6.0: REVEAL 66 TECHNICAL SPECIFICATIONS

LOUDSPEAKER

Frequency response (1)

57Hz – 51kHz

 

 

Recommended amplifier power

80 to 150 W rms into 8

 

 

Power handling

Average (2) 80W rms

 

Programme 160W

 

 

Nominal Impedance

6

 

 

Sensitivity SPL / 1 W @ 1 m (3)

92dB

 

 

Distortion

< 0.6%

 

 

Crossover frequency

2.7kHz

 

 

Dispersion (@ -6dB)

90 degrees

 

 

Drive unit LF/MID

200mm (8") multi fibre paper pulp cone

 

 

WideBand™ HF

25mm (1") titanium dome neodymium magnet system

 

 

Shielded

Yes

 

 

 

 

CABINET

 

 

 

Low frequency design

Optimised bass-reflex loaded

 

 

Cabinet construction

MDF cabinet and front baffle, Tongue and groove front and back

 

 

Cabinet finish

Maroon satin texture finish front, Grey vinyl sides and back

 

 

Fittings

4 x M6 inserts for Omnimount™ 30 series bracketry

 

 

Cabinet dimensions (HxWxD)

230mm (9”) x 527mm (203/4”) x 340mm (133/8”)

 

 

Total Cabinet weight

12.8kg (28.16lbs)

 

 

 

 

NOTES

(1)/- 3 dB, measured at 1m in an anechoic chamber. (2) Long term power handling capacity as defined in EIA standard RS426A.

(3)Averaged over specified bandwidth for half-space environment.

Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserve the right to alter without prior notice. Please verify the latest specifications when dealing with critical applications.

7.0: SERVICING 7.1: CABINET FINISH

To remove marks and scuffs use a soft brush. If necessary, a little warm water and detergent can be used but under no circumstances use a solvent or abrasive cleaner.

7.2: DRIVER REMOVAL

Lay the cabinet on its back. Remove the ten hexagonal screws and set aside. Ease the driver from the front of the cabinet taking care not to mark the front surface. Remove the driver, note the polarity of the internal connections and disconnect the internal wiring. Take care not to damage the moving parts of the LF driver. To refit the driver, connect the cables from the crossover to the LF terminals. Fit the driver into the mounting hole, making sure that the internal connecting cables are not trapped or able to touch the LF cone. Fasten the screws finger tight and then progressively tighten them down with the appropriate Allen key. Repeat the same procedure for the HF driver.

7.3: CROSSOVER

The crossover is mounted on the rear of the terminal panel. To inspect it, remove the panel by releasing the hexagonal screws. Take care to avoid undue stress on the cables and components.

To remove the crossover completely the cables must be disconnected from the drive unit. Please proceed as above to remove the drive unit.

18

7.4: LIST OF SPARE PARTS

PART NUMBER

 

DESCRIPTION

 

 

 

Type 1603

-7900 0747

Driver Kit

 

 

 

 

Type 0294

– 7900

0891B

High Frequency Unit

 

 

 

 

Type 1465

– 7300

0938

Passive Crossover

 

 

 

 

Further spare part details and factory part numbers can be found at www.tannoy.com

8.0: WARRANTY

NO MAINTENANCE OF THE REVEAL 66 MONITOR IS NECESSARY.

All components are guaranteed for a period of five years from the date of manufacture, subject to the absence of, or evidence of, misuse, overload or accidental damage.

For further information please contact your dealer or the distributor in your country.

If you cannot locate your distributor please contact:

Customer Services, Tannoy Ltd., Coatbridge, Strathclyde, ML5 4TF, Scotland

Telephone: 01236 420199 (UK) +44 1236 420199 (International)

Fax: 01236 428230 (UK) +44 1236 428230 (International)

Internet: http://www.tannoy.com

DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION

This warranty in no way affects your statutory rights.

9.0: DECLARATION OF CONFORMITY

The following apparatus is/are manufactured in China for Tannoy Ltd of Rosehall Industrial estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended.

This equipment conforms to the requirements of the EMC Directive 89/336/EEC, amended by 92/31/EEC and 93/68/EEC and the requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC.

Details of the Apparatus:

Tannoy Monitor Loudspeaker

Model Number:

Reveal 66

Applicable Standards:

EN55103-1:1996 Emission

 

EN55103-2:1996 Immunity

 

Electrical Safety EN60065:1993

Signed:

 

Position:

Technical Director

Date:

1 March 2005

For Tannoy Ltd

 

19

Image 10
Contents Passive Studio Monitors Contents Placement of the Speakers Power AmplifiersOrientation Positioning Console ReflectionsSpeaker Mounting Reveal 6 DimensionsBass Ports Servicing 7.1 Cabinet Finish Reveal 6 Performance Data Reveal 6 Technical SpecificationsDriver Removal List of Spare Parts WarrantyCrossover Declaration of ConformityIntroduction 5.1 Surround Monitoring Installing and PositioningReveal 66 Dimensions EqualisationReveal 66 Technical Specifications No Maintenance of the Reveal 66 Monitor is Necessary