SIIG UM022_02 user manual Setting-up of Address

Page 9

4.2.1. Setting-up of ADDRESS

SW9

1.Unscrew two screws on bottom side of the keyboard and remove bottom cover.

2.Push switch SW9 on PCB bottom side; backlight LED’s are switched Off to indicate Set Address Mode.

3.Button LED’s indicate ADDRESS in binary code – Button 1 bit 0, Button 2 bit 1 etc… Push buttons to toggle address bits to requested value of ADDRESS (see examples on the picture below).

4.Push switch SW9 to save ADDRESS to non-volatile memory and to enter keyboard Standard Mode - backlight LED’s are switched On to indicate Standard Mode.

5.Assembly the control panel.

4.2.2. Troubleshooting

Flashing backlight LED’s means non-volatile memory ERROR. Try Power OFF – Power ON sequence to restart device and set ADDRESS again.

4.2.3. Display ADDRESS

Press and hold Button 1 while powering On. Button LED’s indicate ADDRESS in binary code – Button 1 bit 0, Button 2 bit 1, .... After 10 sec keyboard continues normal operation.

4.2.4. Display Firmware version

Press and hold Button 2 while powering ON. All LED’s flashes 5 times – FW version 1.05. After 10 sec keyboard continues normal operation.

User Manual Small Keyboards

www.cuesystem.com

Page 9 of 18

Image 9
Contents Small Keyboards Page Table of Contents Overview IntroductionFront Panel Button Labels Buttonledid Addressing289 296 Setting-up of Address Mounting Connecting Specifications and Mechanical Drawings Single buttons or 4 double buttons License Grant Software and Firmware LicenseWarranty Duration Warranty ConditionsCE Declaration of Conformity CE Declaration of ConformityFCC