Setting Control Across Groups
You can use cables to
To bus two or more groups’ NC signaling to one NC Port using Bus DIP switches:
•Groups must be contiguous (Group 3 to Group 2 to Group 1)
•The NC port you plan to use must be the
•The NMS Bus DIP switch between groups whose signals are to be bussed to a common NC port must have all six positions set to the low number (if all six positions are set to the high number,
Caution
Do not mix switch settings to high and low numbers. This causes interference with Network Control signaling.
Example
For example, to bus signals from group 2 to group 1’s NC port:
1)Ensure that Bus 1 Master slot is occupied. Other slots in groups 1 and 2 need not be (because the backplane uses a
2)On the backplane, locate the NMS Bus DIP switch between Bus 1 Master slot and Bus 2 Master slot (Figure 11). Set all six NMS Bus DIP switches to 1.
3)Connect the network management cable (supplied with your network manager) from the Bus 1 Master slot NC IN port to the network manager.