
Figure 12
Figure 13