TROUBLESHOOTING

Condition

Solution

Poor contact

Clean contact parts thoroughly

Battery voltage is

Start the engine to recharge the

too low

battery. Replace the battery if

 

needed.

Shutdown on

Reduce the wattage of inverter’s load

overload

 

Thermal shutdown

Allow the inverter to cool down by

 

reducing the load or turn it off for a

 

while.

Receptacle has no

Check the receptacle wiring.

power

 

MAINTENANCE

Very little maintenance is required to keep the inverter operating properly.

DESCRIPTION

500W Peak Power — allow you to power appliances that require a large amount of initial (peak) power to work (such as many TVs and motor-power equipments).

Low Battery Alarm — the inverter sounds an audible alarm then turns itself off if the source battery becomes too low.

Auto Shutdown/Reset Protection — the inverter temporarily shuts itself down to protect itself from overheating.

Overload/Short Circuit Protection — the inverter automatically turns itself off if the connected load is too high or if it shorts.

Fuse — the inverter comes with fuse/s already installed and easily changed if it is damaged.

Dual AC Outlets — allows you to power up to two appliances at the same time.

HEAT DISPERSAL

The inverter generates heat while it is working. This is not a malfunction. However, if the inverter gets too hot while working, it will turn off by itself.

Position the inverter where air flows freely around it to allow the heat to disperse.

The inverter’s thermal protection prevents it from operating when its temperature exceeds 130 ± 10 θF / 55

± 5 θC

SPECIFICATION

Name

Description

Input

12V (10-15V) DC

Output

115V AC

Output frequency

60 Hz

Output waveform

Modified Sine Waveform

Continuous power

175 Watt

Surge power

500 Watt

Efficiency

Approx. 90 %

No load current

< 0.2 A

Battery low alarm

10.5 ± 0.5 V DC

Battery low shutdown

10 ± 0.5 V DC

Alarm and thermal

130 ± 10 θF / 55 ± 5 θC

shutdown

 

DC fuse

15 A

AC output socket

2 outlets of 3-prong

Power switch

DC input ON/OFF control

Dimensions

5x4.5x2 in

Net Weight

1 lb

NOTE

All specifications are typical at nominal line, half load, and 25 θC unless otherwise noted. Specification subject to change without notice.