Tanita BC-554 Preparations Before USE, Getting Accurate Readings, Automatic SHUT-DOWN Function

Page 3

GB

PREPARATIONS BEFORE USE

Inserting the Batteries

Open the battery cover on the back of the measuring platform. Insert the supplied AA-batteries as indicated.

Note: Be sure that the polarity of the batteries is set properly. If the batteries are

incorrectly positioned the fluid may leak and damage floors. If you do not intend to use this unit for a long period of time, it is advisable to remove the batteries before storage.

Please note that the included batteries from factory may have decreased energy levels over time.

Positioning the Monitor

Place the measuring platform on a hard, flat surface where there is minimal vibration to ensure safe and accurate measurement.

Note: To avoid possible injury, do not step on the edge of the platform.

Handling Tips

This monitor is a precision instrument utilizing state-of-the-art technology. To keep the unit in the best condition, follow these instructions carefully: Do not attempt to disassemble the measuring platform.

Store the unit horizontally, and place it so that the buttons will not be pressed accidentally. Avoid excessive impact or vibration to the unit.

Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.

Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny; avoid soaps.

Do not step on the platform when wet.

Do not drop any objects onto the platform.

GETTING ACCURATE READINGS

GB

SWITCHING THE WEIGHT MODE Note: For use only with models containing the weight mode switch

You can switch the unit indication by using the switch on the back of the scale as shown in the figure.

Note: If weight mode is set to pounds or stone-pounds, the height programming mode will be automatically set to feet and inches. Similarly, if kilograms is selected, height will be automatically set to centimetres.

SETTING AND STORING PERSONAL DATA IN MEMORY

You will receive readings only if data has been programmed into one of the personal data memories or the Guest mode. The monitor can store personal details for up to 4 people.

1. Turn on the Power

Press the Set button to turn on the unit (once programmed, tapping a Personal Key turns on the unit.) The unit will beep to confirm activation, the Personal Key numbers (1,2,3,4) will be displayed, and the display will flash.

Note: If you don’t operate the unit for sixty seconds after the unit has been turned on, the unit will turn off automatically.

Note: If you make a mistake or want to turn the unit off before you have finished

programming it, press the Weight-Only Key ( ) to force quit.

2. Select a Personal Key Number

Press the Up/Down buttons to select a Personal Key. Once you reach the Personal Key number you wish to use, press the Set button. The unit will beep once to confirm.

Heels centered on

Toes may overhang

electrodes

measuring platform

Note: An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a sitting position.

To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on the measuring platform. Be sure that your heels are correctly aligned with the electrodes on the measuring platform. Don't worry if your feet appear too large for the unit accurate readings can still be obtained if your toes overhang the platform. It is best to take readings at the same time of day. Try to wait about three hours after rising, eating, or hard exercise before taking measurements. While readings taken under other conditions may not have the same absolute values, they are accurate for determining the percentage of change as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat percentage taken under the same conditions over a period of time.

3. Set Age

The display defaults to Age 30 (range of user age is between 7-99). An arrow icon appears on the lower left side to indicate Age setting. Use the Up/Down buttons to scroll through numbers. When you reach your age, press the Set button. The unit will beep once to confirm.

4. Select Female or Male

Use the Up/Down buttons to scroll through Female ( ) or Male ( ), Female/Athlete and Male/Athlete settings, then press the Set button. The unit will beep once to confirm.

AUTOMATIC SHUT-DOWN FUNCTION

The automatic shut-down function shuts off the power automatically in the following cases:

If you interrupt the measurement process. The power will shut down automatically within 10 to 20 seconds. depending upon the type of operation.

If an extreme weight is applied to the platform.

During programming, if you do not touch any of the keys or buttons within 60 seconds.* After you have completed the measuring process.

*Note: If the power shuts off automatically, repeat the steps from “Setting and Storing Personal Data in Memory” (p.3).

2

5. Specify the Height

The display defaults to 5’ 7.0” (170cm) (range of user is from 3’ 4.0”–7’

3.0” or 100cm – 220cm). Use the Up/Down buttons to specify Height and then press the Set button. The unit will beep once to confirm.

The unit will beep twice and the display will flash all data (Male/Female, Age, Height, etc.) three times to confirm the programming. The power will then shut down automatically.

3

Image 3
Contents Lire attentivement et à garder en cas de besoin Model BC-554Features and Functions Safety PrecautionsImportant Notes for Users Preparations Before USE Getting Accurate ReadingsAutomatic SHUT-DOWN Function Taking Body Composition Readings Programming the Guest ModeTaking Weight Measurement only Trouble ShootingSO Erhalten SIE Genaue Messwerte Merkmale UND Funktionen Vorbereitungen VOR GebrauchEinstellung UND Speichern Persönlicher Daten Messung DER KörperzusammensetzungPersönliche Taste wählen und auf die Waage steigen Caractéristiquesn Einprogrammieren DES GastmodusNUR-GEWICHT-FUNKTION FehlersucheAvant Utilisation Commutation DU Mode Poids Comment Obtenir DES Résultats ExactsFonction D’ARRÊT Automatique Dépannage Programmation DU Mode InvitéRelevés DE Composition Corporelle Lecture DU Poids UniquementAutomatische Unitschakelfunctie Introductie VoorbereidingsmaatregelenEigenschappen EN Functies AfleesnauwkeurighidVeranderen VAN Gewichtseenheid Gaststand Orogrammeren FoutopsporingIntroduzione Funzione DI Spegnimento Automatico Rilevamento DI Varori AccuratiMisurazione DEL SOLO-PESO Risoluzione DEI ProblemiFunción DE Apagado Automático Introducción Preparaciones Antes DEL USOCómo Obtener Lecturas Exactas Prestaciones Y FuncionesCómo obtener las lecturas. Proceso de display automático Cambiando EL Modo DEL PesoEncendido de la unidad Pulse la tecla Personal y párese sobre el monitorCaracterísticas E Funções Programación DEL Modo DE InvitadoCómo Obtener Lecturas DE Peso Solamente IntroduçãoDicas de manuseio Preparativos Antes do USOFunçào Desligamento Automàtico Colocando as pilhasLocalizando Defeitos Efectuar Leituras DE Composição CorporalProgramando Modo Convidado Somente a Leitura do Peso