On the Global and Max modems two dip switches are provided for the selection of the desired operating mode and two plug links are provided from the selection of 2 or 4 wire RS485 operation. A further DIP switch is provided on the Global modem for frequency Channel selection.
| Switch Number | Function | 
| 
 | 
 | 
| 1 | Baud Rate (See Table) | 
| 
 | 
 | 
| 2 | Baud Rate (See Table) | 
| 
 | 
 | 
| 3 | 8 or 9 bit data (Off =  | 
| 
 | ( excluding 1 start and stop bit) | 
| 
 | 
 | 
| 4 | Spare | 
| 
 | 
 | 
| 5 | Spare | 
| 
 | 
 | 
| 6 | Spare | 
| 
 | 
 | 
| 7 | Spare | 
| 
 | 
 | 
| 8 | Test Mode ( Off = Run, on = Test mode) | 
| 
 | 
 | 
| Data Format Mode switch function SW1 | |
| Switch Number | 
 | Function | 
| 
 | 
 | 
 | 
| 1 | 
 | Spare | 
| 
 | 
 | 
 | 
| 2 | 
 | Spare | 
| 
 | 
 | 
 | 
| 3 | 
 | On = RS485 / RS422 | 
| 
 | 
 | 
 | 
| 4 | 
 | On = RS232 | 
| 
 | 
 | 
 | 
| 
 | Interface Mode switch SW2 | |
Note: The Europa is fully electronically programmable. Europa users should consult the programming toll on the disk provided with the modem.
Mode SW1,1
Off
Mode SW1,2
Off
Data Rate
2400 bps
| On | Off | 4800 bps | 
| Off | On | 9600bps | 
| On | On | 19200bps | 
Date rate setting table subject to version constraints listed above.
Test mode is provided exclusively to assist installation. Whenever test mode is selected the modem will produce a test transmission to aid both antenna alignment and propagation tests. Effectively the modem transmits a string of data at your desired data rate. This data message usually " 