PMP3000 Models
In Review
•Never attempt to operate the inverter from any other power source other than a
•When connecting and using the inverter, make sure that the inverter is positioned far away from any potential source of flammable fumes or gases.
•Make certain that the power consumption of the equipment you wish to operate is compatible with the capacity of the inverter. Do not exceed 3000 watts in total power, or 1600 watts for each individual AC outlet.
•When attempting to operate battery chargers, monitor the temperature of the battery charger for approximately 10 minutes. If the battery charger becomes abnormally warm, disconnect it from the inverter immediately.
•Use only 30 amp spade type fuses for the inverter.
•When operating the inverter with an automobile or marine battery, start the engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the battery.
•In the event of a continuous audible alarm or an automatic shut down of the unit, turn the inverter OFF immediately. Do not turn the inverter ON again until the source of the problem has been identified and corrected.
•To avoid battery drain, always disconnect the inverter when not in use.
•Do not expose the inverter to rain or moisture.
•Avoid placing the inverter near sources of heat or in direct sunlight.
•While in use, make sure that the inverter is properly ventilated.
•For best operating results, make sure the unit is placed on a flat surface.
|
|
| Owner’s Manual |
|
|
|
|
Troubleshooting |
| ||
PROBLEM: Low or No Output Voltage |
| ||
|
| Reason | Solution |
|
|
|
|
|
| Poor contact with | Clean terminals |
|
| ||
|
| battery terminals. | thoroughly. Reattach |
|
| ||
|
| ||
|
|
| battery clips. |
|
|
|
|
|
| Using incorrect type of | Use true RMS reading meter. |
|
| ||
|
| voltmeter to test |
|
|
|
| |
|
|
| |
|
| output voltage. |
|
|
| ||
PROBLEM: Red LED On |
| ||
|
| Reason | Solution |
|
|
|
|
|
| Battery voltage below | Recharge or replace battery. |
|
| 10.0 ± 0.5 volts. |
|
|
|
| |
|
|
| |
|
|
|
|
|
| Equipment being operated | Use a higher capacity inverter |
|
| ||
|
| draws too much power. | or do not use this equipment. |
|
| ||
|
|
|
|
|
| Inverter is too hot (thermal | Allow inverter to cool. |
|
| ||
|
| shutdown mode). | Check for adequate ventilation. |
|
| ||
|
|
| Reduce the load on the |
|
|
| inverter to rated continuous |
|
|
| power output |
|
|
|
|
|
| Unit may be defective. | See Warranty and call |
|
| ||
|
|
| Customer service at |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
7 | 8 |