PROBLEM | REASON | SOLUTION |
|
|
|
Inverter does not turn on. | Poor contact at terminals | Check for poor connection |
|
| to battery or power supply. |
|
| Make sure connection points |
|
| are clean. Rock clamps |
|
| back and forth for a better |
|
| connection. |
| Fuse is blown. | A blown fuse is usually |
|
| caused by reverse polarity |
|
| or a short circuit within the |
|
| inverter. |
|
| To replace, contact a qualified |
|
| service technician who will |
|
| diagnose the inverter and |
|
| replace the fuse(s) with the |
|
| appropriate replacement(s). |
| Inverter may be defective. | See warranty and call |
|
| Customer Service |
|
| 5485 (Hours 7:00 am to 5:00 |
|
| pm CST). |
|
|
|
10. SPECIFICATIONS
Model: XI41DU |
|
Maximum Continuous Output | |
Surge Capacity (0.1 second) | |
No Load Current Draw | <0.5A |
Output Wave Form | Modified Sine Wave |
Input Voltage Range | 10.5V – 15.5V DC |
Output Voltage Range | 120V ± 5% AC |
Low Battery Alarm | Audible, 11V ± 0.3V DC |
Low Voltage Shut Off | 10.5V ± 0.3V DC |
Over Voltage Shutdown | 15.5V ± 0.5V DC |
Optimum Efficiency | 85% |
AC Receptacle | Two, NEMA 5 - 15 USA |
USB Port | One, USB 5V 0.5 Amp |
Dimensions | 5” L x 4” W x 2.2” H |
Weight | approximately 2 lbs. |
• 9 •